background image

USER’S MANUAL 

Revision 1.0a

SuperServer

®

220U-MTNR

Содержание SuperServer 220U-MTNR

Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 220U MTNR...

Страница 2: ...ss A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s in...

Страница 3: ...s and utilities https www supermicro com wdl Product safety info https www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support sup...

Страница 4: ...sion Slots and Riser Cards 15 LAN Speed Indicator 15 Top View 16 1 3 System Architecture 17 Main Components 17 System Block Diagram 18 1 4 Motherboard Layout 19 Quick Reference 20 Motherboard Block Di...

Страница 5: ...e PHM from the CPU Socket 41 Removing the Processor Carrier Assembly from the PHM 42 Removing the Processor from the Carrier Assembly 43 3 4 Memory 44 Memory Support 44 Guidelines Regarding Mixing DIM...

Страница 6: ...Software 5 1 Microsoft Windows OS Installation 74 5 2 Driver Installation 76 5 3 SuperDoctor 5 77 5 4 BMC 78 BMC ADMIN User Password 78 Chapter 6 Optional Components 6 1 Storage Protocols Supported 7...

Страница 7: ...Becomes Unstable 102 7 4 POST Codes 104 7 5 Crash Dump Using the BMC Dashboard 104 7 6 UEFI BIOS Recovery 105 Overview 105 Recovering the UEFI BIOS Image 105 Recovering the Main BIOS Block with a USB...

Страница 8: ...Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technic...

Страница 9: ...Support Six hot swap 2 5 SATA SAS NVMe hybrid drive bays Two SuperDOM disk on modules Expansion Slots Eight PCIe 4 0 Five x8 full height 10 5 One x16 full height 10 5 One x16 low profile One internal...

Страница 10: ...16 Internal PCIe 4 0 x8 in x16 PCIe 4 0 x16 WIO Riser Cards Several customer choices are available for other riser cards See the Expansion Slots and Riser Cards section in this chapter for details Sto...

Страница 11: ...s Each drive carrier has two LED indicators an activity indicator and a status indicator For RAID configurations using a controller the meaning of the status indicator is described in the table below...

Страница 12: ...Fault detected HDD LED Indicates activity on the storage drives when flashing NIC LED Indicates network activity on LANs when flashing Power Fail LED Indicates a power supply module has failed Informa...

Страница 13: ...solid with Power LED blinking green Fault detected Blue and red blinking at 10 Hz Recovery mode Blue solid UID has been activated locally to locate the server in a rack environment Blue blinking at 1H...

Страница 14: ...ial port VGA Video port Power Supplies USB Ports BMC LAN VGA COM UID LED BMC Reset 1 0 4 3 5 6 8 7 2 Power Supply Indicator LEDs on the power supplies indicate the status of the module Power Supply In...

Страница 15: ...ion all PCIe 4 0 Ultra Riser card AOC 2UR668G4 1 2 3 x16 FH 10 5 L 75W CPU2 x16 FH 10 5 L 75W CPU2 x8 in x16 Internal LP 75W CPU1 AOC 2UR68G4 i2XT AOC 2UR68G4 i4XTS AOC 2UR68G4 m2TS 1 2 3 x16 FH 10 5...

Страница 16: ...al redundant modules see options on a previous page SATADOM ports Two Disk on Module ports allows for flash cards to be mounted directly on the motherboard DIMM slots 32 memory slots Processors Dual I...

Страница 17: ...locations of the system electrical components and a block diagram of the overall system Main Components Figure 1 5 Main Component Locations Storage Backplane BPN NVME4 HE211N S6 Ultra Riser Card opti...

Страница 18: ...ocessor CPU2 Options of Ultra Riser Card No NIC Riser 1 INT PCI E 4 0 x8 in x16 Slot CPU1 2 PCI E 4 0 x16 Slots CPU2 2 10GBaseT 2 10G SFP Riser NIC CPU1 1 PCI E 4 0 x16 Slot CPU2 1 PCI E 4 0 x8 in x16...

