OPTIONAL GAS LINE INSTALLATION
Continued
GLASS DOOR INSTALLATION
Seal Opening
with
Refractory
Cement
Outside of
Fireplace
Gas Line
Conduit
Repack
Insulation
Incoming 1/2"
Black Iron
Pipe
Side
Firebrick
Finished
Side
Provide Enough
Threaded End for
Fitting Connection
Figure 38 - Gas Line Installation
A gas line or gas log lighter may be installed for the purpose of installing
a vented or vent-free decorative gas appliance incorporating an automatic
shutoff device and complying with the Standard for Decorative Gas Ap-
pliances for Installation in Vented Fireplaces, ANSI Z21.60 or American
Gas Association draft requirements for Gas Fired Log Lighters for Wood
Burning Fireplaces, Draft NO. 4 dated August, 1993.
If you install a decorative gas appliance (vented gas log), the deco-
rative gas appliance must comply with the Standard for Decorative
Gas Appliance for Installation in Solid Fuel Burning Fireplaces, ANS
Z21.60 or Z21.84 and shall also be installed in accordance with the
National Fuel Gas Code, ANSI 7223NFPA 54 latest edition.
If you wish to install an unvented (vent-free) gas log set, only unvented
gas log sets which have been found to comply with the standard for
unvented room heaters, ANSI Z21.11.2 are to be installed in this
fireplace.
WARNING: If the fireplace has been used for wood
burning, the firebox and chimney must be cleaned
of soot, creosote and ashes be a qualified chimney
cleaner. Creosote will ignite if heavily heated.
WARNING: When using a decorative vented gas log,
the damper must be removed or permanently locked in
the fully open position and the glass doors must be in
the fully open position.
DOOR FRAME MODELS
BDMO36E/G/C, BDMO42E/G/C AND BDMO50E/G/C
Installation
1. Remove screws from smoke shelf (see Figure 39).
2. Mount top door frame and secure with screws provided (see
Figure 39).
3. Place bottom door frame on top of Hearth Panel Lip at front of
fireplace (see Figure 40).
4. Secure bottom door frame to brick with two hex screws provided
as shown in Figure 40 using a 7/16" open end or adjustable
wrench.
Figure 40 - Installing Bottom Door Frame
Figure 39 - Installing Top Door Frame
Top Door
Frame
Smoke
Shelf
WARNING: Discontinue use of the appliance im-
mediately if doors are damaged and contact a quali-
fied installer for repair. Only doors certified with the
appliance shall be used.
WARNING: Do not slam or strike doors. Damage
can result in a hazardous condition.
Hex Screw
Bottom
Door Frame
Hearth
Panel Lip
Hearth