Chapter 2: Server Installation
2-5
Installing the Rack Rails
Determine where you want to place the SuperServer 5018D-MTLN4F in the rack
(see Rack and Server Precautions in Section 2-3). Position the chassis rail guides
at the desired location in the rack, keeping the sliding rail guide facing the inside
of the rack. Screw the assembly securely to the rack using the brackets provided.
Attach the other assembly to the other side of the rack, making sure that both are
at the exact same height and with the rail guides facing inward.
Figure 2-1. Installing Rear Inner Chassis Rails
Warning:
do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.