3-4
SUPERSERVER 1027R-73DBRF User's Manual
3-4 Drive Carrier LEDs
The chassis includes externally accessible SAS/SATA/NVMe drives. Each drive
carrier displays two status LEDs on the front of the carrier.
LED Color
State
Status
Activity LED
Blue
Solid On
SAS/NVMe drive installed
Blue
Blinking
I/O activity
Status LED
Red
Solid On
Failed drive for SAS/SATA/NVMe with
RSTe support
Red
Blinking at 1 Hz
Rebuild drive for SAS/SATA/NVMe with
RSTe support
Red
Blinking with two blinks
and one stop at 1 Hz
Hot spare for SAS/SATA/NVMe with
RSTe support
Red
On for fi ve seconds,
then off
Power on for SAS/SATA/NVMe with
RSTe support
Red
Blinking at 4 Hz
Identify drive for SAS/SATA/NVMe with
RSTe support
Green
Solid On
Safe to remove NVMe device
Amber
Blinking at 1 Hz
Attention state—do not remove NVMe
device