System Cooling
Four 8-cm fans circulate air through the chassis to lower the internal temperature. The system
fans are designed to be easily changed, with no tools required and no need to remove any
other parts inside the chassis. See Figure 3-2 to determine which nodes and hard drives are
cooled by each fan.
Replacing a System Fan
1. Determine which fan must be replaced. Use IPMI or open the chassis top cover while
the system is operating and observe. Do not run the server for an extended period of
time with the top cover open.
2. Remove the failed fan's power cord from the backplane.
3. Simultaneously squeeze both release tabs on the top of the fan module.
4. Lift the fan module up and out of the chassis.
5. Place the replacement fan into the vacant space in the fan bracket while making sure
the arrows on the top of the fan (indicating air direction) point in the same direction as
the arrows on the other fans.
6. Put the fan back into the chassis and reconnect the cable.
7.
Confirm that the fan is working properly before replacing the chassis cover.
Figure 3-12. Replacing a Fan
Release Tabs