USER'S MANUAL
Revision 1.0
SuperServer
®
1019GP-TT
Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 1019GP TT...
Страница 2: ...operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may ca...
Страница 3: ...sary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety info...
Страница 4: ...tions 17 Server Precautions 18 Rack Mounting Considerations 18 Ambient Operating Temperature 18 Airflow 18 Mechanical Loading 18 Circuit Overloading 19 Reliable Ground 19 2 3 Installing the Rails 20 I...
Страница 5: ...e CPU Socket 32 Installing the Processor Heatsink Module PHM 33 Removing the Processor Heatsink Module PHM from the Motherboard 34 Memory Support and Installation 35 Memory Support 35 DIMM Module Popu...
Страница 6: ...ws to a Non RAID System 62 5 2 Driver Installation 63 5 3 SuperDoctor 5 64 5 4 IPMI 65 Chapter 6 BIOS 6 1 Introduction 66 6 2 Main Setup 67 6 3 Advanced Setup Configurations 69 6 4 Event Logs 94 6 5 I...
Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...
Страница 8: ...in Appendix B Main Parts List Description Part Number Quantity Air shroud for CPU MCP 310 11808 0N 1 Hard drive backplane BPN SAS 118TQ 1 1U passive CPU heatsink SNK P0067PS 1 Riser card for PCI E x1...
Страница 9: ...3647 Memory Up to 192GB of RDIMM 384GB of LRDIMM and 768GB of 3DS LRDIMM DDR4 ECC memory with speeds of up to 2666 MHz in six memory slots Note Memory speed support depends on the processors used in t...
Страница 10: ...e unit identifier button turns on or off the UID LEDs located on the front and rear of the chassis to help locate the system in a rack 7 Power Button The main power button is used to apply or remove p...
Страница 11: ...front of the chassis Front Chassis Features Item Feature Description 1 Power Supply 1400W power supply 2 Drive Carriers Hot swap 2 5 hard disk drive carriers 3 Control Panel Front control panel with...
Страница 12: ...ure Description 1 GPU Card Slots Slots for add on GPU cards 2x left side 2x right side 2 I O Backpanel Rear I O ports see Section 4 3 for full details 3 PCI Card Slot Slot for one expansion card requi...
Страница 13: ...JPWR6 JUIDB1 JPWR5 JPI2C1 JL1 JOH1 JPME2 JWD1 JPG1 JP1 JPTG1 JPCK1 LE1 LE3 LEDM1 LE2 LE4 FAND FAN1 FAN2 FAN4 FAN3 FANA FANC FANB S SGPIO1 I SGPIO2 JP3 JP2 JBT1 MH12 MH10 JTPM1 JSD2 JSD1 JIPMB1 JNVI2C...
Страница 14: ..._LAN Dedicated IPMI LAN Port I SATA4 I SATA7 Intel PCH SATA 3 0 Ports with RAID 0 1 5 10 I SGPIO1 S SGPIO1 Serial Link General Purpose I O Connection Headers I SGPIO SATA use S SGPIO sSATA use JD1 Spe...
Страница 15: ...r S SATA0 S SATA1 SATA 3 0 ports with SATA DOM Power SXB1A SXB1B Left PCI E 3 0 x16 GPU Slot SXB2A SXB2B Right PCI E 3 0 x16 GPU Slot USB0 USB1 Back Panel Universal Serial Bus USB 2 0 Ports USB2 3 Fro...
Страница 16: ...500 12 15 5 COM2 Header VGA CONN BMC Boot Flash DDR4 5 1 PHASE 205W 2133 2666 DDRIV VR13 C 1 B 1 A 1 Right GPU PCI E X16 G3 PCI E X16 G3 DMI3 SNB CORE DDR IV 3 VCCP0 12v VCCP0 PECI 30 SOCKET ID 0 1 ES...
Страница 17: ...on Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Leave enou...
Страница 18: ...in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep the front door of the rack and all covers panels on the servers closed...
Страница 19: ...ention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit...
Страница 20: ...the right side of the chassis and one for the left Each set consists of an inner rail that is fixed directly to the chassis and an outer rail that attaches to the rack The inner rails are pre attached...
Страница 21: ...s until the quick release bracket snaps into place securing the extension to the chassis 3 If desired you can install a screw to further secure the extension to the chassis 4 Repeat for the other inne...
Страница 22: ...hese brackets must be removed and you must use screws to secure the rail to the rack Outer Rail Installation 1 Align the square pegs on the front end of the rail with the square holes on the front of...
Страница 23: ...ore you slide the unit out for servicing Failure to stabilize the rack can cause the rack to tip over Sliding the Chassis onto the Rack Rails Installing the Chassis into a Rack 1 Align the chassis rai...
Страница 24: ...e two L shaped brackets on either side of the chassis four total First determine how far follow the server will extend out the front of the rack Larger chassis should be positioned to balance the weig...
Страница 25: ...SuperServer 1019GP TT User s Manual 25 Figure 2 6 Installing the Server into a Telco Rack Note Figures are for illustrative purposes only Always install servers to the bottom of a rack first...
Страница 26: ...If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnect the power cord s from the power supply modules 3 2 Accessing the System The SC118GTS...
Страница 27: ...he processor and heatsink should be assembled together first to form the Processor Heatsink Module PHM and then install the entire PHM into the CPU socket When you receive a motherboard without a proc...
Страница 28: ...ssor package carrier used for the CPU Overview of the Processor Socket Assembly The processor socket assembly contains 1 the Intel processor 2 the processor clip 3 the dust cover and 4 the CPU socket...
Страница 29: ...mponent Installation 1 Heatsink 2 Processor Clip 3 Processor Overview of the Processor Heatsink Module PHM The Processor Heatsink Module PHM contains 1 a heatsink 2 a processor clip and 3 the processo...
Страница 30: ...by sliding notch B of the CPU into notch B of the processor clip and sliding notch C of the CPU into notch C of the processor clip 4 Examine all corners of the CPU to ensure that it is properly seated...
Страница 31: ...graphic Note a larger hole and plastic mounting clicks located next to the hollow triangle Also locate another set of mounting clicks and a larger hole at the diagonal corner of the same reverse side...
Страница 32: ...socket and 4 a back plate These components are pre installed on the motherboard before shipping Dusk Cover Socket Pins Remove the dust cover from the CPU socket Do not touch the socket pins Removing...
Страница 33: ...p and you will see a triangle marked on the processor clip at the same corner of hollow triangle 3 Carefully align pin 1 the triangle on the the PHM against pin 1 the triangle on the CPU socket 4 Once...
Страница 34: ...g the processor heatsink module PHM unplug power cord from the power outlet 1 Using a T30 Torx bit screwdriver turn the screws on the PHM counterclockwise to loosen them from the socket starting with...
Страница 35: ...8GB of 3DS LRDIMM ECC DDR4 2666 memory in six memory slots Refer to the table below for additional memory information Type RDIMM RDIMM RDIMM RDIMM RDIMM 3DS LRDIMM 3DS LRDIMM Ranks Per DIMM and Data W...
Страница 36: ...release tabs to the lock positions to secure the DIMM module into the slot DIMM Removal Press both release tabs on the ends of the DIMM module to unlock it Once the DIMM module is loosened remove it f...
Страница 37: ...and removing the cover as described in Section 3 2 1 Remove the riser card bracket from the chassis by unscrewing only those screws indicated by the screwdriver icon as illustrated in Figure 3 5 2 Li...
Страница 38: ...SuperServer 1019GP TT User s Manual 38 Figure 3 5 Installing the Riser and Expansion Cards to the Bracket 1 3 1 4 1 6 Screwdriver Icon 1 1 Riser Card Bracket Riser Card Low Profile Expansion Card...
Страница 39: ...drives are mounted in drive carriers to simplify their installation and removal from the chassis Both procedures may be done without removing power from the system Removing a Hot Swap Drive Carrier 1...
Страница 40: ...ED indicators an activity indicator and a status indicator In RAID configurations the status indicator lights to indicate the status of the drive In non RAID configurations the status indicator remain...
Страница 41: ...push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous materials into the environment...
Страница 42: ...control panel buttons System Fans Eight counter rotating fans provide cooling for the chassis These fans circulate air through the chassis as a means of lowering the chassis internal temperature Each...
Страница 43: ...ove the cover as described in Section 3 2 1 Remove the failed fan s power cable from the backplane 2 Remove the four pins securing the fan to the fan housing 3 Lift the failed fan from the fan housing...
Страница 44: ...he system and check that the fan is working properly before replacing the chassis cover Replacing a System Fan 1 If not using BIOS to determine which fan has failed open the top cover of the chassis w...
Страница 45: ...ower supply unit fails the system will shut down and you will need to replace the unit Replacement units can be ordered directly from Supermicro Replacing the Power Supply 1 If the system is still run...
Страница 46: ...3 before installing or removing components 4 1 Power Connections There are two power connections on the X11SPG TF 20 pin Primary ATX Power JPWR5 8 pin Power Connector for GPU JPWR6 Main ATX Power Con...
Страница 47: ...efinitions Fan Header Pin Definitions Pin Definition 1 Ground Black 2 2 5A 12V Red 3 Tachometer 4 PWM_Control Required Connection 8 pin Power Pin Definitions Pin Definition 1 4 Ground 5 8 P12V 12V Pow...
Страница 48: ...ls other TPM pdf SGPIO Headers There are two Serial Link General Purpose Input Output S SGPIO1 headers located on the motherboard I SGPIO is for SATA use while S SGPIO is for sSATA use SGPIO headers a...
Страница 49: ...to use the IPMB I2 C connection on your system Refer to the table below for pin definitions Standby Power The Standby Power header is located at JSTBY1 on the motherboard You must have a card with a S...
Страница 50: ...ndication and pins 4 7 are for the speaker Please note that the speaker connector pins 4 7 are used with an external speaker If you wish to use the onboard speaker you should close pins 6 7 with a cap...
Страница 51: ...UID LED will be turned on Press the UID switch again to turn off the LED indicator The UID Indicator provides easy identification of a system unit that may be in need of service Note UID can also be...
Страница 52: ...connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configured to function as a suspend button with a setting in the BIOS...
Страница 53: ...F1 Refer to the table below for pin definitions Power Fail LED Pin Definitions JF1 Pin Definition 5 3 3V 6 PWR Supply Fail NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Controller LED connection for L...
Страница 54: ...fer to the table below for pin definitions Power LED Pin Definitions JF1 Pins Definition 15 3 3V 16 PWR LED NMI Button The non maskable interrupt NMI button header is located on pins 19 and 20 of JF1...
Страница 55: ...scription 1 Dedicated IPMI LAN 4 LAN1 7 USB1 2 USB5 3 0 5 LAN2 8 VGA Port 3 USB4 3 0 6 USB0 9 UID Switch LAN Ports Two Gigabit Ethernet ports LAN1 LAN2 are located on the I O back panel In addition a...
Страница 56: ...X B5 USB3_RN A6 Stda_SSRX B6 USB3_RP A7 GND B7 GND A8 Stda_SSTX B8 USB3_TN A9 Stda_SSTX B9 USB3_TP Back Panel USB 0 1 2 0 Pin Definitions Pin Definition Pin Definition 1 5V 5 5V 2 USB_N 6 USB_N 3 USB_...
Страница 57: ...D switch the UID LED will be turned on Press the UID switch again to turn off the LED indicator The UID Indicator provides easy identification of a system unit that may be in need of service Note UID...
Страница 58: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cleari...
Страница 59: ...is Reset Note When Watch Dog is enabled the user needs to write a separate application software to disable it Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset Pins 2 3 NMI Open Disab...
Страница 60: ...near the UID switch on the I O back panel This UID indicator provides easy identification of a system unit that may need service IPMI LAN LEDs In addition to LAN1 and LAN2 an IPMI LAN is also located...
Страница 61: ...installing components Refer to the table below for more information Onboard Power LED Indicator LED Color Definition Off System Off power cable not connected Green System On BMC Heartbeat LED A BMC He...
Страница 62: ...port on the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper driv...
Страница 63: ...er option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities to your hard dr...
Страница 64: ...agement Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server y...
Страница 65: ...orm Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and information on IPMI...
Страница 66: ...F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be confi...
Страница 67: ...light System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The t...
Страница 68: ...Server 1019GP TT User s Manual CPLD Version This item displays the Complex Programmable Logic Device version Memory Information Total Memory This item displays the total size of memory available in th...
Страница 69: ...to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST mess...
Страница 70: ...ot and EFI Boot Install Windows 7 USB Support Enable this feature to use the USB keyboard and mouse during the Windows 7 installation since the native XHCI driver support is unavailable Use a SATA opt...
Страница 71: ...ride Throttle on Power Fail Use this feature to decrease system power by throttling CPU frequency when one power supply has failed The options are Disabled and Enabled CPU Configuration The following...
Страница 72: ...emory to the L2 cache to improve CPU performance The options are Disable and Enable Adjacent Cache Prefetch Available when supported by the CPU The CPU prefetches the cache line for 64 bytes if this f...
Страница 73: ...played ENERGY_PERF_BIAS_CFG Mode The Energy Perfomance BIAS EPB feature allows the user to configure CPU power and perfomance settings Select Maximum Performance to set the highest performance Select...
Страница 74: ...setting allows the user to select between OS and hardware controlled P states Selecting Native Mode allows the OS to choose a P state Selecting Out of Band Mode allows the hardware to autonomously ch...
Страница 75: ...following features may cause the system to malfunc tion North Bridge This feature allows the user to configure the following North Bridge settings UPI Configuration The following UPI information will...
Страница 76: ...ory controller Enabling SNC improves average latency and reduces memory access conges tion to achieve higher performance Select Auto for 1 cluster or 2 clusters depending on IMC interleave Select Enab...
Страница 77: ...ming The options are POR and Disable Memory Frequency Use this feature to set the maximum memory frequency for onboard memory modules The options are Auto 1866 2000 2133 2200 2400 2600 and 2666 Data S...
Страница 78: ...ation of onboard memory modules as detected by the BIOS Memory RAS Configuration Static Virtual Lockstep Mode Select Enable to run the system s memory channels in lockstep mode to minimize memory acce...
Страница 79: ...nable the IO hub will read and write back one cache line every 16K cycles if there is no delay caused by internal processing By using this method roughly 64 GB of memory behind the IO hub will be scru...
Страница 80: ...ions that have already been enqueued The options are Disable and Enable Intel VT for Directed I O VT d Intel VT for Directed I O VT d Select Enable to use Intel Virtualization Technology for Direct I...
Страница 81: ...ck0 Intel VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack The options are Disable and Enable If the item above is set to Enable the f...
Страница 82: ...upport for PCIe root ports 3A 3D The options are Disable and Enable PCI E Completion Timeout Disable Use this feature to enable PCI E Completion Timeout support for electric tuning The options are Yes...
Страница 83: ...and Enable Configure SATA as Select AHCI to configure a SATA drive specified by the user as an AHCI drive Select RAID to configure a SATA drive specified by the user as a RAID drive The options are A...
Страница 84: ...d Enable Port 0 4 5 6 7 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to initialize the device The options are Disable and Enable Port 0 4 5 6 7 SATA Device Type Use this...
Страница 85: ...sSATA RAID Option ROM UEFI Driver Select UEFI to load the EFI driver for system boot Select Legacy to load a legacy driver for system boot The options are Disable EFI and Legacy sSATA Port 0 Port 2 Th...
Страница 86: ...ptions are 1G 4G 16G 64G 256G and 1024B PCI PERR SERR Support Select Enabled to allow a PCI device to generate a PERR SERR number for a PCI Bus Signal Error Event The options are Disabled and Enabled...
Страница 87: ...N Device Select Enabled to enable the Onboard LAN device The options are Enabled and Disabled Onboard LAN1 Option ROM Use this feature to select which firmware function to be loaded for LAN Port1 used...
Страница 88: ...O Chip AST2500 Serial Port 1 Configuration This submenu allows the user to configure the settings of Serial Port 1 Serial Port 1 Select Enabled to enable the selected onboard serial port The options a...
Страница 89: ...speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lin...
