Страница 1: ...USER S MANUAL Revision 1 0 A Server AS 1014S WTRT...
Страница 2: ...industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful in...
Страница 3: ...utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp driver AMD SP3 Product sa...
Страница 4: ...ons 16 Server Precautions 17 Rack Mounting Considerations 17 Ambient Operating Temperature 17 Airflow 17 Mechanical Loading 17 Circuit Overloading 18 Reliable Ground 18 2 3 Installing the Rails 18 Ide...
Страница 5: ...Drive 41 Air Shroud 43 Checking the Airflow 43 DVD ROM Drive Installation 44 System Cooling 44 Changing a System Fan 44 Power Supply 46 Power Supply Failure 46 Installing Expansion Cards 47 Chapter 4...
Страница 6: ...6 3 Advanced 72 6 4 IPMI 90 6 5 Event Logs 93 6 6 Security 95 6 7 Boot 98 6 8 Save Exit 100 6 9 BIOS Update Using IPMI 102 Appendix A BIOS POST Codes Appendix B Standardized Warning Statements for AC...
Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermic...
Страница 8: ...vered it Decide on a suitable location for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and e...
Страница 9: ...TB of ECC DDR4 3200 RDIMM LRDIMM 3DS NVDIMM memory in 8 DIMM slots Chipset SoC chipset Expansion Slots Two PCI E 4 0 x16 slots FHFL with riser card RSC W 66G4 One PCI E 4 0 x16 slot low profile with...
Страница 10: ...ton The reset button is used to reboot the system 8 Power Button The main power button is used to apply or remove power from the power supply to the server Turning off system power with this button re...
Страница 11: ...Front Chassis Features Item Feature Description 1 Hard Drive Carrier Carrier for hot swap hard drive 2 Slim FDD Bay USB COM Port Tray Slim Fixed Disk Drive USB COM port tray Optional 3 Slim DVD ROM Dr...
Страница 12: ...s 1 1 4 4 3 2 Rear Chassis Features Item Feature Description 1 Power Supply Redundant power supply modules 2 I O Backpanel Rear I O ports see Section 4 3 3 Expansion Card Slot Slot for low profile exp...
Страница 13: ...MH4 MH17 JSXB1A JSXB1C MH8 MH6 MH9 SXB1C SXB1B PCI E 4 0 X16 X16 SXB1A SXB2 PCI E 4 0 X16 1 2 RST 2 3 NMI JWD1 WATCH DOG CMOS CLEAR 1 2 NORMAL 2 3 BIOS RECOVERY JDB1 OH LED SATA16 SATA17 SATA8 15 SAT...
Страница 14: ...header FAN 1 6 System cooling fan headers JF1 Front control panel JSD1 JSD2 SATA DOM power connector JTPM1 Trusted Platform Module TPM Port 80 connector SATA0 SATA1 Internal SATA Ports JL1 Chassis in...
Страница 15: ...EPYC Rome Processor USB_1_SS_2TX USB_1_HSD2 USB 3 0 front panel P2 15 0 P3 15 0 SXB1 10Gb LAN RJ45 10Gb LAN RJ45 COM1 MLAN LAN1 USB3 0 X 2 ID SW Rear I O VGA USB3 0 X 2 LAN2 ID LED Slim SAS x8 G2 7 4...
Страница 16: ...k Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where...
Страница 17: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...
Страница 18: ...em remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mounting this unit in a part...
Страница 19: ...the rack Assembling the Outer Rails 1 Identify the left and right outer rails by examining the ends which bend outward Match the left front outer rail with the left rear outer rail and the same for th...
Страница 20: ...ck C Push the rail into the rack until the quick release bracket snaps into place securing the rail to the rack Keep the rail horizontal 2 Adjust the rail to reach just past the full depth of your rac...
Страница 21: ...ls on the rack 3 Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting When the server has been pushed completely...
Страница 22: ...t determine how far follow the server will extend out the front of the rack Larger chassis should be positioned to balance the weight between front and back If a bezel is included on your server remov...
Страница 23: ...cords from the power strip or outlet If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnect the power cord s from the power supply modules...
Страница 24: ...Server AS 1014S WTRT User s Manual 24 Figure 3 1 Removing the Chassis Cover 1 4 1 2 1 2 1 3 Note Graphics in this manual are for illustration purposes only Your components may look slightly different...
Страница 25: ...a processor CPU and heatsink to the motherboard Notes Use ESD protection Power down the system as described in Section 3 1 The motherboard should be installed into the chassis first and the processor...
Страница 26: ...me will raise up after the last screw securing it 1 is removed Gently allow it to lift up to its stopping position 3 Lift the rail frame up by gripping the lift tabs near the front end of the rail fra...
Страница 27: ...ame CPU package assembly from its shipping tray and while gripping the handle align the flanges of the carrier frame onto the rails of the rail frame so its pins will be at the bottom when the rail fr...
