Chapter 7: BIOS

7-5

PS/2 Mouse Support

Select Enabled to enable PS/2 Mouse support. Select

 Auto

 to enable the onboard 

PS/2 mouse when a PS/2  mouse is detected. The options are Enable, Disabled, 

and 

Auto

.

Wait For 'F1' If Error

This forces the system to wait until the 'F1' key is pressed when an error occurs. 

The options are Disabled and 

Enabled

.

Hit 'Del' Message Display

Select Enabled to display "Press DEL to run Setup" during POST. The options 

are 

Enabled

 and Disabled. 

Interrupt 19 Capture

Interrupt 19 is the software interrupt that handles boot disk functions. When this item 

is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 

at bootup and allow the drives that are attached to these host adaptors to function 

as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adap-

tors will not capture Interrupt 19, and the drives attached to these adaptors will not 

function as bootable devices. The options are 

Enabled 

and Disabled. 

Watch Dog Function

If enabled, the Watch Dog Timer will allow the system to reboot when it is inactive 

for more than 5 minutes. The options are Enabled and 

Disabled. 

Processor and Clock Options

This submenu displays the status of the processor used in the motherboard and 

allows the user to confi gure the Processor and Clock settings.

Spread Spectrum Mode

Select Enable to enable Clock Spectrum modulation support, which will allow BIOS 

to monitor and attempt to reduce the level of Electromagnetic Interference caused 

by the components whenever needed. The options are 

Disabled

 and Enabled.

Ratio CMOS Setting (Available when CPU Ratio is set to manual)

This option allows the user to set the ratio between the CPU Core Clock and the FSB 

Frequency. (

Note

: if an invalid ratio is entered, the AMI BIOS will restore the setting 

to the previous state.) The default setting depends on the type of CPU installed on 

the motherboard. The default setting for this motherboard is [

20

].

Содержание SUPERO SUPERSERVER 2027GR-TRF

Страница 1: ...SUPER SUPERSERVER 2027GR TRF USER S MANUAL Revision 1 0...

Страница 2: ...ny such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits f...

Страница 3: ...ystem and describes the main features of the Super X9DRG HF serverboard and the SC218G R1800B chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the system int...

Страница 4: ...verboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC218G R1800B 2U rackmount server chassis You should follow the procedures given in this chapter when insta...

Страница 5: ...v Preface Notes...

Страница 6: ...acking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3 Reduced A...

Страница 7: ...pter 5 Advanced Serverboard Setup 5 1 Handling the Serverboard 5 1 Precautions 5 1 Unpacking 5 2 5 2 Serverboard Installation 5 2 5 3 Connecting Cables 5 3 Connecting Data Cables 5 3 Connecting Power...

Страница 8: ...pansion Card Setup 6 8 Low Profile Expansion Card Setup 6 10 Installing Graphics GPU Cards 6 11 6 6 Power Supply 6 13 Power Supply Replacement 6 13 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Se...

Страница 9: ...S One passive 2U CPU heatsink SNK P0048PS Riser Cards One RSC R2UG 2E16 X9 for two PCI E x16 cards left front side One RSC R2UG 2E16R X9 for two PCI E x16 cards right front side One RSC R2UG E8G X9 fo...

Страница 10: ...ATA A SATA controller is integrated into the chipset to provide a 10 port SATA subsystem which is RAID 0 1 5 and 10 supported Two of these are SATA 3 0 ports and eight are SATA 2 0 ports The SATA dri...

Страница 11: ...supply without shutting down the system See Chapter 6 for details SATA Subsystem The SC218G R1800B chassis includes ten 2 5 drive bays which may be used to house hot swap SATA drives RAID 0 1 5 and 10...

Страница 12: ...rocess complex image calculations and then route the data out through the VGA port on the serverboard The 2027GR TRF can support four standard size double width GPUs The NVIDIA M2075 and M2090 GPUs wh...

Страница 13: ...600 DDRIII DDRIII P1 P1 P0 P0 0 4 0 3 0 2 0 1 1 4 1 3 1 2 1 1 QPI 8G LANE6 SLOT 1 SLOT 5 SLOT 6 E5 2600 Series PCH C602 C604 PCI E X16 G3 DMI2 LANE5 LANE1 2 3 4 SPI SIO W83527 DMI2 BMC WPCM450 PCI E X...

Страница 14: ...Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support super...

Страница 15: ...r It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded...

Страница 16: ...able before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Rack mounted equipment should...

Страница 17: ...hat the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanica...

Страница 18: ...ou are using Note This rail will fit a rack between 26 5 and 36 4 deep Identifying the Sections of the Rack Rails The chassis package includes two rail assemblies in the rack mounting kit Each assembl...

Страница 19: ...fully extended from the rack This prevents the server from coming completely out of the rack when when the chassis is pulled out for servicing Releasing the Inner Rail Releasing Inner Rail from the Ou...

Страница 20: ...e inner rail firmly against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until...

Страница 21: ...of the rack If necessary use screws to secure the outer rails to the rack as illustrated above 4 Pull out the rear of the outer rail adjusting the length until it fits within the posts of the rack 5...

Страница 22: ...s at the front locking position of the middle rail 4 Align the chassis inner rails with the front of the middle rails 5 Slide the inner rails on the chassis into the middle rails keeping the pressure...

Страница 23: ...e chassis onto a rack Installing the Chassis into a Rack 1 Install the whole rail assembly onto the rack as described previously 2 Release the inner rail without retracting the middle rail 3 Install t...

Страница 24: ...2 10 SUPERSERVER 2027GR TRF User s Manual Notes...

Страница 25: ...LEDs and buttons for the system These LEDs provide constant information on the system and on the overall health of system components There are additional LEDs on each of the drive carriers This chapt...

Страница 26: ...rol panel a reset button and a power on off button Power The main power button is used to apply or remove power from the power supply to the server system Turning off system power with this button rem...

Страница 27: ...system or the ambient room temperature being too warm Check the routing of the cables and make sure that all fans are present and operating normally Also check to make sure that the air shrouds are i...

Страница 28: ...ach drive carrier has a green LED When illuminated this green LED on the front of the drive carrier indicates drive activity A connection to the backplane enables this LED to blink on and off when tha...

Страница 29: ...e operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits another person who is familiar with the power off c...

Страница 30: ...uct may be connected to an IT power system In all cases make sure that the unit is also reliably connected to Earth ground Serverboard Battery CAUTION There is a danger of explosion if the onboard bat...

Страница 31: ...PCBs come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only do not touch its components peripheral chips memory modules o...

Страница 32: ...ice is not strictly followed Figure 4 1 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do not damage the battery in any way a damaged battery may...

Страница 33: ...to handle them very carefully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally...

Страница 34: ...he cover off 2 Make sure that the I O ports on the serverboard align properly with their respective holes in the I O shield at the back of the chassis 3 Carefully mount the serverboard to the serverbo...

Страница 35: ...drive data cables I SATA0 3 I SATA4 5 SATA sideband cables T SGPIO 1 for drives 0 3 T SGPIO S for drives 4 7 T SGPIO 2 for drives 8 9 Control Panel cable JF1 GPU power cables JPW3 JPW4 JPW6 JPW7 SATA...

Страница 36: ...ance with the PC 99 specification See Figure 5 2 below for the colors and locations of the various I O ports Figure 5 1 Control Panel Header Pins Figure 5 2 I O Ports NMI x Key 3 3V FP UID 3 3V Stby N...

Страница 37: ...e to install the serverboard into the chassis before you install the CPU heatsinks When receiving a serverboard without a processor pre installed make sure that the plastic CPU socket cap is in place...

Страница 38: ...ARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are aligned caref...

Страница 39: ...make sure that they are flush with the socket 8 Close the load plate Lock the lever labeled Close 1st then lock the lever labeled Open 1st Use your thumb to gently push the load levers down until the...

Страница 40: ...damage the CPU 5 Add the two remaining screws then finish the installation by fully tightening all four screws Installing a CPU Heatsink Removing the Heatsink 1 Unscrew and remove the heatsink screws...

Страница 41: ...ally into its slot Pay attention to the notch along the bottom of the module to avoid installing incorrectly see Figure 5 4 3 Gently press down on the DIMM module until it snaps into place in the slot...

Страница 42: ...airs 1 CPU 2 DIMMs CPU1 P1 A1 P1 B1 1 CPU 4 DIMMs CPU1 P1 A1 P1 B1 P1 C1 P1 D1 2 CPUs 4 DIMMs CPU1 CPU2 P1 A1 P1 B1 P2 E1 P2 F1 2 CPUs 6 DIMMs CPU1 CPU2 P1 A1 P1 B1 P1 C1 P1 D1 P2 E1 P2 F1 2 CPUs 8 DI...

Страница 43: ...upports PCI expan sion cards in the following slots on the serverboard One PCI Express 3 0 x8 low profile card in x16 slot One PCI Express 2 0 x4 standard card in x16 slot These slots require the use...

Страница 44: ...A1 S SATA2 S SATA3 DM1 LE1 DM2 JPL1 JWD1 J30 JPB1 J29 JPBR1 JPME1 JWP1 JPG1 FAN2 FAN1 FANF FAND FANH FANC FANG FANE FAN4 FAN3 FANA FANB T SGPIO5 T SGPIO1T SGPIO2 I SATA3 I SATA4 I SATA5 JF1 JTPM1 JPW2...

Страница 45: ...tor Description Battery Onboard Battery FAN1 FAN4 CPU Fans FANA FANH GPU Fans JCOM1 COM Header for Front Chassis Access JF1 Control Panel Header JL1 Chassis Intrusion Header JOH1 Overheat LED Indicato...

Страница 46: ...PU2 is populated SW1 UID Switch T SGPIO 1 2 S Serial Link General Purpose I O Headers USB 0 1 Back Panel USB Ports LED Description State Status DM1 BMC Heartbeat LED Green BMC Normal LE1 Standby PWR L...

Страница 47: ...finition 1 Power Button 2 Ground Power Connectors Three SMC proprietary power connectors are located at JPW1 JPW2 and JPW9 to provide main power to the serverboard Seven 12V 8 pin power connectors lo...

Страница 48: ...e The blue LED pin 7 works as the UID LED indicator for the front panel UID button located on pins 13 14 of JF1 When Jumper J_UID_OW is set to off default the red LED takes precedence over the blue LE...

Страница 49: ...system See the table on the right for pin definitions Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Control HDD UID LED Pin Definitions JF1 Pin Definition 13 UID Signal 3 3V 14 HDD Activity...

Страница 50: ...t Output headers are provided on the serverboard These headers sup port serial link interfaces for the onboard SATA ports See the table on the right for pin definitions T SGPIO Pin Definitions Pin Def...

Страница 51: ...us USB Two Universal Serial Bus ports USB0 1 are located on the I O backplane Connect USB devices to these ports Ethernet Ports Two Ethernet ports are located next to the USB 0 1 on the IO backplane I...

Страница 52: ...d on our Website UID Switch Pin Definition 1 Button In 2 Ground 3 Ground 4 Ground UID LED LE4 Status Color State OS Status Blue On Windows OS Unit Identified Blue Blinking Linux OS Unit Identified Ove...

Страница 53: ...2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS...

Страница 54: ...ettings Watch Dog must also be enabled in BIOS Note When enabled the user needs to write their own application software in order to disable the Watch Dog Timer Watch Dog Jumper Settings Jumper Setting...

Страница 55: ...ents See the table on the right for more details Onboard PWR LED Indicator LED Color Definition Off System Off power cable not connected Green System On Green Flashing Quickly ACPI S1 State BMC Enable...

Страница 56: ...more information BMC Heatbeat LED Indicator LED Status Green Blinking BMC Normal Rear UID LED The rear UID LED is located at LE4 on the backplane This LED is used in conjunc tion with the rear UID sw...

Страница 57: ...aged with your system Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of these...

Страница 58: ...cial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Note The default User Name and Password for SuperDo...

Страница 59: ...ded from our Web Site at ftp ftp supermicro com utility Supero_Doctor_III You can also download the SDIII User s Guide at http www supermicro com manuals other SDIII_User_Guide pdf For Linux we will r...

Страница 60: ...5 28 SUPERSERVER 2027GR TRF User s Manual Notes...

Страница 61: ...damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a gro...

Страница 62: ...is very important that the chas sis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components System Fan Fai...

Страница 63: ...ower down the system and disconnect the chassis power cord 2 Remove the screws securing the fan housing to the floor of the chassis See the illustrations below to determine the location of the screws...

Страница 64: ...fan as follows Front and GPU Fans Clip the front and rear fan guards A into the left and right side clips B Figure 6 4 Reassembling the Mid Fan Housing Figure 6 3 Reassembling a Front or GPU Fan Hous...

Страница 65: ...s behind the two system fans aligning the mounting holes of the air shroud with those of the chassis 2 Secure the lower portion of the air shroud to the chassis using two screws 3 Place the upper port...

Страница 66: ...rive carrier out of the chassis Figure 6 6 Removing a Hard Drive Carrier Warning Except for short periods of time swapping hard drives do not operate the server with the hard drive carriers removed En...

Страница 67: ...nting holes of the drive Note that there are holes in the carrier which are marked SATA to aid in correct installation 3 Secure the drive to the carrier with four screws Use the M3 flat head screws in...

Страница 68: ...from any power source 2 Confirm that you have the correct expansion card riser card and expansion card bracket for the SC218G chassis 3 Remove the PCI E slot covers at the rear of the chassis 4 Inser...

Страница 69: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 10 Installing Expansion Cards into the Expansion Card Bracket Figure 6 11 Installing the Expansion Card Bracket into the Chassis 1 6...

Страница 70: ...nect the chassis from any power source 2 Select which one of the two low profile PCI E slots you need to use depend ing on whether using a standard or UIO riser card 3 Remove the screws securing the P...

Страница 71: ...mounting holes in the brackets 3 Secure each card to the bracket using the six screws which are included for this purpose Figure 6 13 Installing GPU Cards into the Left and Right GPU Brackets Left Sid...

Страница 72: ...12 SUPERSERVER 2027GR TRF User s Manual Figure 6 14 Installing the Left and Right GPU Brackets into the Chassis Left Side GPU Bracket and Cards Right Side GPU Bracket and Cards Side Screws Side Screw...

Страница 73: ...placement The SC218G includes dual redundant power supplies In the event of a power supply failure the remaining power supply will automatically take over The failed power module can be easily replace...

Страница 74: ...6 14 SUPERSERVER 2027GR TRF User s Manual Notes...

Страница 75: ...ht frame displays the key legend Above the key legend is an area reserved for text messages When an option is selected in the left frame it is highlighted in white Often a text message will accompany...

Страница 76: ...Do not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect specia...

Страница 77: ...as 17 30 00 Supermicro X8QB6 E BIOS Version This item displays the BIOS vision used in your system BIOS Build Date This item displays the date when this BIOS was built Processor The AMI BIOS will aut...

Страница 78: ...ng POST to reduce the time needed for system boot The options are Enabled and Disabled Quiet Boot Use this feature to select the bootup screen display between POST messages or the OEM logo Select Disa...

Страница 79: ...ttached to these adaptors will not function as bootable devices The options are Enabled and Disabled Watch Dog Function If enabled the Watch Dog Timer will allow the system to reboot when it is inacti...

Страница 80: ...rn Ordering and Legacy Ordering Max CPUID Value Limit This feature allows the user to set the maximum CPU ID value Enable this feature to boot the legacy operating systems that cannot support processo...

Страница 81: ...when Intel EIST Technology is enabled Select Enabled to use the TurboMode Technique to boost system performance The options are Enabled and Disabled Performance Walt Select Use this feature to balance...

Страница 82: ...and 0xC000 0000 MMIOH Size Per IOH Use this feature to select the memory_mapped IOH size to be allocated to each IOH The options are 2G 4G 6G and 8G Logical Interrupt Mode This item is used to select...

Страница 83: ...installed in different DIMM slots Select Intra Socket Block Interleaving to enable memory interleaving between blocks of memory installed in the same DIMM slot Select Automatic to allow BIOS to autom...

Страница 84: ...ency Limit This feature forces a DDR3 memory module to run at a frequency other than what the system has detected The available options are Auto 800 MHz 978 MHz 1067 MHz and Auto Initialization Mode U...

Страница 85: ...th Bridge settings Relaxed Ordering Select Enabled to enable PCI Express Relaxed_Ordering support which will allow certain transactions to be executed first by passing other transactions that were iss...

Страница 86: ...Sensor Select Enabled to activate the thermal sensor The options are Disabled and Enabled South Bridge Configuration This feature allows the user to configure Intel ICH South Bridge settings USB Func...

Страница 87: ...n Power Off and Last State SATA Master Break Event If this feature is set to Enabled activities on the SATA master drive will break from the C3 C6 state The settings are Enabled and Disabled PCIE Port...

Страница 88: ...cted Use this feature to select the AHCI Codebase for the ICH South Bridge The options are BIOS Native Module and Intel AHCI ROM SATA 2 Configuration Available when the option IDE is selected Select E...

Страница 89: ...e PIO mode 0 It has a data transfer rate of 3 3 MB s Select 1 to allow AMI BIOS to use PIO mode 1 It has a data transfer rate of 5 2 MB s Select 2 to allow AMI BIOS to use PIO mode 2 It has a data tra...

Страница 90: ...elect UDMA5 to allow BIOS to use Ultra DMA mode 5 It has a data transfer rate of 100 MB s Select UDMA6 to allow BIOS to use Ultra DMA mode 6 It has a data transfer rate of 133 MB s The options are Aut...

Страница 91: ...options are Disabled and Enabled SR IOV Supported Single Root I O Virtualization is an industry standard mechanism that allows devices to be shared simultaneously among several virtual machines SR IO...

Страница 92: ...e user to configure USB settings for the motherboard Legacy USB Support Select Enabled to use Legacy USB devices If this item is set to Auto Legacy USB support will be automatically enabled if a legac...

Страница 93: ...ACPI v2 0 and ACPI v3 0 Please refer to ACPI s Website for further explanation http www acpi info ACPI APIC Support Select Enabled to include the ACPI APIC Table Pointer in the RSDT Root System Descr...

Страница 94: ...g smooth playback and reducing the dependency on other timestamp calculation devices such as an x86 RDTSC Instruction embed ded in the CPU The High Performance Event Timer is used to replace the 8254...

Страница 95: ...including the LED and the buzzer to be triggered when the CPU temperature reaches about 5oC above the threshold temperature as predefined by the CPU manufacturer to give the CPU and system fans addit...

Страница 96: ...below the CPU Temperature Tolerance The motherboard fans and CPU will run normally as configured in the BIOS The fans may adjust to a faster speed depending on the Fan Speed Control settings User inte...

Страница 97: ...quietness The Options are Full Speed FS Performance PF Balanced BL and Energy Saving ES Voltage Monitoring CPU1 Vcore CPU2 Vcore CPU3 Vcore CPU4 Vcore 1 0V 1 2V 1 8V 1 1V 12V 1 5V 3 3V V 3 3VSB Batter...

Страница 98: ...feature allows the user to configure the IPMI LAN adapter with a network ad dress as shown in the following graphics Channel Number This feature displays the channel number Channel Number Status This...

Страница 99: ...value of each three digit number separated by dots should not exceed 255 Current IP Address in BMC The BIOS will automatically enter the current IP address in BMC for this machine however it may be ov...

Страница 100: ...this machine however it may be overwritten The value of each three digit number separated by dots should not exceed 255 Remote Access Configuration Remote Access This allows the user to enable the Re...

Страница 101: ...on The options are No Delay Delay 1 Sec Delay 2 Sec and Delay 4 Sec Trusted Computing Optional TCG TPM Support Select Yes on this item and enable the TPM jumper on the motherboard to enable TCG TPM 1...

Страница 102: ...ge to keep the current TPM commands without making any changes Select Dis abled to abandon the changes you have made on TPM commands The options are Enabled Disabled and Don t Change TPM Enable Disabl...

Страница 103: ...t Device SATA XXXXXXXXX Hard Disk Drive CD DVD ROM Drive Removable Drive This feature allows the user to specify the boot sequence from all available hard disk drives The settings are Disabled and a l...

Страница 104: ...d press Enter to access the submenu and then enter a new Supervisor Password User Access Level Available when Supervisor Password is set as above Select Full Access to grant full User read and write a...

Страница 105: ...etup Utility screen to enter the Exit BIOS Setup screen Save Changes and Exit When you have completed the system configuration changes select this option to leave the BIOS Setup Utility and reboot the...

Страница 106: ...to automatically load Optimal De faults to the BIOS Settings The Optimal settings are designed for maximum system performance but may not work best for all computer applications Load Fail Safe Default...

Страница 107: ...ors will not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs BIOS Error Beep Codes Beep Code Error Mess...

Страница 108: ...A 2 SUPERSERVER 2026GT TRF User s Manual Notes...

Страница 109: ...in Chapter 5 for details GPUs Graphics Processing Units A total of four GPUs are supported true PCI E 3 0 x16 signal SATA Controller Intel on chip controller for 10 SATA ports RAID 0 1 5 and 10 Drive...

Страница 110: ...perating Relative Humidity 8 to 90 non condensing Non Operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 C...

Страница 111: ...orm be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such pro...

Страница 112: ...B 4 SUPERSERVER 2027GR TRF User s Manual Notes...

Отзывы: