background image

SUPERIOR

®

 B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS

Packaging .........................................Page  2
Introduction ......................................Page  2
General Information ..........................Page  2
Gas Pressure Requirements ..............Page  4
Orifice Sizes ......................................Page  4
Gas Valve Diagrams ..........................Page  4
Requirements for the Commonwealth  

      of Massachusetts  .......................Page  4
New York City Approval .....................Page  4
Cold Climate Insulation .....................Page  5
Location ............................................Page  5
Vent Termination Clearances:
   Multiple Terminations.....................Page  6
   Gas Vent Rule ................................Page  6
Minimum Clearances to Combustibles:
   Appliance and Vent Clearances ......Page   7
   Hearth Extension ............................Page   7
   Wall Finishes / Surrounds /  

      Mantels .......................................Page   7
Pre-Installation Steps (Remove 

      Glass Enclosure Panel) ...............Page  8
Typical Installation Sequence ............Page  8
Detailed Installation Steps:
Step 1.  Construct Appliance  

 

   Framing ............................Page  8

 

Fireplace and Framing 

 

   Specifications ...................Page  9

Step 2.  Route the Gas Line ..............Page  11
Step 3.  Install Venting System and 

 

   Exterior Termination .........Page  11

Step 4.  Install Field Wiring ..............Page  12
 

Wiring Diagrams .................Page  13

Step 5.  [Optional] Install Outside  

 

  Combustion Air Kit ............Page  14

 

Installation Accessories ......Page  14

Step 6.  Connect the Gas Line ..........Page  15
Step 7.  Verify Appliance  

 

   Operation .........................Page  16

Step 8.  Install Volcanic Stone, Glowing 

 

   Embers, and Logs  ...........Page  17

 

SLBV-35 Log Placement .....Page  18

 

SLBV-40 Log Placement .....Page  19

Step 9.  Install the Glass Enslosure  

 

   Panel  ...............................Page  20

Step 10. Burner Air Shutter  

 

   Adjustments .....................Page  20

Step 11. Perform Spillage Test ..........Page  22
 

Manually-Reset Safety Limit 

 

   Switch ..............................Page  22

Step 12. Install Hood .........................Page  23
Step 13. Finishing Requirements ......Page  23
Step 14. Attach Safety-in-Operation

    Warnings ......................................Page  24
Gas Conversion Kits
 .........................Page  25

PACKAGING

The assembled vented gas fireplace is packaged 

with the following items:
1 - One log set located in firebox area.

2 - One  envelope  containing  the  literature 

package  which  consists  of  the  care  and 

operations  manual,  installation  instruc-

tions,  safety-in-operation  warning  labels 

and  warranty;  envelope  is  located  in  the 

control compartment.

3 - One hood located behind the glass enclo-

sure panel assembly.

4 - One bag of decorative volcanic stone located 

in the lower control compartment.

5 - One bag of glowing embers located in the 

lower control compartment.

INTROdUCTION 

The 

Millivolt

  appliances  have  a  millivolt  gas 

control valve with piezo ignition system. 
The 

Electronic

  appliances  have  a  battery 

backed-up electronic intermittent pilot ignition 

system. No external electrical power is required 

to  operate  these  appliances;  however,  120V 

AC is recommended (see Step 4, “Install Field 

Wiring,” on 

Page 12

).

Use Only These Approved Vent Components:  

These vented gas fireplaces are designed for 

residential applications. They must be installed 

with  approved  Type-B  double-wall  vent  pipe 

systems and a listed vent termination routed 

to the outside atmosphere. Use only the proper 

size listed below.
•  4" B-Vent for 35" models and 5" B-Vent  for 

40" models.

GENERAL INfORMATION

Children and adults should be alerted to 

the hazards of high surface temperature 

and should stay away to avoid burns or 

clothing ignition. 

Les  enfants  et  les  adultes  devraient 

être infor-més des dangers que posent 

les températures de surface élevées 

et se tenir à distance afin d’éviter des 

brûlures  ou  que  leurs  vêtements  ne 

s’enflamment.

dO NOT ATTEMPT TO ALTER OR 

MOdIfY THE CONSTRUCTION Of THE 

APPLIANCE OR ITS COMPONENTS. ANY 

MOdIfICATION OR ALTERATION MAY 

VOId THE WARRANTY, CERTIfICATION, 

ANd LISTINGS Of THIS UNIT.

       WARNING 

Young children should be care-

fully supervised when they are 

in the same room as the appli-

ance. Toddlers, young children 

and others may be susceptible 

to accidental contact burns.  

A physical barrier is recom-

mended if there are at risk 

individuals in the house.  To 

restrict access to a fireplace 

or stove, install an adjustable 

safety gate to keep toddlers, 

young children and other at 

risk individuals out of the room 

and away from hot surfaces.

       AVERTISSEMENT 

Les jeunes enfants devraient être 

surveillés étroitement lorsqu’ils 

se trouvent dans la même pièce 

que l’appareil. Les tout petits, 

les jeunes enfants ou les adultes 

peuvent subir des brûlures s’ils 

viennent en contact avec la sur-

face chaude.  Il est recommandé 

d’installer une barrière physique 

si des personnes à risques habi-

tent la maison. Pour empêcher 

l’accès à un foyer ou à un poêle, 

installez une barrière de sécu-

rité; cette mesure empêchera les 

tout petits, les jeunes enfants et 

toute  autre  personne  à  risque 

d’avoir accès à la pièce et aux 

surfaces chaudes.

       WARNING 

B-Vent appliances are 

not designed to operate 

in negatively pressured 

environments (pressure within 

the home is less than pressures 

outside). Significant negatively 

pressured environments caused 

by weather, home design, or 

other devices may impact the 

operation of these appliances. 

Negative pressures may result 

in poor flame appearance, 

sooting, damage to property 

and/or severe personal 

injury. do not operate these 

appliances in negatively 

pressured environments.

TABLE Of CONTENTS 

2

Содержание SLBV-35

Страница 1: ...PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL...

Страница 2: ...on system No external electrical power is required to operate these appliances however 120V AC is recommended see Step 4 Install Field Wiring on Page 12 Use Only These Approved Vent Components These v...

Страница 3: ...localcodesor intheabsenceoflocalcodes with the USA National Electrical Code ANSI NFPA 70 latest edition or in Canada the Canadian Electrical Code CSA C22 1 latest edition Provide adequate clearances a...

Страница 4: ...Table 3 Requirements for the Commonwealth of Massachusetts Thesefireplacesareapprovedforinstallationin the US state of Massachusetts if the following additional requirements are met Install this appli...

Страница 5: ...rom furniture and draperies Figure 3 En raison des temp ratures lev es l appareil devrait tre install dans un endroit o il y a peu de circulation et loin du mobilier et des tentures Figure 3 The locat...

Страница 6: ...a chimney vent servicing a solid fuel fireplace provided the B vent cap is at least 2 ft 0 6 m away from the nearest point of the chimney opening Gas Vent Rule Gas vent caps are not permitted within 8...

Страница 7: ...appliance front face blacksheetmetal Neverallowcombustiblematerialstobepositioned in front of or overlapping the appliance face see Figure 5 also see Figure 30 on Page 23 Non combustible materials su...

Страница 8: ...raming Frame the appliance as illustrated in Figures 8 1 and 8 2 All framing details must allow for a minimum clearance to combustible framing members as shown in Table 6 Page 7 If the appliance is to...

Страница 9: ...Figure 8 1 Framing Dimensions Model No A B C SLBV 35 in 35 1 4 35 1 4 16 mm 895 895 406 SLBV 40 in 40 1 4 40 1 4 16 mm 1022 1022 406 C is the required framing depth dimension when the finish material...