Страница 28: ...bs marked Remove at the middle of the cap and pull vertically upwards to remove the PnP cover cap Caution The exposed socket contacts are extremely vulnerable and can be damaged easily Do not touch or...
Страница 29: ...of torque using a Torx T20 driver The Force Frame secures both the Rail Frame and CPU Package Caution The screw tightening sequence of 1 2 3 must be executed in the proper sequence to avoid catasrophi...
Страница 30: ...e socket frame 12 Using a diagonal pattern tighten the four screws down on the heatsink evenly till it is secure 1 Screw 2 Screw 3 Screw 4 Screw Figure 3 10 Mounting the Heatsink Figure 3 11 Securing...
Страница 31: ...ail frame rotate it downwards till it rests above and locks over the socket housing in its horizontal position 8 Push and rotate down the force frame till it is over the external cap and rail frame in...
Страница 32: ...TB of ECC DDR4 3200MHz speed RDIMM LRDIMM 3DS NVDIMM memory in eight slots Refer to the table below for additional memory information Populating RDIMM RDIMM 3DS LRDIMM LRDIMM 3DS DDR4 Memory Modules...
Страница 33: ...Ms CPU1 Unbalanced not recommended 8 DIMMs CPU1 J19 H12SSW iN MEGERAC LICENSE MAC CODE IPMI CODE BAR CODE BT1 MH15 JSXB2 JTPM1 1 2 JUSBA1 4 1 5 9 JF1 1 2 JSD2 1 3 JSD1 1 3 JNCSI1 JUSBRJ45 LED6 A C LED...
Страница 34: ...the memory slots there is no specific sequence or order required 2 Push the release tabs outwards on both ends of the DIMM slot to unlock it 3 Align the key of the DIMM module with the receptive point...
Страница 35: ...s Riser cards position the expansion cards at a 90 degree angle allowing them to fit inside the 1U chassis Installing PCI Expansion Cards The riser cards have already been pre installed into the mothe...
Страница 36: ...t from the chassis 3 Install the riser card on the bracket with the two screws provided see Figure 3 13 4 Open the latch on the end of the bracket 5 Install the expansion card by sliding the card into...
Страница 37: ...holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may rele...
Страница 38: ...ndicate the status of the drive In non RAID configurations the status indicator remains off See the table below for details Hard Drive Carrier LED Indicators LED Color State Status Activity LED Blue S...
Страница 39: ...and servers For information on recommended HDDs for AS 1014S WTRT visit the Supermicro website at https www supermicro com products nfo AMD_SP3 cfm pg SS and click AS 1014S WTRT then Drive Options Re...
Страница 40: ...that there are holes in the carrier marked SATA to aid in correct installation 4 Secure the drive to the carrier with four M3 screws These screws are included in the chassis accessory box 5 Insert th...
Страница 41: ...PM1 1 2 JUSBA1 4 1 5 9 JF1 1 2 JSD2 1 3 JSD1 1 3 1 JNCSI1 JUSBRJ45 LED6 A C LED1 LED11 LED12 LED10 LED13 JDB2 JDB1 JWD1 JPL1 JPG1 JUART2 JPB1 1 3 JUART3 JHDT1 JFPGA_SW1 2 7 8 JVRM1 JSLIM3 B1 JSLIM2 JS...
Страница 42: ...e motherboard lift up its top square latch and use gentle force to pull it out of the hole 3 Move and place the standoff plug in the proper hole 4 Insert the M 2 2280 device at a slight angle in the M...
Страница 43: ...lace the air shroud into the chassis 5 Replace the chassis cover plug the power cords into the rear of the power supply and power up the system Checking the Airflow Check the Airflow 1 Make sure there...
Страница 44: ...the system Each fan unit is actually made up of two fans joined back to back which rotate in opposite directions This counter rotating action generates exceptional airflow and is effective in dampenin...
Страница 45: ...herboard may differ from that in the AS 1014S WTRT 6 Reposition the fan housing back over the two mounting posts in the system then reconnect the fan wires to the same fan headers on the motherboard 7...
Страница 46: ...contact information in the Preface The hot swap capability of the power supply modules allows you to replace the failed module without powering down the system Replacing the Power Supply 1 Check the...
Страница 47: ...ight full length expansion card and one low profile card mounted on a riser card and riser bracket The low profile slot may be used for a Supermicro SAS controller card 2 1 Expansion Card Configuratio...
Страница 48: ...e cover 2 Remove the bracket and sections of the chassis in the rear Small screwdriver icons are etched into the chassis pieces to help identify which screws must be removed 3 If necessary attach the...
Страница 49: ...and Component Installation Figure 3 24 Expansion Cards Installed 5 Insert the riser card into the motherboard expansion slot while aligning the riser card bracket with the rear of the chassis Secure...
