Power Supply
Model: PWS-2K04F-1R, 80+ level Titanium
Total Output Power: 1000W/1800W/1980W/2000W
AC Input Voltages: 100-127 V, 200-220 V, 220-230 V, 230-240 V, 200-240V
Rated Input Frequency: 50-60 Hz
Rated Output Power:
12V
Max.: 83.3A & Min..: 0A (100Vac-127Vac)
Max.: 150A & Min.: 0A (200Vac-220Vac)
Max.: 165A & Min.: 0A (220Vac-230Vac)
Max.: 166.7A & Min.: 0A (230Vac-240Vac)
Max.: 166.7A & Min.: 0A (200Vac-240Vac)
5V SB:
Max.: 1A / Min.: 0A
Output Type:
27 Pairs Gold Finger Connector
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/3-3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,
EN 61000-4-8, EN 61000-4-11)
Environmental: Directive 2011/65/EU, Deligated Directive (EU) 2015/863,and Directive 2012/19/EU
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe)
Perchlorate Warning
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products