Chapter 5: Advanced Serverboard Setup
5-21
5-20
S
UPER
S
ERVER 6018R-TDTP/TDTPR User's Manual
BMC Enable/Disable
Jumper JPB1 allows you to enable the
embedded Aspeed AST2400 Base-
board Management Controller (BMC) to
provide IPMI 2.0/KVM support on the
serverboard. See the table on the right
for jumper settings.
BMC IPMI Enable/Disable
Jumper Settings
Settings Definition
Pins 1-2
Enabled
Pins 2-3
Disabled
Watch Dog Enable
Watch Dog is a system monitor that can
reboot the system when a software ap-
plication hangs. Close pins 1-2 to reset
the system if an application hangs. Close
pins 2-3 to generate a non-maskable
interrupt signal for the application that
hangs. See the table on the right for
jumper settings. Watch Dog must also be
enabled in the BIOS.
Watch Dog
Jumper Settings
Jumper Setting Definition
Pins 1-2
Reset (default)
Pins 2-3
NMI
Open
Disabled
5-10 Onboard Indicators
SFP+/LAN1/LAN2 LEDs
The SFP+/LAN 1 Activity LED is locat-
ed at LED3, and SFP+/LAN 2 Activity
LED is located at LED5. When LED3
is blinking, SFP+/LAN1 is active. When
LED5 is blinking, SFP+/LAN2 is active.
See the table on the right.
IPMI Dedicated LAN
In addition to the LAN ports, a dedicated
IPMI LAN port is also included on the
X10DRD-LTP. The amber LED on the
right indicates activity, while the green
LED on the left indicates the speed of
the connection. See the table at right for
more information.
BMC Heartbeat LED
A BMC Heartbeat LED is located at
LEDM1 on the serverboard. When
LEDM1 is blinking, the BMC is function-
ing normally. See the table at right for
more information.
BMC Heartbeat
LED Status
Color/State Definition
Green:
Blinking
BMC:
Normal
SFP+/LAN 1/2 Enable/Disable
JPL1 enables or disables the 10Gb
SFP+/LAN ports. See the table on the
right for jumper settings.
SFP+/LAN 1/2 Enable
Jumper Settings
Jumper Setting Definition
Pins 1-2
Enabled)
Pins 2-3
Disabled
Manufacturer Mode Select
Close pins 2 and 3 of JPME2 to bypass
SPI flash security and force the system to
operate in the manufacturer mode, which
will allow the user to flash the system
firmware from a host server for system
setting modifications.
ME Mode Select
Jumper Settings
Jumper Setting Definition
Pins 1-2
Normal (Default)
Pins 2-3
Manufacture Mode
I
2
C Bus to PCI-Express Slots
Use Jumpers JI
2
C1 and JI
2
C2 to connect
the System Management Bus (I
2
C) to
PCI-Express slots to improve PCI perfor-
mance. These two jumpers should be set
at the same time. See the table on the
right for jumper settings.
I
2
C for PCI-E slots
Jumper Settings
Jumper Setting Definition
Pins 1-2
Enabled
Pins 2-3
Disabled
IPMI LAN Link LED (Left) &
Activity LED (Right)
Color/State Definition
Link (Left)
Green: Solid
Amber: Solid
100 Mbps
1 Gbps
Activity
(Right)
Amber: Blink-
ing
Active
SFP+/LAN 1 & 2
Activity LEDs Status
Color/State Definition
LED3:
Green: Blinking
SFP+/LAN1:
Active
LED5:
Green: Blinking
SFP+/LAN2:
Active
SFP+/LAN 1/2 Heartbeat LEDs
The SFP+/LAN 1 Heartbeat LED is
located at LED4, and SFP+/LAN 2
Heartbeat LED is located at LED6 on
the serverboard. When LED4 is blink-
ing, SFP+/LAN1 is working properly.
When LED6 is blinking, SFP+/LAN2 is
working properly. See the table on the
right for more information.
SFP+/LAN 1 & 2
Heartbeat LEDs Status
Color/State Definition
LED4:
Green: Blinking
SFP+/LAN1:
Normal
LED6:
Green: Blinking
SFP+/LAN2:
Normal
Содержание SUPERSERVER 6018R-TDTP
Страница 1: ...SUPERSERVER 6018R TDTP 6018R TDTPR USER S MANUAL 1 0a...
Страница 9: ...1 6 SUPERSERVER 6018R TDTP TDTPR User s Manual Notes...
Страница 14: ...2 8 SUPERSERVER 6018R TDTP TDTPR User s Manual Notes...
Страница 42: ...5 26 SUPERSERVER 6018R TDTP TDTPR User s Manual Notes...
Страница 49: ...6 12 SUPERSERVER 6018R TDTP TDTPR User s Manual Notes...
Страница 70: ...7 40 SUPERSERVER 6018R TDTP TDTPR User s Manual Notes...
Страница 72: ...A 2 SUPERSERVER 6018R TDTP TDTPR User s Manual Notes...
Страница 75: ...B 4 SUPERSERVER 6018R TDTP TDTPR User s Manual Notes...