Страница 50: ...or removing components 4 1 Power Connections Two power connections on the AS 1014S WTRT must be connected to the power supply The wiring is included with the power supply 12V 8 pin ATX XPU Power JPWR1...
Страница 51: ...n headers pins 1 3 are backward compatible with traditional 3 pin fans The onboard fan speeds are controlled by Thermal Management via Hardware Monitoring in the BMC When using Thermal Management sett...
Страница 52: ...iN NT has two dedicated NVMe ports two ports on a slim SAS connector on the motherboard These ports provide high speed low latency PCI E 3 0 x4 connections directly from the CPU to NVMe Solid State SS...
Страница 53: ...CLK 2 GND 3 LFRAME 4 Key 5 LRESET 6 N C 7 LAD3 8 LAD2 9 3 3V 10 LAD1 11 LAD0 12 GND 13 SMB_CLK optional 14 SMB_DAT optional 15 P3V3_STBY 16 SERIRQ 17 GND 18 LP_CLKRUN optional 19 LPC_PD optional 20 LP...
Страница 54: ...1C Riser Slot SXB2 Riser Slot for CPU Slot2 PCI E 4 0 x16 Chassis Intrusion JL1 A Chassis Intrusion header is located at JL1 on the motherboard Attach the appropriate cable from the chassis to the hea...
Страница 55: ...re to use the IPMB I2 C connection on your system IPMB Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection Power SMB Header PWRI2C Power System Management Bus I2C header moni...
Страница 56: ...ated on pins 15 and 16 of JF1 Refer to the table below for pin definitions NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 Refer to the table below for pin defi...
Страница 57: ...ivity Refer to the table below for pin definitions NIC1 NIC2 LED Pin Definitions JF1 Pin Definition 9 11 Vcc 10 12 Ground UID LED The UID LED is on pins 7 and 8 of JF1 Connect the front panel UID LED...
Страница 58: ...ter 4 To turn off the power in the suspend mode press the button for at least 4 seconds Refer to the table below for pin definitions Reset Button The Reset Button connection is located on pins 3 and 4...
Страница 59: ...d descriptions of the various I O ports on the rear of the motherboard Figure 4 2 Rear I O Ports Rear I O Ports Description Description Description 1 COM Port 5 USB 2 3 1 9 VGA Port 2 IPMI LAN Port 6...
Страница 60: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cleari...
Страница 61: ...ignal for the application that hangs Watch Dog must also be enabled in BIOS The default setting is Reset Note When Watch Dog is enabled the user needs to write their own application software to disabl...
Страница 62: ...nt UID LED is located on the front panel When you press the UID switch both rear LED1 and front UID LED indicators will turn on Press the UID switch again to turn off the LED indicators Use this UID I...
Страница 63: ...d unplug the power cable before removing or installing any component s Onboard Power LED Indicator LED Color Definition Off System Off power cable not connected Green System On Power OK M 2 Interface...
Страница 64: ...at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flas...
Страница 65: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...
Страница 66: ...if preferred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the f...
Страница 67: ...Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can r...
Страница 68: ...access monitoring and management There are several BIOS settings that are related to IPMI Supermicro ships standard products with a unique password for the BMC ADMIN user This password can be found o...
Страница 69: ...F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be confi...
Страница 70: ...System Time Use this option to change the system date and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to mov...
Страница 71: ...plays the date when the version of the BIOS ROM used in the system was built CPLD Version This item displays the CPLD version of the BIOS ROM used in the system Memory Information Total Memory This fe...
Страница 72: ...ss the submenu items Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select En...
Страница 73: ...ly reboot the system from a specified boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog Timer...
Страница 74: ...his feature wil schedule an operation for the the security device select TPM Clear to clear any pending operation The options are None and TPM Clear Device Select Selecting TPM 1 2 will restrict suppo...
Страница 75: ...ormation will display Super IO Chip AST2500 Serial Port 1 Configuration Serial Port Select Enabled to enable the selected onboard serial port The options are Disabled and Enabled Device Settings This...
Страница 76: ...t ANSI to use the Extended ASCII Character Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI Bits per second Use thi...
Страница 77: ...Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Disabled and Enabled Putty KeyPad This feature selects the settings for Function Keys an...
Страница 78: ...sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a seria...
Страница 79: ...ader is selected then the Legacy Console Redirection is disabled before booting to the legacy OS If you select Always Enable then the Legacy Console Redirection is enabled for legacy OS systems Defaul...
Страница 80: ...l for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the re...
Страница 81: ...ion Number of Cores Running Processor Family Processor Model Microcode Patch Level L1 Instruction Cache Size Method L1 Data Cache Size Method L2 Data Cache Size Method L3 Cache per Scoket Size Method...
