Superior VRL4543ZEN Скачать руководство пользователя страница 15

SuperiorFireplaces.us.com

126861-01L

15

INSTALLATION 

Continued

GLASS PEBBLE INSTALLATION

 WARNING: Do not change or substitute glass 

pebbles provided with this fireplace. If replacing, use 

only replacement glass pebbles. See Parts

 Page 27

.

 WARNING: Do not block pilot ports with glass 

pebbles.

 WARNING: Do not place the glass pebbles on 

the burner, only on the burner tray as illustrated in 

Figure 25.

REPLACING LIGHT BULBS

1.  Unplug power

2.  Remove access door 

(see 

Figure 24, Page 14

).

3.  Remove glass panel if installed 

(see 

Figure 25a

)

.

4.  Remove rear interior wall 

(see 

Figure 21, Page 14

).

5.  Remove glass Pebbles

 (see 

Figure 25

)

.

6.  Remove six screws holding pebble pan.

7.  Using a small slotted screwdriver, carefully slide it under edge 

of light cover and pry it open.

8.  Pull bulb out carefully and replace with bulb G9 120V/20W.

9.  To replace, follow steps in the reverse order.

GAS CONTROL MODULE SYSTEM

The module has 2 special features built into the system.

Continuous Pilot Feature

This allows the change from a spark to pilot system to a standing 

pilot system
1. There is a switch located on the right side of the module that reads 

CONTINUOUS PILOT ON/OFF. This switch selects the pilot's mode of 

operation 

(

Figure 26

).

2. When the continuous pilot switch is in the OFF position and the appli-

ance rocker switch is turned ON, the pilot will spark and light. When 

the appliance rocker switch is turned OFF, the pilot will shut OFF when 

the main burner shuts OFF.

3. When the continuous pilot switch is in the ON position and the appli-

ance rocker switch is turned ON, the pilot will spark and light. When 

the appliance rocker switch is turned OFF, the pilot will stay ON when 

the main burner shuts OFF.

Figure 26 - Gas Module Right Side

Figure 27 - Gas Module Left Side

Remote Control Feature

The module has a built in remote control receiver that allows the 

user to program the remote transmitter at any time during or after 

the installation of the burner.
1. There is a switch located on the right side of the module that reads 

REMOTE/OFF 

(

Figure 27

).

2. When the remote/off switch is in the OFF position, the burner will 

operate from the rocker switch or wall switch connected to the 

two BROWN wires on the module.

3. When the remote/off is in the REMOTE position the burner will 

operate from the Remote Control transmitter.

Figure 25a - Installing/Removing Glass Panel

Clear glass pebbles are included with your fireplace. Install the glass 

pebbles before installation of optional Draft Shield Kit, LV43DS 

(F1031).
1.  Place glass pebbles in a single layer evenly on the pebble pan. 

Make certain that the correct media is used. If crushed glass 

or other media is used, replaced it with the proper media listed 

on the price list. Make certain the media is placed precisely as 

indicated in this instruction manual (single layer of pebbles in 

straight rows) and all glass remains on the pebble tray with no 

glass at all on the burner.

OPTIONAL DRAFT SHIELD KIT INSTALLATION (F1031)

Note:

 Barrier kit cat. no. F2882 is required when installing this kit.

The glass panel assembly should be installed after the fireplace is 

completely framed and finished. The brackets are attached to the front 

side face of the fireplace using two screws as shown in

 Figure 25a. 

Position the glass panel in the bracket so that it is securely in place.

Continuous Pilot

Off/On Switch

Remote/Off 

Switch

“S” Pilot 

Connection

“I” Pilot 

Connection

ADJ.

Figure 25 - Placing Glass Pebbles

Place Glass 

Pebbles on the 

pebble tray in a 

single orderly 

layer.

Glass Panel

Bracket

Screws

 

Learn Button

AUX Connection

Содержание VRL4543ZEN

Страница 1: ...stion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual PFS US Report No F11 054 WARNING FIRE OR EXPLOSION HAZARD Failure to follow safe...

Страница 2: ...bited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases IMPORTANT Read this owner s manual car...

Страница 3: ...ture 10 This fireplace needs fresh air ventilation to run properly This fireplace has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fireplace if not enough fresh air is...

Страница 4: ...he individual manual shut off must be a T handle type valve Unvented appliances may NOT be installed in bedrooms or bathrooms A working smoke detector must be installed in the area where vent free app...

Страница 5: ...hich the appliances are installed through openings not furnished with doors are considered a part of the unconfined space This appliance shall not be installed in a confined space or unusually tight c...

Страница 6: ...ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoors See Ventilation Air From Outdoors C Install a lower Btu Hr fireplace if lower Btu Hr siz...

Страница 7: ...ealer where you bought fireplace for proper type fireplace WARNING This appliance is equipped for either natural gas or propane LP gas but not both Gas type is indicated on the rating plate Field conv...

Страница 8: ...D 16 5 2 E 14 A B C D E 1 2 3 4 5 Wall Supplied firebox hood must be used at all times Note All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf Noncombustible ma...