Страница 10: ...VER PLATE with KNOCKOUT Right Side 16 in 406 mm Hood Left Side View 5 7 8 in 149 mm NOTE It is recommended that gas be stubbed in from LEFT side only 3 in 76 mm 9 1 2 in 241 mm GAS INLET KNOCKOUT 7 3...

Страница 11: ...ions Allappliancesarefactory equippedwithaflex ible gas line connector and 1 2 inch shutoff valve See Step 6 on Page 15 Never use galvanized or plastic pipe Gas lines must be routed constructed and ma...

Страница 12: ...through the knockout opening and into the unit junction box 5 Connect the black power supply wire to the lower outlet s red pigtail lead and the white power supply wire to the common terminal of the...

Страница 13: ...tion Instructions TRANSFORMER 3V BROWN BROWN BLACK BATTERY BACK UP BLACK SENSOR BLACK IGNITER IGNITER MODULE 3V RED PILOT IN OUT VENT LO HI TH TP TH TP IN ORANGE THTP BLACK TP GREEN TH HIGH LIMIT SWIT...

Страница 14: ...the lower control compartment opening See Figure 15 To open the outside air shutter open the bottom controlaccesspanel reachintothecontrolcom partment and pull the outside air control lever all the wa...

Страница 15: ...the gas flex line Using pipe dressing materials appropriate for the gas type securely affix the shut off valve to this determined pipe length at a convenient location outside of the appliance lower co...

Страница 16: ...appliances only Note Lighting Instructions are also found on the literature tag tied to the gas piping next to the gas valve To access the tag open the lower control compartment door by pulling the pa...

Страница 17: ...2 Separate the glowing ember material into pieces about the size of a quarter Keep the pieces fluffed up not matted Distribute the pieces over the sur face of the burner as shown in Figures 23 and 24...

Страница 18: ...le at the bottom of log 4 over the nub of log 2 as shown 4 2 SLBV Firebox Accessories Parts Cat No Model No Description H7244 SLBV 35 Log Set Assembly 88L53 FGE Bag of Glowing Embers Rockwool 80L42 FD...

Страница 19: ...ent sooting make sure logs do not cover any burner openings Step 4 Align the hole at the bottom of log 5 over the Nub of log 3 as shown 3 5 Step 2 Align hole at the bottom of left front log 2 over the...

Страница 20: ...ing on both sides is even and equal Control Compartment Panel Hood Glass Door Header Spacing Top Standoffs Flush Nailing Flange 1 2 Nailing Flange 5 8 Nailing Flange Glass Door Spring Latch Control Co...

Страница 21: ...en tally to a more open position until the proper flame appearance is achieved If flame stays lowered blue adjust the air shutter incrementally to a more closed position until the proper flame appeara...

Страница 22: ...ician inspect the fireplace and venting for these conditions and repair as needed To RESET the safety limit switch push the reset button located between the wire terminals on the back of the switch Fo...

Страница 23: ...ished wall position framework to accom modate the thickness of the finished wall Figure 30 For Cold Climate Insulation see Page 5 For Clearances see Page 7 Top of Appliance 1 in 25 mm min Figure 30 Co...

Страница 24: ...sa Nettoyez soigneusement la plaque murale de l interrupteur pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui con...

Страница 25: ...screws b Remove the pressure regulator spring poppet diaphragm and bushing c Discard all removed components d Make sure the rubber gasket in stalled on the back of the replace ment pressure regulator...

Страница 26: ...version label provided in the conversion kit next to the rat ing plate on the appliance Step 13 Turn on gas supply and test for gas leaks refer to Page 16 Always test pressures with the valve regulato...

Страница 27: ...Notes SUPERIOR B VENTGASFIREPLACES MODELS SLBV 35 SLBV 40 INSTALLATION INSTRUCTIONS 27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE...

Страница 28: ...es at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information SUPERIOR B VENT...

Отзывы: