EMBER PLACEMENT
INSTALLATION
Continued
Figure 31 - Placement of Rock Wool (shown with Platinum Bright Embers)
Figure 30 - Platinum Bright Embers
Rock Wool
Flat Front Burner
Ember Material
WARNING: Do not use any other
ember material not supplied with
this unit.
WARNING: Do not operate unit
without ember material correctly in
place as shown in Figures 49 & 50. Do
NOT place ember material anywhere
else on the unit. Use only ember mate-
rial supplied with unit. Excessive or
incorrectly placed ember material may
produce carbon monoxide or soot.
If replacement embers are needed,
the replacement embers must be
purchased from IHP. See page 41 for
part numbers.
LAVA ROCK PLACEMENT
•
Rock Wool placement.
Place rock wool
material on front flat burner in areas away
from ports as shown in Figure 31.
• Add lava rock; Lava rock may cover 1/2
inch of the front burner(flat metal ember
pan burner) but shall not be allowed to
come in contact with either the burner
ports or flame around base of heater if de
-
sired.
DO NOT place rock or additional
logs on front burner or on logs except
as directed above.
Placing any material
on unit other than ember material on front
burner may result in production of carbon
monoxide or soot. A switch log is included
with each log set. This log is designed to
house a switch on remote ready models.
On variable remote models, this switch is
not needed. The log can be placed on the
floor of the fireplace to enhance the look
of the log set. Use lava rock to hide wires
from switch/log to control valve. Place
switch/log so the switch is easy to access.
Two ember materials are supplied with this
log set. Platinum Bright Embers give a bright
glow appearing as hot coals. Should embers
need replacing, see
Accessories
, page 39.
•
Platinum Bright Ember placement.
Add embers to front, flat burner. Gently
remove embers from bag. Separate
pieces of ember material and place on
surface of flat burner just behind hori
-
zontal ports as shown in Figure 30.
WARNING: All previously