SC847E1C/2C JBOD Chassis Manual
5-6
Figure 5-4: Inner Rails Installed on the Chassis
Figure 5-3: Installing the Inner Rails
Installing The Inner Rails on the Chassis
Installing the Inner Rails
1.
Confirm that the left and right inner rails have been correctly identified.
2.
Place the inner rail firmly against the side of the chassis, aligning the hooks
on the side of the chassis with the holes in the inner rail.
3. Slide the inner rail forward toward the front of the chassis until the rail clicks
into the locked position, which secures the inner rail to the chassis.
4. Secure the inner rail to the chassis with the screws provided.
5. Repeat steps 1 through 4 above for the other inner rail.
3
1
4
1
4
2
Inner Rails
Warning: do not pick up the server by the front handles. They are designed
to pull the system from a rack only.