background image

TC30 
COUNTRY HOME
BURNER KIT 
INSTRUCTIONS

(NATURAL GAS ONLY)

PART#

TC30.NG02CN
For TC30 Series C

130411-12 TC30.NG02CN 

5056.42902

 INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

These instructions are supplementary to the Installation and 
Operating Instructions supplied with the fi replace and should be 
kept together. Refer to the Installation and Operating Instructions 
for proper gas supply, safety requirements and operating 
instructions

Содержание TC30.NG02CN

Страница 1: ...e this manual with the appliance CONSUMER Retain this manual for future reference These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions ...

Страница 2: ...CKAGE EMBER MATERIAL LOG GRATE 1 Place the keyhole slots in the burner overthetwoscrewslocatedinthefirebox base Fig 1 1a 2 Slide the burner back to engage the screws in the small part of the keyhole slot and tighten screws Fig 1b 3 Remove access cover from side of firebox Fig 1c Fig 1a Fig 1b SCREWS Fig 1 Fig 1c ...

Страница 3: ...plate and gasket to the firebox 2 screws Attach the ignition and sensor wires to the module Red end to the connector marked by the reddot whiteendtotheconnectormarked by the white dot Fig 2 Fig 3 Fig 2 Burner Grate Installation RED END TO RED DOT WHITE END TO WHITE DOT MODULE Fig 3 ...

Страница 4: ...nd tighten Fig 3b Ensure the connections are gas tight Conceal the spark and sensor wires below the supply tubes A panel set must now be installed See InstallationandOperatingInstructions manual for details 6 Position the slots of the grate securing brackets over the holes in the floor shield and secure with the two screws Fig 4 Fig 3b ...

Страница 5: ... leaveitloose for best performance Fill the burner pan level with the top of the pan at rear andgraduallyslopeforwardtothefireboxfloor at the front covering both burner tubes Place remaining ember material outside of the burner pan as desired to cover up gas lines and brackets Note Ember material placement and amount will affect flame appearance More ember material results in lower flame height Ad...

Страница 6: ...re Unpack and inspect log set There should be a total of seven logs Position the logs as indicated by the following pictures The three main logs have holes and or pins Engage each pin in the correspond ing holes The four smaller logs do not have holes or pins They rest in position Locate as per the diagrams fig 6 13 Log Placement Fig 6 Fig 7 1 2 ...

Страница 7: ...TC30 NG02CN 130411 12 7 Fig 8 Fig 9 4 3 ...

Страница 8: ...8 TC30 NG02CN 130411 12 Fig 10 Fig 11 5 6 ...

Страница 9: ...02CN 130411 12 9 Fig 12 Fig 13 3 2 1 5 6 7 Note Improper placement of logs will cause sooting on internal parts and glass The logs may need to be repositioned slightly to avoid excessive flame impingement 4 7 ...

Страница 10: ...e plug Thread sealant will be required to ensure a gas tight connection Correct gas pressure requirement Supply Pressure Natural Gas Min Pressure 5 0 WC For purpose of input adjustment Max Pressure 13 9 WC Manifold Pressure Maximum 3 8 WC Minimum 2 1 WC SUPPLY PRESSURE MANIFOLD PRESSURE Fig 16 Note Totestthegaspressure turnoffthe gassupplybeforeremovingtheblanking plug from the supply pressure tes...

Страница 11: ...er may also be opened to enhance the ember material glow and lessen the flame height Burner Flame Adjustment Caution Proper air shutter setting is a must The flame should be just orange and lazy It should NEVER be set to create sooting on internal parts and glass Fig 18 PRIMARY AIR SHUTTER Shown in closed position To Adjust See Fig 18 1 Open and remove window frame and set aside See Window Frame R...

Страница 12: ...TUBE 5019 225 1 BURNER ASSEMBLY 1a GRATE 1b AIR DEFLECTOR 1c BURNER TRAY 1d PILOT SHIELD 1e BLOCKER PLATE 1f MANIFOLD 1g 1 2 PIPE TO 1 2 TUBE CONNECTION 1h PILOT BRACKET 1i HEAT SHIELD 1j HEAT SHIELD INSULATION KIT CONTENTS 2 7 PCS LOG SET 2a BASE LOG 2b TOP LEFT LOG 2c TOP RIGHT LOG 2d CENTER CHUNK 2e BOTTOM LHS CHUNK 2f BOTTOM CENTER CHUNK 2g BOTTOM RHS CHUNK 3 ORIFICE NATURAL GAS 32 4 PILOT ASS...

Страница 13: ...TC30 NG02CN 130411 12 13 ...

Страница 14: ...14 TC30 NG02CN 130411 12 ...

Страница 15: ...TC30 NG02CN 130411 12 15 ...

Страница 16: ...Technical support 1 250 748 1184 Web site www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada ...

Отзывы: