SuperServer 2049U-TR4 User's Manual
48
Figure 3-11. Installing a Drive into the Carrier
Drive Carrier LEDs
The chassis includes externally accessible SAS/SATA/NVMe drives. Each drive carrier
displays two status LEDs on the front of the carrier.
LED Color
State
Status
Activity LED
Blue
Solid On
SAS/NVMe drive installed
Blue
Blinking
I/O activity
Status LED
Red
Solid On
Failed drive for SAS/SATA/NVMe with RSTe support
Red
Blinking at 1 Hz
Rebuild drive for SAS/SATA/NVMe with RSTe support
Red
Blinking with two blinks and
one stop at 1 Hz
Hot spare for SAS/SATA/NVMe with RSTe support
Red
On for five seconds, then off
Power on for SAS/SATA/NVMe with RSTe support
Red
Blinking at 4 Hz
Identify drive for SAS/SATA/NVMe with RSTe support
Green
Solid On
Safe to remove NVMe device
Amber
Blinking at 1 Hz
Attention state—do not remove NVMe device
System Cooling
The chassis contains four (4) 8-cm high-performance fans and an air shroud to direct air flow.
Replacing a System Fan
Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining fan will
ramp up to full speed and the overheat/fan fail LED on the control panel will turn on. Replace
any failed fan at your earliest convenience with the same type and model (the system can
continue to run with a failed fan).
Remove the top chassis cover while the system is still running to determine which of the fans
has failed. Then power down the system before replacing a fan. Removing the power cord(s)
is also recommended as a safety precaution.
Содержание SuperServer 2049U-TR4
Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 2049U TR4...
Страница 46: ...SuperServer 2049U TR4 User s Manual 46 1 2 Figure 3 9 Removing a Drive Carrier...
Страница 112: ...112 SuperServer 2049U TR4 User s Manual...
Страница 141: ...Appendix E Traditional Chinese Version of Safety Warnings 141 1 2 3 4 5 1 2 3 4 1 2 3 4 1 2...
Страница 142: ...142 SuperServer 2049U TR4 User s Manual...