Страница 90: ...of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature selects the settings for Function Keys and KeyPad used for Putty which...
Страница 91: ...The options are VT100 VT100 VT UTF8 and ANSI Bits Per Second This item sets the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host compu...
Страница 92: ...enhance data integrity and network security Please reboot the system for a change on this setting to take effect The options are Disable and Enable TPM State Select Enabled to use TPM Trusted Platform...
Страница 93: ...Enabled iSCSI Configuration iSCSI Initiator Name This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format Once the name of the iSCSI Initiator is entered into the sy...
Страница 94: ...ed Erasing Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Select Yes Ever...
Страница 95: ...incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines the number of minutes that must pass between duplicate log events before MECI is incremente...
Страница 96: ...e IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing S...
Страница 97: ...g The default setting is Failover IPMI Network Link Status This item displays the IPMI Network Link status The default setting is Shared LAN Configuration Address Source This feature allows the user t...
Страница 98: ...tus The default setting is Disabled IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled Configuration Address Source This feature allows the user to select the so...
Страница 99: ...d at Setup Select Always for the system to check for a password at bootup or upon entering the BIOS Setup utility The options are Setup and Always Secure Boot This section displays the contents of the...
Страница 100: ...ault secure keys set by the manufacturer The options are Yes and No Enroll EFI Image This feature allows the image to run in Secure Boot Mode Enroll SHA256 Hash Certicate of the image into the Authori...
Страница 101: ...m a file The options are Yes and No Forbidden Signatures Set New Select Yes to load the DBX from the manufacturer s defaults Select No to load the DBX from a file The options are Yes and No Append Sel...
Страница 102: ...48 bin d EFI SERT SHA256 bin 2 EFI Time Based Authenticated Variable When prompted select Yes to load Factory Defaults or No to load from a file Set New Select Yes to load the DBR from the manufacture...
Страница 103: ...order has failed The options are Disabled and Enabled Fixed Boot Order Priorities This option prioritizes the order of bootable devices that the system boots from Press Enter on each entry from top t...
Страница 104: ...15 Dual Boot Option 16 Dual Boot Option 17 Delete Boot Option This feature allows the user to select a boot device to delete from the boot priority list Delete Boot Option Use this item to remove an E...
Страница 105: ...ot option Path for Boot Option Use this item to enter the path for the new boot option in the format fsx path filename efi Boot Option File Path Use this item to specify the file path for the new boot...
Страница 106: ...nd press Enter Save Changes and Reset After completing the system configuration changes select this option to save the changes you have made This will not reset reboot the system Save Changes When you...
Страница 107: ...User Defaults from the Save Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults...
Страница 108: ...nue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps Th...
Страница 109: ...m support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnostic...
Страница 110: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...
Страница 111: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...
Страница 112: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...
Страница 113: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 114: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...
Страница 115: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 116: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...
Страница 117: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 118: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...
Страница 119: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 120: ...anbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All con...
Страница 121: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 122: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...
Страница 123: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 124: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...
Страница 125: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 126: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...
Страница 127: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 128: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto uti...
Страница 129: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 130: ...hot swap 2 5 hard drives PCI Expansion Slots Three PCI E 3 0 x16 slots CPU Slot 3 SXB1A SXB1B slot SXB2A SXB2B slot Two M 2 for PCI E 3 0 x4 or SATA 3 0 slot supports M Key 2280 x16 slot Motherboard...
Страница 131: ...N 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlorate Warning California Best Management Practices Re...
Страница 132: ...ain BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupted When the sy...
Страница 133: ...ry using a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image file into the disc Root directory of a USB device or a writable CD DVD Note If...
Страница 134: ...you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 5 When the screen as shown above displays use the arrow keys to select the item Proceed wit...
Страница 135: ...r the BIOS setup utility From the top of the tool bar click on Boot and press Enter to enter the submenu From the submenu list select Boot Option 1 as shown below Then boot Option 1 to UEFI AP UEFI Bu...
Страница 136: ...errupt this process until the BIOS flashing is complete 10 The screen above indicates that the BIOS update process is completed When you see the screen above unplug the AC power cable from the power s...