background image

 

 
 

 

Model 

RDO-5 

Power Input: 

220-240 VAC 50/60Hz 

Motor: 

18 VAC 

Courtesy light time:   

3 minutes 

Relative humidity: 

<90 % 

Reception frequency:   

433.92 MHz 

Transmitter power:   

12V Battery 

Working temperature: 

-20 C 

– 40 C 

Open and close force: 

600 N 

Decoding: 

Rolling code 

Lamp: 

LED, 12V DC 

Operator limits travel: 

  6.5 circles of door drum wheel 

 

Symptom 

Possible reason 

Solution 

The door will not operate from 
control box

 

Power not switch on

 

Check power is on to control unit(Red 
LED illuminated)

 

Mains plug problem 

Plug fully engaged on the control box 
and motor wiring connections properly 
engaged 

“beep, beep.....” from buzzer, and 
LED displays ”E2” error code 
 
 

Motor fault 

Push the manual release lever up 

Change a new motor 

Change a new rotary encoder 

TECHNICAL SPECIFICATIONS 

 

TROUBLE SHOOTING GUIDE 

 

Содержание RDO-5

Страница 1: ...RDO 5 Roller Door Opener Your Automatic Choice Installation Instructions and User Guide ...

Страница 2: ...indirectly arise out of any of the following actions a Failure to install the Opener in accordance with the installation instructions herein contained b The Garage Door striking a moving object c The Opener being used on other than a maximum 4 car residential application d Installing the Opener on an improperly balanced and or poorly functioning and or miss aligned Garage Door e Manually releasing...

Страница 3: ...ed to a properly earthed general purpose 220 240V power outlet Locate the control box A within site of the garage door and B at a minimum height of 1 5 meters above the ground so that it remains out of the reach of small children and C away from all moving parts of the door Affix the entrapment warning label in a prominent location next to the garage door After installing and adjusting the Opener ...

Страница 4: ... DRUM WHEEL The door curtain must be secured to the drum wheel with suitable fasteners With the door in the fully closed position mark the curtain at points A and B CHECK OPERATION OF THE DOOR Before beginning the installation of the Opener check the operation of the door The door must be well balanced and operate smoothly and freely When opened to between 900 1200mm from the floor and released th...

Страница 5: ... assembly is fully engaged with drum wheel spokes Clamp shaft to mounting bracket using U Bolts supplied Disengage the motor drive by pulling the manual release lever downwards Ensure locking bars if fitted are removed and keys removed from the lock CONTROL BOX Mount the control box on a smooth flat surface The area must be completely free of exposure to water either direct rain garden hose sprink...

Страница 6: ... sensitivity 2 CODE Button Transmitter code set 3 UP Button Limit mode set 4 DOWN Button Limit mode set Circuit Board Connections fig 7 5 Battery Backup connection terminal 6 Motor connection terminal 7 Hall sensor terminal 8 Control board terminal 9 External device connection terminal SETTINGS AND ADJUSTMENTS Fig 6 Fig 7 ...

Страница 7: ...tion If using the standard right side installation this step can be ignored 2 Setting Open and Close Limits a Move the door to the halfway position and engage the opener using the release cord b Press and hold SET button until the LED displays the number 1 c Press and hold UP button the door will travel to the open position release the button when the door has reached the desired open position d F...

Страница 8: ... increase by 1 minute the maximum time is 9 minutes Press DOWN once the auto close time will decrease by 1 minute The LED will display the current set value c The Auto Close function will be disabled when the setting is 0 d Press SET to store your setting Note Auto close is only available when door is at its fully open position When using auto close photo beams must be fitted 6 Coding and Deleting...

Страница 9: ...travel 6 5 circles of door drum wheel Symptom Possible reason Solution The door will not operate from control box Power not switch on Check power is on to control unit Red LED illuminated Mains plug problem Plug fully engaged on the control box and motor wiring connections properly engaged beep beep from buzzer and LED displays E2 error code Motor fault Push the manual release lever up Change a ne...

Страница 10: ...ease the safety reverse force The door reverses automatically when closing The moving force of the motor is set too low Increase the safety reverse force There could be an obstruction under the door Remove obstruction The door stops automatically when opening The moving force of the motor is set too low Increase the safety reverse force The operator can be controlled by O S C button but not the re...

Страница 11: ...nction The motor rotates but the door doesn t move Motor put into manual mode Push the manual release lever up The door closes when pressing UP during limit setting Left right installation error Chang the installation direction according to left right installation setting in the instruction manual ...