Страница 9: ...1 2 29 5 8 29 5 8 16 3 8 7 1 8 1 7 8 8 1 4 44 1 8 1 1 55 1 8 52 47 16 1 2 11 3 4 8 1 4 5 8 INSTALLATION Continued Figure 8 VRL4543 Series Dimensions Electrical Outlet Gas Line Access Gas Line Access...

Страница 10: ...propane LP supply This fireplace requires anexternalregulator notsupplied Installtheexternal regulatorbetweenthefireplaceandpropane LPsupply WARNING Never connect natural gas fireplace to private non...

Страница 11: ...diment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fireplace gas controls If sediment trap is not installed or is...

Страница 12: ...lve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 13 2 Pressurize supply piping system by either o...

Страница 13: ...a guide screw the rear panel to the fireplace as shown in Figure 16 INSTALLING HOOD 1 Loosen screws at top of face opening and slide hood through screws as shown in Figure 17 2 Tighten screws securing...

Страница 14: ...ont of the fireplace unscrew 4 corner brackets from the firebox top See Figure 21 2 Remove 2 side walls and then the rear wall Discard rear wall 3 Replace 2 side walls and reinstall the corner bracket...

Страница 15: ...ner shuts OFF Figure 26 Gas Module Right Side Figure 27 Gas Module Left Side Remote Control Feature The module has a built in remote control receiver that allows the user to program the remote transmi...

Страница 16: ...supplied with the unit into the battery compart ment It is recommended that ALKALINE batteries always be used for this product Be sure the batteries are installed with the and ends facing the correct...

Страница 17: ...tory default or degrees C Press the UP and DOWN Buttons simultaneously to change between degrees F and C SET TEMP While in THERMOSTAT mode press the UP or DOWN Button to change the SET TEMP 45 90 deg...

Страница 18: ...Flame A setting number will flash in the FLAME Zone REMOTE CONTROL OPERATION Continued LIGHT ADJUSTMENT Transmits a light setting command to the control module to adjust the light output level Availa...

Страница 19: ...is appliance requires 120V electricity for normal operation Control module should be plugged into electrical outlet located underneath firebox bottom Back up battery supply is available for power outa...

Страница 20: ...ecommend using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the direct...

Страница 21: ...the fireplace running Some burner flame holes may become blocked by debris or rust with no flame present If so turn off fireplace and let cool Remove blockage Blocked burner flame holes will create so...

Страница 22: ...ot Main HI LO DC Motor Drive Light Module Black Black Brown Red Orange Orange To Ground Igniter Sensor PILOT BATTERY PACK WIRING DIAGRAM Black Blk White SIZE AA SIZE AA SIZE AA SIZE AA Blk Brown Yello...

Страница 23: ...ontact local propane LP gas company 3 Clean ODS pilot see Cleaning and Main tenance Page 20 or replace ODS pilot assembly 4 Replace gas regulator 1 Contact local natural or propane LP gas company 2 Cl...

Страница 24: ...cting while cooling 1 Burner orifice is clogged or damaged 2 Damaged burner REMEDY 1 Check burner for dirt and debris If found clean burner see Cleaning and Mainte nance Page 20 1 Refer to Air for Com...

Страница 25: ...LP only 3 Gas leak See Warning statement above 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve or gas co...

Страница 26: ...SuperiorFireplaces us com 126861 01L 26 PARTS MODELS VRL4543ZEN VRL4543ZEP 11 7 4 3 8 8 8 8 14 15 16 17 18 19 20 24 21 5 22 23 6 2 1 13 10 9 12 Cat No Description F1186 VRL4543ZEN F1187 VRL4543ZEP...

Страница 27: ...694 Burner Gasket 2 14 J6737 Electronic Access Cover 1 15 J8032 Insulation Heatshield 1 16 J6718 Module Extension 1 17 J6570 Bracket Valve Components 1 18 J6738 Insulation Heatshield 1 19 RP125072 03...

Страница 28: ...SuperiorFireplaces us com 126861 01L 28 PARTS MODELS VRL4543ZEN VRL4543ZEP 1 4 6 2 8 9 7 5 3 5 11 12 13 14 10 7 8...

Страница 29: ...d by IHP Use of non approved parts can result in poor performance and safety hazards KEY NO CATALOG NO DESCRIPTION VRL4543ZEN F1186 VRL4543ZEP F1187 QTY 1 J6630 Top Spacer 4 2 J6566 Top Nailing Flange...

Страница 30: ...ace Trim for 43 Linear Fireplace Aged Silver F1038 DFT43AC Decorative Face Trim for 43 Linear Fireplace Aged Copper LINEAR SEE THRU CONVERSION KITS Not Shown F1030 LVSTI Linear VF See Thru Conversion...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 32: ...tributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products P N 126861 01 Rev L 02 2019 1769 East Lawrence Street Russellville AL 35654 SuperiorFireplaces us com Record th...

Отзывы: