SuperServer 2049U-TR4 User's Manual
50
Figure 3-13. Installing the Air Shroud
Air Shroud
Cooling is also improved by installing the standard air shroud. Insert it over the CPUs.
Power Supply
The 2049U-TR4 has a 1600 Watt redundant hot-plug power supply consisting of two power
modules. They have an auto-switching capability, which enables them to automatically sense
and operate at a 100V-240V input voltage.
If either of the two power supply modules fail, the other module will take the full load and
allow the system to continue operation without interruption. The Power Fail LED will illuminate
and remain on until the failed unit has been replaced. Replacement units can be ordered
directly from Supermicro.