MECI
The Multiple Event Count Increment (MECI) counter counts the number of oc-
curences. A duplicate event must happen before the MECI counter is incremented.
This is a numeric value. The default value is
1
.
METW
Use the Multiple Event Time Window (METW) to define the length of time (in minute)
it must pass before a duplicate log event entry is generated. Enter a number from
0 to 99. The default value is
60 (minutes)
.
View SMBIOS Event Log
This section displays the contents of the SMBIOS Event Log.