Summary of Contents for NX3CE12

Page 1: ...WatchGuard XTM 1050 Hardware Guide XTM 1050 XTM 1050 with Fiber Card XTM 1050 with 10 Gb Interface Module NX3CE12 ...

Page 2: ... 613 6600 or visit www watchguard com Copyright and Patent Information Copyright 1998 2011 WatchGuard Technologies Inc All rights reserved WatchGuard the WatchGuard logo LiveSecurity and any other mark listed as a trademark in the Terms of Use portion of the WatchGuard Web site that is used herein are either registered trademarks or trademarks of WatchGuard Technologies Inc and or its subsidiaries...

Page 3: ...ty to proactively protect your network Capable of 10 gigabit throughput the XTM 1050 has the reliability redundancy traffic management and port density that demanding high speed networks require The XTM 1050 has redundant replaceable power supply units replaceable cooling fans and offers an available insertable card with fiber optic interfaces Fireware XTM OS The XTM 1050 devices support WatchGuar...

Page 4: ...net cable green 1 cross over Ethernet cable red 1 serial cable with an RJ 45 connector 2 power cords 1 front rack mount kit 1 side rail mount kit with installation instructions 1 bag screws About Your Hardware Hardware Specifications Processor Dual 2 33 GHz Quad Core Intel Xeon Memory Flash 1 GB Memory RAM 4 GB Power supply 100 240 VAC Autosensing Dimensions D 20 1 51 0 cm W 16 9 43 0 cm H 3 5 8 8...

Page 5: ... ports 4x on removable module Interfaces 12 and 13 are labeled Management Ethernet Fiber Option replaces4ofthe14 RJ 45 ports 4 GbE SFP Module replaces standard 4x Copper module Includes 4x 1000BaseSX Optical Transceivers 850 nm Vertical Cavity Surface Emitting Laser VCSEL LC Duplex Fiber Connector 10 Gb Interface Module replaces4ofthe14 RJ 45 ports 10 Gb Interface Module replaces standard 4x Coppe...

Page 6: ...e in safe mode press and hold the down arrow button when you power on the device For detailed information about the LCD indicator panel and the LCD console buttons see Use the LCD Interface on page 10 Power When the device is powered on the power indicator is green Arm Disarm When the device is armed this indicator is green When the device is disarmed this indicator is red Hard disk bay Reserved f...

Page 7: ...aces labeled Management At the top of each RJ45 interface labeled Management interface ports 12 and 13 there is a pair of indicators The indicator at the left of the interface is the activity indicator for that interface The indicator at the right shows the connection speed for that interface Indicator Indicator color Interface Status Activity lower left Green Power on connection established Not l...

Page 8: ...ed 8 and 9 There are activity and connection speed indicators for each 10 Gb interface port but the location indicators is different from the location of the indicators for ports 0 7 See the diagram below for the location of the activity and connection speed indicators for each port on the 10 Gb Interface Module For each interface port on the 10 Gb Interface Module o The Activity LED blinks when d...

Page 9: ...ly Replaceable power supply and power switch There are two power supplies on the XTM 1050 each with their own power indicator light The power switch activates both power supplies It is not necessary to turn off the XTM 1050 to replace a failed power supply If one of the power supplies fails the green power indicator light for that power supply goes out and an audible alarm will sound Caution You m...

Page 10: ... between 32 104 F or 0 40 C Reduced Air Flow When you install the XTM 1050 in a rack make sure that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading When you mount the XTM 1050 in the rack avoid hazardous conditions caused by uneven mechanical loading Circuit Overloading Make sure you connect the XTM 1050 to the power supply circuit in such ...

Page 11: ...of any kind into slots or openings on this equipment If you make contact with a voltage point or short out a part it can result in fire or electrical shock o If the equipment is supplied with a three conductor AC power cable the power cable must be plugged in to an approved three contact electrical outlet with the grounding wire connected to an electrical ground safety ground at the power outlet o...

Page 12: ...e saved You can then use the saved files if you reconfigure a device with one of the setup wizards To put an XTM 1050 into safe mode press and hold the down arrow button on the device front panel when you power on the device Hold down the button until Safe Mode Starting appears on the LCD screen When the device is in safe mode the model number followed by the word Safe appears on the LCD screen an...

Page 13: ... fan status Case cooling fan speeds for the four device fans Voltage CPU core voltage the battery voltage and the 3 3V power supply voltage Configuration Information IP addresses and subnet masks assigned to each interface on the device Default gateway Appliance Software Information OS type Fireware XTM build number Uptime Time interval since the device was last restarted Time interval since a con...

Page 14: ... the Right Arrow button to scroll through options until Hardware Monitor appears 2 Press the Down Arrow button to see the options below that menu item 3 Press the Right Arrow button to scroll through the items in the Hardware Monitor menu until CPU temperature appears 4 Press the Up Arrow button to return to the main category level ...

Page 15: ...for performance of enforcement of or damages or other relief on account of any such warranties or any breach thereof 2 REMEDIES If any Product does not comply with the WatchGuard warranties set forth in Section 1 above WatchGuard will following receipt of the product you claim is defective and at its option either a repair the Product or b replace the Product provided that you will be responsible ...

Page 16: ...or the International Sales of Goods as amended shall not apply You agree not to directly or indirectly transfer the Product or associated documentation to any country to which such transfer would be prohibited by the U S Export laws and regulations If any provision of this Warranty is found to be invalid or unenforceable then the remainder shall have full force and effect and the invalid provision...

Page 17: ...Hardware Guide 15 Legal and Regulatory Information Declaration of Conformity ...

Page 18: ...ctive LVD of the European Union EU Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel broulleur du Canada VCCI Notice Class A ITE CAUTION DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQ...

Page 19: ...S Statement The member states of the European Union approved directive 2002 95 EC Restrictions of Hazardous Substances RoHS directive that becomes valid on July 1 2006 It states that all new electrical and electronic equipment put on the market within the member states must not contain certain hazardous materials The XTM 1050 will comply with the European Union s R0HS directive 2002 95 EC and simi...

Page 20: ...ls policy REACH Registration Evaluation Authorization and restriction of Chemicals came into effect on June 1st 2007 REACH is Europe s new chemicals legislation which is applicable in all 27 EU Member States as well as the EFTA European Economic Area EEA REACH creates a new system for gathering information assessing risks to human health and the environment and authorizing or restricting the marke...

Page 21: ... product documentation on our public web site at www watchguard com help documentation We include below the full text of the GNU General Public License To get the source code covered by this license contact WatchGuard Technical Support at United States or Canada 877 232 3531 All other countries 1 360 482 1083 You can download the source code at no charge If you request the material be sent to you ...

Page 22: ... if you wish that you receive source code or can get it if you want it that you can change the software or use pieces of it in new free programs and that you know you can do these things To protect your rights we need to make restrictions that forbid anyone to deny you these rights or to ask you to surrender the rights These restrictions translate to certain responsibilities for you if you distrib...

Page 23: ...t you changed the files and the date of any change You must cause any work that you distribute or publish that in whole or in part contains or is derived from the Program or any part thereof to be licensed as a whole at no charge to all third parties under the terms of this License Ifthe modified program normally reads commands interactively when run you must cause it when started running for such...

Page 24: ...ution of the source code even though third parties are not compelled to copy the source along with the object code 4 You may not copy modify sublicense or distribute the Programexcept as expressly provided under this License Any attempt otherwise to copy modify sublicense or distribute the Program is void and will automatically terminate your rightsunderthisLicense However partieswhohavereceived c...

Page 25: ...etail to address new problems or concerns Each version is given a distinguishing version number If the Program specifies a version number of this License which applies to it and any later version you have the option of following the terms and conditions either of that version or of any later version published by the Free Software Foundation If the Program does not specify a version number of this ...

Page 26: ...24 WatchGuard XTM 1050 Legal and Regulatory Information ...