SuperiorFireplaces.us.com
126861-01L
26
PARTS
MODELS VRL4543ZEN & VRL4543ZEP
11
7
4
3
8
14
15
16
17
18
19
20
24
21
5
22
23
6
2
1
13
10
9
12
Cat. No.
Description
F1186
VRL4543ZEN
F1187
VRL4543ZEP
Страница 1: ...stion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual PFS US Report No F11 054 WARNING FIRE OR EXPLOSION HAZARD Failure to follow safe...
Страница 2: ...bited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases IMPORTANT Read this owner s manual car...
Страница 3: ...ture 10 This fireplace needs fresh air ventilation to run properly This fireplace has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fireplace if not enough fresh air is...
Страница 4: ...he individual manual shut off must be a T handle type valve Unvented appliances may NOT be installed in bedrooms or bathrooms A working smoke detector must be installed in the area where vent free app...
Страница 5: ...hich the appliances are installed through openings not furnished with doors are considered a part of the unconfined space This appliance shall not be installed in a confined space or unusually tight c...
Страница 6: ...ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoors See Ventilation Air From Outdoors C Install a lower Btu Hr fireplace if lower Btu Hr siz...
Страница 7: ...ealer where you bought fireplace for proper type fireplace WARNING This appliance is equipped for either natural gas or propane LP gas but not both Gas type is indicated on the rating plate Field conv...
Страница 8: ...D 16 5 2 E 14 A B C D E 1 2 3 4 5 Wall Supplied firebox hood must be used at all times Note All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf Noncombustible ma...
Страница 9: ...1 2 29 5 8 29 5 8 16 3 8 7 1 8 1 7 8 8 1 4 44 1 8 1 1 55 1 8 52 47 16 1 2 11 3 4 8 1 4 5 8 INSTALLATION Continued Figure 8 VRL4543 Series Dimensions Electrical Outlet Gas Line Access Gas Line Access...
Страница 10: ...propane LP supply This fireplace requires anexternalregulator notsupplied Installtheexternal regulatorbetweenthefireplaceandpropane LPsupply WARNING Never connect natural gas fireplace to private non...
Страница 11: ...diment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fireplace gas controls If sediment trap is not installed or is...
Страница 12: ...lve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 13 2 Pressurize supply piping system by either o...
Страница 13: ...a guide screw the rear panel to the fireplace as shown in Figure 16 INSTALLING HOOD 1 Loosen screws at top of face opening and slide hood through screws as shown in Figure 17 2 Tighten screws securing...
Страница 14: ...ont of the fireplace unscrew 4 corner brackets from the firebox top See Figure 21 2 Remove 2 side walls and then the rear wall Discard rear wall 3 Replace 2 side walls and reinstall the corner bracket...
Страница 15: ...ner shuts OFF Figure 26 Gas Module Right Side Figure 27 Gas Module Left Side Remote Control Feature The module has a built in remote control receiver that allows the user to program the remote transmi...
Страница 16: ...supplied with the unit into the battery compart ment It is recommended that ALKALINE batteries always be used for this product Be sure the batteries are installed with the and ends facing the correct...
Страница 17: ...tory default or degrees C Press the UP and DOWN Buttons simultaneously to change between degrees F and C SET TEMP While in THERMOSTAT mode press the UP or DOWN Button to change the SET TEMP 45 90 deg...
Страница 18: ...Flame A setting number will flash in the FLAME Zone REMOTE CONTROL OPERATION Continued LIGHT ADJUSTMENT Transmits a light setting command to the control module to adjust the light output level Availa...
Страница 19: ...is appliance requires 120V electricity for normal operation Control module should be plugged into electrical outlet located underneath firebox bottom Back up battery supply is available for power outa...
Страница 20: ...ecommend using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the direct...
Страница 21: ...the fireplace running Some burner flame holes may become blocked by debris or rust with no flame present If so turn off fireplace and let cool Remove blockage Blocked burner flame holes will create so...
Страница 22: ...ot Main HI LO DC Motor Drive Light Module Black Black Brown Red Orange Orange To Ground Igniter Sensor PILOT BATTERY PACK WIRING DIAGRAM Black Blk White SIZE AA SIZE AA SIZE AA SIZE AA Blk Brown Yello...
Страница 23: ...ontact local propane LP gas company 3 Clean ODS pilot see Cleaning and Main tenance Page 20 or replace ODS pilot assembly 4 Replace gas regulator 1 Contact local natural or propane LP gas company 2 Cl...
Страница 24: ...cting while cooling 1 Burner orifice is clogged or damaged 2 Damaged burner REMEDY 1 Check burner for dirt and debris If found clean burner see Cleaning and Mainte nance Page 20 1 Refer to Air for Com...
Страница 25: ...LP only 3 Gas leak See Warning statement above 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve or gas co...
Страница 26: ...SuperiorFireplaces us com 126861 01L 26 PARTS MODELS VRL4543ZEN VRL4543ZEP 11 7 4 3 8 8 8 8 14 15 16 17 18 19 20 24 21 5 22 23 6 2 1 13 10 9 12 Cat No Description F1186 VRL4543ZEN F1187 VRL4543ZEP...
Страница 27: ...694 Burner Gasket 2 14 J6737 Electronic Access Cover 1 15 J8032 Insulation Heatshield 1 16 J6718 Module Extension 1 17 J6570 Bracket Valve Components 1 18 J6738 Insulation Heatshield 1 19 RP125072 03...
Страница 28: ...SuperiorFireplaces us com 126861 01L 28 PARTS MODELS VRL4543ZEN VRL4543ZEP 1 4 6 2 8 9 7 5 3 5 11 12 13 14 10 7 8...
Страница 29: ...d by IHP Use of non approved parts can result in poor performance and safety hazards KEY NO CATALOG NO DESCRIPTION VRL4543ZEN F1186 VRL4543ZEP F1187 QTY 1 J6630 Top Spacer 4 2 J6566 Top Nailing Flange...
Страница 30: ...ace Trim for 43 Linear Fireplace Aged Silver F1038 DFT43AC Decorative Face Trim for 43 Linear Fireplace Aged Copper LINEAR SEE THRU CONVERSION KITS Not Shown F1030 LVSTI Linear VF See Thru Conversion...
Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...
Страница 32: ...tributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products P N 126861 01 Rev L 02 2019 1769 East Lawrence Street Russellville AL 35654 SuperiorFireplaces us com Record th...