5-6
1000BASE-T Pin Assignments
All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use
straight-through cables for all network connections to PCs, servers, or switches.
The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports
require that all four pairs of wires be connected. Note that for 1000BASE-T operation, all
four pairs of wires are used for both transmit and receive.
1000BASE-T Cable Requirements
All Category 5 UTP cables that are used for 100BASE-TX connections should also work
for 1000BASE-T, providing that all four wire pairs are connected. However, it is
recommended that for all critical connections, or any new cable installations, Category
5e (enhanced Category 5) or Category 6 cable should be used. The Category 5e and 6
specifications include test parameters that are only recommendations for Category 5.
Therefore, the first step in preparing existing Category 5 cabling for running
1000BASE-T is a simple test of the cable installation to be sure that it complies with the
IEEE 802.3-2008 standards.
10GBASE-T Cable Requirements
Use 100-ohm Category 5e, 6, 6a or 7 twisted-pair cable for 10GBASE-T connections as
specified in
. Also be sure that the length of any twisted-pair connection does
not exceed the lengths specified in this table.
The primary cable specified for 10GBASE-T is augmented Category 6 (Category 6a).
Other types also work, but the specific installation may have to be qualified for 10G
operation. See the IEEE 802.3an-2006 standard and the relevant TIA specifications
listed therein.
Installed Category 6 cabling must pass tests specified in the ANSI/TIA-TSB-155 and
ISO/IEC 24750 standards. Category 6a cables must also pass test parameters specified
in the ANSI/TIA/EIA-568-B.2-10 standard. Methods of mitigating of alien crosstalk in
Category 6 and 6a cable is covered in ANSI/TIATSB-155 and ISO/IEC TR24750.
Table 5-4. 1000BASE-T MDI and MDI-X Port Pinouts
Pin
MDI Signal Name
MDI-X Signal Name
1
Bi-directional Pair A Plus (BI_DA+)
Bi-directional Pair B Plus (BI_DB+)
2
Bi-directional Pair A Minus (BI_DA-)
Bi-directional Pair B Minus (BI_DB-)
3
Bi-directional Pair B Plus (BI_DB+)
Bi-directional Pair A Plus (BI_DA+)
4
Bi-directional Pair C Plus (BI_DC+)
Bi-directional Pair D Plus (BI_DD+)
5
Bi-directional Pair C Minus (BI_DC-)
Bi-directional Pair D Minus (BI_DD-)
6
Bi-directional Pair B Minus (BI_DB-)
Bi-directional Pair A Minus (BI_DA-)
7
Bi-directional Pair D Plus (BI_DD+)
Bi-directional Pair C Plus (BI_DC+)
8
Bi-directional Pair D Minus (BI_DD-)
Bi-directional Pair C Minus (BI_DC-)
Содержание SSE-X3348T
Страница 1: ...SSE X3348T and SSE X3348TR 48 Port 10G Top of Rack Switches Installation Manual Revison 1 0 ...
Страница 6: ...SSE X3348T SSE X3348TR Switch Installation Manual vi Notes ...
Страница 10: ...SSE X3348T SSE X3348TR Switch Installation Manual x Notes ...
Страница 14: ...SSE X3348T SSE X3348TR Switch Installation Manual 1 4 Notes ...
Страница 32: ...SSE X3348T SSE X3348TR Switch Installation Manual 2 18 Notes ...
Страница 39: ...4 3 Chapter 4 Installing the Switch Figure 4 1 Switch Cooling B2F Airflow SSE X3348TR F2B Airflow SSE X3348T ...
Страница 42: ...SSE X3348T SSE X3348TR Switch Installation Manual 4 6 Figure 4 2 Connecting AC Power 1 2 ...
Страница 50: ...SSE X3348T SSE X3348TR Switch Installation Manual 4 14 Notes ...
Страница 61: ...5 11 Chapter 5 Making Network Connections ...
Страница 65: ...SSE X3348T SSE X3348TR Switch Installation Manual 6 4 Notes ...
Страница 72: ...SSE X3348T SSE X3348TR Switch Installation Manual 8 3 ...
Страница 74: ...SSE X3348T SSE X3348TR Switch Installation Manual ...