Страница 82: ...tting controls interleave memory blocks across the DRAM chip for node 0 The options are Disabled and Auto BankGroupSwap This setting controls the Bank Group Swap The options are Enabled Disabled and A...
Страница 83: ...restricting the values advertised by the UPstream component in its training sequences When Auto is selected the HW initialized data will be used VGA Priority Use this setting to select between onboard...
Страница 84: ...Support This setting allows you to Enable or Disable IPv4 PXE boot support If disabled IPv4 PXE boot support will not be available Ipv4 HTTP Support This setting allows you to Enable or Disable IPv4...
Страница 85: ...drivers The options are Enabled and Disabled Port 60 64 Emulation Select Enabled for I O port 60h 64h emulation support which in turn will provide complete legacy USB keyboard support for the operati...
Страница 86: ...d SATA devices connected and are detected HTTP Boot Configuration HTTP Boot One Time When the HTTP boot option is created this option when enabled will allow the system to boot via HTTP the first time...
Страница 87: ...n Configure Select Enabled to activate Pv4 network configuration The options are Enabled and Disabled If the item above is set to Enabled the following item will become available for configuration Ena...
Страница 88: ...e changes above IPV6 Network Configuration This section displays configuration features for IPV6 support IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled Confi...
Страница 89: ...e This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format Once the name of the iSCSI Initiator is entered into the system configure the proper settings for the follo...
Страница 90: ...t Interface IPMI settings BMC Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI Status Baseboard Management Controller This item indicates the status of the IPM...
Страница 91: ...onfiguration IPMI LAN Selection This item displays the IPMI LAN setting The default setting is Failover IPMI Network Link Status This item displays the IPMI Network Link status The default setting is...
Страница 92: ...s are Disable and Enable Configure IPV6 Support This section displays configuration features for IPV6 support IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled...
Страница 93: ...BIOS Event settings Enabling Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Erasing Set...
Страница 94: ...abled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This i...
Страница 95: ...ord is erased the User Password will be cleared as well User Password Press Enter to create a new or change an existing User password Password Check Select Setup for the system to check for a password...
Страница 96: ...ault secure keys set by the manufacturer The options are Yes and No Enroll EFI Image This allows the image to run in Secure Boot Mode and enroll SHA256 hash of the binary into an Authorized Signature...
Страница 97: ...dd the DBX from the manufacturer s defaults to the existing DBX Select No to load the DBX from a file The options are Yes and No Authorized TimeStamps Set New Key Select Yes to load the DBT from the m...
Страница 98: ...ystem to boot to an EFI OS after the boot failed from the legacy boot order FIXED BOOT ORDER Priorities This option prioritizes the order of bootable devices that the system to boot from Press Enter o...
Страница 99: ...ation Boot Priorities This feature allows the user to specify which UEFI devices are boot devices UEFI Boot Order 1 NETWORK Drive BBS Priorities This feature allows the user to specify which UEFI netw...
Страница 100: ...ress Enter Save Changes and Reset Select this option to reset the system after saving the changes Save Changes After completing the system configuration changes select this option to save the changes...
Страница 101: ...ser Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from t...
Страница 102: ...ge Unzip and save it 2 Access the IPMI web interface Enter the IP address and log in The default username and password are ADMIN ADMIN For details on IPMI use the link above 3 Click the Maintenance ta...
Страница 103: ...rt Upgrade Dialog Verify Date 1 In the Start Upgrade dialog make sure the three checkboxes are not checked and verify the date of the BIOS file you uploaded before proceeding 2 Click the Start Upgrade...
Страница 104: ...ro com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagno...
Страница 105: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...
Страница 106: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...
Страница 107: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...
Страница 108: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 109: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...
Страница 110: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 111: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...
Страница 112: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 113: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...
Страница 114: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 115: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All co...
Страница 116: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 117: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...
Страница 118: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 119: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...
Страница 120: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 121: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...
Страница 122: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 123: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto ut...
Страница 124: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 125: ...wo PCI E 4 0 x16 slots FHFL with riser card RSC W 66G4 One PCI E 4 0 x16 slot low profile with riser card RSC WR 6 M 2 Interface 2 SATA PCI E 3 0 x2 M 2 Form Factor 2280 22120 M 2 Key M key Motherboar...
Страница 126: ...11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Directive 2012 19 EU Perchlo...
Страница 127: ...he recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system pow...
Страница 128: ...different machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website...
Страница 129: ...you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed with...
Страница 130: ...ot to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built...
Страница 131: ...rupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power suppl...
Страница 132: ...aff You can download a crash dump of status information using IPMI The IPMI manual is available at https www supermicro com solutions IPMI cfm Check IPMI Error Log 1 Access the IPMI web interface 2 Cl...
Страница 133: ...message will appear 3 Click the Download button and a Save As dialog appears 4 Save the zipped dump file noting the name and location Note The System auto reset check box dictates behavior after an IE...