Страница 19: ...P2 DIMMD2 P2 DIMMD1 P2 DIMMB2 P2_NVMe10 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2_NVMe9 BP PWR2 BP PWR3 BP PWR4 NVME7 P1 DIMMC2 P1 DIMMD2 P1 DIMMC1 P1 DIMMD1 P1 DIMMA2 P1 DIMMA1 P1 DIMMB2 P1 DIMMB1 P1 DIMMF1 P...

Страница 20: ...VPP 2 JGPW1 JGPW2 JGPW3 JGPW4 GPU 8 pin power connectors power connectors for GPU use JPW1 JPW2 JPW3 JPW4 Backplane 8 pin power connectors for backplane devices JUIDB UID LED BMC Reset switch JVGA2 Fr...

Страница 21: ...MM 2 1 DDR4 DIMM 2 1 DDR4 DIMM DDR4 2 1 VGA UART DDR4 DIMM 2 1 64GB s PCH SATA Gen3 4 7 S SATA5 S SATA4 sSATA Gen3 0 3 JS1 JS3 sSATA Gen3 4 5 DMI USB3 0 0 1 3 4 SPI LPC eSPI TPM Header HWM USB SPI MUX...

Страница 22: ...be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated It will also require a grounded AC power outlet nearby Be...

Страница 23: ...the electrical and general safety precautions in Appendix A Determine the placement of each component in the rack before you install the rails Install the heaviest server components at the bottom of t...

Страница 24: ...be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connections other than the direct connections to the branch circuit i...

Страница 25: ...installation instructions that came with the specific rack you are using Identifying the Rails The chassis package includes two rail assemblies Each assembly consists of three sections An inner rail t...

Страница 26: ...tely out of the rack when when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails 1 Pull the inner rail out of the outer rail...

Страница 27: ...against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the quick release br...

Страница 28: ...il adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the square holes on the rear of the rack Take care that the proper h...

Страница 29: ...Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely...

Страница 30: ...Be sure to have sufficient assistance supporting the chassis when removing it from the rack Use a lift 1 If necessary loosen the thumb screws on the front of the chassis that hold it in the rack 2 Pu...

Страница 31: ...Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installi...

Страница 32: ...which secure the cover to the chassis 2 Lift the locking latch then slide the cover toward the rear and lift off Check that all ventilation openings on the top cover and the top of the chassis are cle...

Страница 33: ...Use the key to unlock the bezel from the chassis 2 Press the red lever and pull the bezel off Replacing the Bezel 1 Insert the two mounting pins on the left of the bezel into the holes in the tab on...

Страница 34: ...hat the plastic protective cover is on the CPU socket and that none of the socket pins are bent If they are contact your retailer When handling the processor avoid touching or placing direct pressure...

Страница 35: ...down Locate the gold triangle at the corner of the processor and the corresponding hollowed triangle on the processor carrier as shown below These triangles indicate the location of pin 1 Latch Latch...

Страница 36: ...of the processor under latch 1 on the carrier and then press the other end down until it snaps into latch 2 and is properly seated on the carrier Processor Carrier Assembly Top View Processor Carrier...

Страница 37: ...the heatsink over with the thermal grease facing up Note the two triangle cutouts A B located at the diagonal corners of the heatsink as shown in the drawing below 2 On the processor carrier assembly...

Страница 38: ...nd Component Installation Installing the PHM into the CPU Socket 1 Remove the plastic protective cover from the CPU socket Gently squeeze the grip tabs then pull the cover off CPU Socket with Plastic...

Страница 39: ...asteners a b c d on the CPU socket 3 Locate four PEEK nuts A B C D and four rotating wires 1 2 3 4 on the heatsink as shown below 4 Check that the rotating wires 1 2 3 4 are in the unlatched position...

Страница 40: ...sink on the CPU socket making sure that each nut is properly aligned with its corresponding threaded fastener Latched State Top View 7 Press all four rotating wires outward to latch the PHM onto the C...

Страница 41: ...CPU Socket Be sure the system is shut down and all AC power cords are unplugged 1 Use a t30 bit screwdriver to loosen the four PEEK nuts on the heatsink in the sequence of A B C and D 2 Press the four...

Страница 42: ...r Carrier Assembly from the PHM Detach the four plastic clips a b c d on the processor carrier assembly from the four corners of the heatsink A B C D as shown below and lift off the processor carrier...

Страница 43: ...the Carrier Assembly Unlock the lever from its locked position and push it upwards to disengage the processor from the carrier as shown below right Carefully remove the processor from the carrier Proc...

Страница 44: ...IPMI CODE X12DPU 6 FAN2 NVME4 NVME5 NVME6 NVME9 NVME1 SXB3_3 SXB2 JTPM1 JNCSI1 BT1 FAN7 FAN6 FAN5 FAN4 FAN3 FAN2 T SGPIO3 JPW2 JPW1 JGPW1 JGPW2 JRK1 JLAN1 JBT1 JUIDB2 JUSB3 SXB3_1 SXB1_1 SXB1_3 PSU1...

Страница 45: ...s Mixing of non 3DS and 3DS LRDIMM is not allowed in the same channel across different channels and across different sockets Mixing of PMem modules and RDIMMs is supported Mixing DDR4 and PMem memory...

Страница 46: ...B1 C1 D1 E1 F1 G1 H1 CPU2 A1 B1 C1 D1 E1 F1 G1 H1 2 CPUs 18 DIMMs CPU1 A1 A2 B1 C1 C2 D1 E1 E2 F1 G1 G2 H1 CPU2 A1 B1 C1 E1 F1 G1 2 CPUs 20 DIMMs CPU1 A1 A2 B1 C1 C2 D1 E1 E2 F1 G1 G2 H1 CPU2 A1 B1 C1...

Страница 47: ...DDR4 DDR4 DDR4 DDR4 DDR4 PM DDR4 DDR4 PM DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 DDR4 PM DDR4 DDR4 DDR4 DDR4 DDR4 8 DDR4 4 PMem AD MM 1 x4 DDR4 DDR4 PM DDR4 DDR4 PM PM DDR4 DDR4 PM DDR4 DDR4 2 x...

Страница 48: ...timized PMem to DRAM cache ratio in MM and MM AD modes For each individual population different PMem rearrangements among channels are permitted so long as the configuration does not break X12 DP Memo...

Страница 49: ...power from the system as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release T...

Страница 50: ...the motherboard Replacing the Battery Begin by removing power from the system 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the holder 2...

Страница 51: ...rts six hot swap 2 5 storage drives in hybrid bays SATA support is default SAS support can be afforded with an optional controller card and cables NVMe support also requires additional cables For comp...

Страница 52: ...ve carrier with the disk drive into its bay keeping the carrier oriented so that the release button is on the right side When the carrier reaches the rear of the bay the release handle will retract 4...

Страница 53: ...s support NVMe surprise hot swap For even better data security NVMe orderly hot swap is recommended NVMe drives can be ejected and replaced remotely using the BMC Dashboard Note If you are using VROC...

Страница 54: ...th a failed fan although it may shut down if the heat gets too great Replace any failed fan at your earliest convenience with the same model Failed fans can be identified through the BMC Changing a Sy...

Страница 55: ...re 3 10 Installing the Standard Air Shrouds Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency They do not require screws to install Installing the Standard Air Shrouds Position th...

Страница 56: ...hen illuminated indicates that the power supply is on Blinking Green When blinking indicates that the power supply is plugged in and turned off by the system Blinking Amber When blinking indicates tha...

Страница 57: ...L 75W CPU2 x8 in x16 FH 10 5 L 75W CPU2 x8 in x16 Internal LP 75W CPU2 Right facing RSC WR 6 4 x16 low profile 75W CPU1 Left facing RSC W2 8888G4 5 6 7 8 x8 FH 10 5 L CPU2 x8 FH 10 5 L 25W 25W CPU2 x...

Страница 58: ...tic flip lever with an arrow on it Flip open the appropriate lever to release the bracket then pull the bracket out of the chassis 3 Insert the expansion card s into the riser card slot s while aligni...

Страница 59: ...ry remove the full height expansion card to access the low profile riser card slot pictured above 3 Insert the expansion card into the riser card slot while aligning the rear PCI shield into the chass...

Страница 60: ...lso offers another internal low profile card slot 3 Installation is pictured below See previous procedures for details to access the riser card and bracket View from Rear of Chassis View from Front of...

Страница 61: ...ion Cards with Optional Storage Drives This server supports an option to add two storage drives in place of expansion cards Optional Cage for Two Storage Drives View from Front of Chassis View from Re...

Страница 62: ...outing is important to maintain airflow through the system SAS cable routing depends on the model and position of the SAS controller card so routing is not shown here Online Cable Matrix Backplane Pow...

Страница 63: ...ector Two proprietary main power headers are located at PSU1 and PSU2 Connect appropriate power supply units to these two headers to provide adequate power to your system Important To provide adequate...

Страница 64: ...Pin Definition 1 Ground Black 2 12V Red 3 Tachometer 4 PWM Control SGPIO Header A Serial General Purpose Input Output header T SGPIO3 is used to communicate with the enclosure management chip on the b...

Страница 65: ...finitions Pin Definition Pin Definition 1 P3V3 2 SPI_TPM_CS_N 3 PCIe_RESET_N 4 SPI_PCH_MISO 5 SPI_PCH_CLK 6 Ground 7 SPI_PCH_MOSI 8 N A 9 JTPM1_P3V3A 10 IRQ_TPM_SPIN_N NVMe SMBus Headers NVMe SMBus I2...

Страница 66: ...oard may look different 4 pin BMC External I2 C Header A System Management Bus header for the BMC is located at JIPMB1 Connect a cable to this header to use the IPMB I2 C connection on your system Ext...

Страница 67: ...ll power on off the system This button can also be configured to function as a suspend button with a setting in the UEFI BIOS To turn off the power when the system is in suspend mode press the button...

Страница 68: ...LED 8 OH Fan Fail LED NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Controller LED connection for LAN port 1 is located on pins 11 and 12 of JF1 and the LED connection for LAN port 2 is on pins 9 and...

Страница 69: ...nection is located on pins 15 and 16 of JF1 Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Power LED NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 NM...

Страница 70: ...by the Ultra riser card depending on the option you purchased Unit Identifier Switch UID LED Indicator A Unit Identifier UID switch and a UID LED indicator are located on the rear of the system When...

Страница 71: ...g function Watchdog is a monitor that can reboot the system when a software application hangs Jumping pins 1 2 will cause Watch Dog to reset the system if an application hangs Jumping pins 2 3 will ge...

Страница 72: ...is functioning normally 4 5 LED Indicators Network LAN LEDs The Ethernet ports each have two LEDs One LED indicates activity when flashing green The other may be green amber or off to indicate the sp...

Страница 73: ...ot require external power cables Supermicro SuperDOMs are compatible with regular SATA HDDs or SATA DOMs that need external power cables NVMe Connectors The motherboard offers the following NVMe heade...

Страница 74: ...supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive...

Страница 75: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...

Страница 76: ...Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or...

Страница 77: ...etwork Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SS...

Страница 78: ...our website at www supermicro com en solutions management software bmc resources BMC ADMIN User Password For security each system is assigned a unique default BMC password for the ADMIN user This can...

Страница 79: ...ional hardware is required Once the supporting hardware is installed for a selection of bays drives of any storage protocol type can be inserted SATA The default configuration supports up to twelve SA...

Страница 80: ...front of the rack for maintenance The CMA attaches to the rack mounting rails by means of four connectors They are labeled on the connectors 1 2 3 and 4 Installing the Cable Management Arm 1 Slide CM...

Страница 81: ...r rail and push it forward It snaps into place 5 Route the cables through the holding brackets leaving enough slack 1 2 1 4 3 Removing the Cable Management Arm 1 Remove cables from the CMA 2 For CMA c...

Страница 82: ...to connect a Trusted Platform Module TPM A TPM is a security device that supports encryption and authentication in hard drives It enables the motherboard to deny access if the TPM associated with the...

Страница 83: ...torage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise Intel...

Страница 84: ...ons are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd party SSDs AOC VROCPR...

Страница 85: ...s 2 Switch to Advanced Chipset Configuration North Bridge IIO Configuration Intel VMD Technology Figure 6 7 BIOS Selecting VMD Mode You can select a mode The default is Auto The VMD switch enables VMD...

Страница 86: ...ptional Components Figure 6 8 BIOS Manual Mode Example your server may look different 3 Select the desired PStack to Enable or Disable the corresponding Intel VMD controller Figure 6 9 BIOS Enabling V...

Страница 87: ...apability can also be Enabled or Disabled Figure 6 10 BIOS Enabling VMD Functionality per Slot 5 Repeat steps 3 and 4 for each PStack on each CPU to be enabled or disabled In this example we enabled C...

Страница 88: ...without first deleting the associated existing RAID volume can lead to unexpected behavior This action is strongly not recommended Note The effects of physically changing or swapping a CPU on the VMD...

Страница 89: ...disks RAID1 Select only two disks RAID5 Select at least three 3 24 disks RAID10 Select only four disks 12 Select Strip Size Default 64KB 13 Select Create Volume 14 If another RAID is needed start aga...

Страница 90: ...evice Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s article 215140...

Страница 91: ...e to thermal limitations not all four slots can be filled for some GPU models See Chapter 3 PCI Expansion Cards for details on the various riser card options 6 6 GPUs Supermicro 2U Ultra systems suppo...

Страница 92: ...iate lever to release the bracket then pull the bracket out of the chassis For the Ultra riser center bracket there is a thumbscrew to a standoff in the chassis center 3 Insert the GPU into the riser...

Страница 93: ...side GPUs into the Riser Card Bracket Figure 6 18 Inserting the Middle and Right side GPUs into the Riser Card Bracket Rear L Bracket for Left side GPU Rear L Bracket for Middle GPU Rear L Bracket fo...

Страница 94: ...side GPU a middle GPU or a right side GPU the front bracket is pre installed on the riser card bracket Figure 6 20 Attaching the Front Bracket for Middle and Right side GPUs Bracket for Middle GPU Bra...

Страница 95: ...into the throat of the air shroud Then align and insert the riser card into the motherboard slot while aligning the bracket into the chassis 8 Secure the bracket into the chassis At the chassis rear...

Страница 96: ...96 Chapter 6 Optional Components Figure 6 Air Shroud for use with GPU...

Страница 97: ...MA warranty and other service extensions Direct Links for the 220U MTNR System Web SYS 220U MTNR specifications page X12DPU 6 motherboard page for links to the Quick Reference Guide User Manual valida...

Страница 98: ...ted to the BMC For general documentation and information on the BMC please visit our website at www supermicro com manuals other BMC_Users_Guide_X12_H12 pdf Figure 7 2 BMC Dashboard Sample Product Mat...

Страница 99: ...DIMMF1 P1 DIMMF2 P1 DIMME1 P1 DIMME2 P1 DIMMH1 P1 DIMMH2 P1 DIMMG1 P1 DIMMG2 JPW4 BP PWR1 JPW3 JPB1 JPG1 NVME8 P2_NVMe8 JGPW3 JSD1 JGPW4 GPU PWR3 GPU PWR1 GPU PWR2 GPU PWR4 LE2 No Power Check that th...

Страница 100: ...poor quality power supply may cause the system to lose the CMOS setup information Check that the motherboard battery still supplies 3VDC If it does not replace it If the above steps do not fix the set...

Страница 101: ...ing boot devices Cable connection Check to make sure that all cables are connected and working properly Use the minimum configuration for troubleshooting Remove all unnecessary components starting wit...

Страница 102: ...k the Server Health tab then Event Log to verify an IERR error Figure 7 4 BMC Event Log In the event of an IERR the BMC executes a crash dump You must download the crash dump and save it 7 4 POST Code...

Страница 103: ...ed When the system power is turned on the recovery block codes execute first Once this process is complete the main BIOS code will continue with system initialization and the remaining POST Power On S...

Страница 104: ...he BIOS binary image into a USB flash device and rename it Super ROM for the BIOS recovery use Note 2 Before recovering the main BIOS image confirm that the Super ROM binary image file you download is...

Страница 105: ...s shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrup...

Страница 106: ...EFI Shell prompt appears type fs to change the device directory path Go to the directory that contains the BIOS package you extracted earlier from Step 6 Enter flash nsh BIOSname at the prompt to star...

Страница 107: ...complete When you see the screen above unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 10 Press Del continuously...

Страница 108: ...e system Notes Clearing CMOS will also clear all passwords Do not use the PW_ON connector to clear CMOS JBT1 contact pads 7 8 BMC Reset The BMC can be reset using the UID button Reset Press and hold t...

Страница 109: ...boot block code 3 If you still cannot resolve the problem include the following information when contacting us for technical support System motherboard and chassis model numbers and PCB revision numb...

Страница 110: ...lure due to the alteration misuse abuse or improper maintenance of products During the warranty period contact your distributor first for any product problems Vendor Support Filing System For issues r...

Страница 111: ...om Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support sup...

Страница 112: ...ssistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These wa...

Страница 113: ...idere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el te...

Страница 114: ...dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het...

Страница 115: ...i n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het systeem...

Страница 116: ...del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l installa...

Страница 117: ...g a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre...

Страница 118: ...nt u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to in...

Страница 119: ...lar reemplazar o utilizar este equipo Attention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning...

Страница 120: ...na de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s une...

Страница 121: ...e ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta R...

Страница 122: ...evolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All connec...

Страница 123: ...te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention C...

Страница 124: ...tencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circu...

Страница 125: ...con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden...

Страница 126: ...elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled according...

Страница 127: ...lage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving parts...

Страница 128: ...rnilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient toujo...

Страница 129: ...r CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro UL CSA U...

Страница 130: ...code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto utilic...

Страница 131: ...uitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing of b...

Страница 132: ...can be supported with additional equipment Two SuperDOM Disk on Module headers PCI Expansion Slots One PCIe 4 0 x16 full height 10 5 length Five PCIe 4 0 x8 full height 10 5 length One PCIe 4 0 x16 l...

Страница 133: ...AS NZS CISPR 32 BS EN55032 BS EN55035 CISPR 32 CISPR 24 CISPR 35 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 8 BS EN 6...

Страница 134: ...he Presence Condition of the Restricted Substances Marking Restricted substances and its chemical symbols Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the percentage content of the rest...

Страница 135: ...fications PWS 1K22A 1R 100 127 V 60 50 Hz 9 8 7 A x2 200 240 V 60 50 Hz 7 5 6 A x2 PWS 2K08A 1R 100 127 V 60 50 Hz 12 9 A x2 200 240 V 60 50 Hz 10 9 8 A x2 PWS 1K62A 1R 100 127 V 60 50 Hz 12 9 A x2 20...

Страница 136: ...Condition of the Restricted Substances Marking Restricted substances and its chemical symbols Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the percentage content of the restricted subs...

Страница 137: ...137 Appendix B System Specifications 44 65Vdc 40 27A x2...