background image

 

 
 

 

 

3.   Adjusting Safety Force (Sensitivity) 

 

Force setting range is between 1 

– 9 

 
a.  Press and hold 

SET

 until the LED displays number

 3

. Factory setting is 3.

 

b.  Press

 UP 

to increase the force by one degree and 

DOWN 

to decrease the force by one 

degree. Maximum degree is

 9

 and the minimum degree is 

1

c.  Press 

SET

 to store your setting.   

 

4. Photo beam setting (OPTIONAL) 

 

Make sure the photo beams have been installed correctly before setting the Photo beam 

function. 

 
a.  Press and hold 

DOWN

 until the LED displays 

II

b.  Press the

 UP button 

once. The LED displays

 H

. Photo beam function is on. Press the 

DOWN

 button the LED displays

 II 

to cancel Photo Beam function. 

c.  Press

 SET 

to store your setting. 

 

5. Setting Auto Close Function 

 

a.  Press and hold 

UP 

until the LED displays 

0. 

b.  Press 

UP 

once, the auto close time will increase by 

minute, the maximum time is 9 

minutes. Press 

DOWN 

once, the auto close time will decrease by 

minute. The LED will 

display the current set value.

 

c.  The Auto Close function will be disabled when the setting is

 0

.

 

d.  Press 

SET 

to store your setting.

 

 

Note: Auto close is only available when door is at its fully open position. When using 

auto close, photo beams must be fitted.

 

 

6. Coding and Deleting Transmitters (Maximum 20) 

 

a.  Momentarily press

 CODE button.

 A Red dot will appear on the display. 

b.  Press and release a button on the transmitter, the Red dot will disappear, press the 

same button a second time, the Red dot will flash and then be replaced by a 

U

 on the 

LED display. Transmitter is programmed successfully. 

c.  Repeat step b. to code a maximum of 20 transmitters. 
d.  To delete transmitters, press and hold 

CODE

, the LED display dot will flash, keep 

holding for approximately 8 seconds until the LED display flashes a 

C

. Release button. 

All transmitters are now deleted. 

 
 

 

SETTINGS AND ADJUSTMENTS 

 

Содержание RDO-5

Страница 1: ...RDO 5 Roller Door Opener Your Automatic Choice Installation Instructions and User Guide ...

Страница 2: ...indirectly arise out of any of the following actions a Failure to install the Opener in accordance with the installation instructions herein contained b The Garage Door striking a moving object c The Opener being used on other than a maximum 4 car residential application d Installing the Opener on an improperly balanced and or poorly functioning and or miss aligned Garage Door e Manually releasing...

Страница 3: ...ed to a properly earthed general purpose 220 240V power outlet Locate the control box A within site of the garage door and B at a minimum height of 1 5 meters above the ground so that it remains out of the reach of small children and C away from all moving parts of the door Affix the entrapment warning label in a prominent location next to the garage door After installing and adjusting the Opener ...

Страница 4: ... DRUM WHEEL The door curtain must be secured to the drum wheel with suitable fasteners With the door in the fully closed position mark the curtain at points A and B CHECK OPERATION OF THE DOOR Before beginning the installation of the Opener check the operation of the door The door must be well balanced and operate smoothly and freely When opened to between 900 1200mm from the floor and released th...

Страница 5: ... assembly is fully engaged with drum wheel spokes Clamp shaft to mounting bracket using U Bolts supplied Disengage the motor drive by pulling the manual release lever downwards Ensure locking bars if fitted are removed and keys removed from the lock CONTROL BOX Mount the control box on a smooth flat surface The area must be completely free of exposure to water either direct rain garden hose sprink...

Страница 6: ... sensitivity 2 CODE Button Transmitter code set 3 UP Button Limit mode set 4 DOWN Button Limit mode set Circuit Board Connections fig 7 5 Battery Backup connection terminal 6 Motor connection terminal 7 Hall sensor terminal 8 Control board terminal 9 External device connection terminal SETTINGS AND ADJUSTMENTS Fig 6 Fig 7 ...

Страница 7: ...tion If using the standard right side installation this step can be ignored 2 Setting Open and Close Limits a Move the door to the halfway position and engage the opener using the release cord b Press and hold SET button until the LED displays the number 1 c Press and hold UP button the door will travel to the open position release the button when the door has reached the desired open position d F...

Страница 8: ... increase by 1 minute the maximum time is 9 minutes Press DOWN once the auto close time will decrease by 1 minute The LED will display the current set value c The Auto Close function will be disabled when the setting is 0 d Press SET to store your setting Note Auto close is only available when door is at its fully open position When using auto close photo beams must be fitted 6 Coding and Deleting...

Страница 9: ...travel 6 5 circles of door drum wheel Symptom Possible reason Solution The door will not operate from control box Power not switch on Check power is on to control unit Red LED illuminated Mains plug problem Plug fully engaged on the control box and motor wiring connections properly engaged beep beep from buzzer and LED displays E2 error code Motor fault Push the manual release lever up Change a ne...

Страница 10: ...ease the safety reverse force The door reverses automatically when closing The moving force of the motor is set too low Increase the safety reverse force There could be an obstruction under the door Remove obstruction The door stops automatically when opening The moving force of the motor is set too low Increase the safety reverse force The operator can be controlled by O S C button but not the re...

Страница 11: ...nction The motor rotates but the door doesn t move Motor put into manual mode Push the manual release lever up The door closes when pressing UP during limit setting Left right installation error Chang the installation direction according to left right installation setting in the instruction manual ...