background image

Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900223-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Superior™ Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against 

thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited 

Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement 

is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevail-

ing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS 

to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 

venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a 

particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Содержание DRT4036TEN

Страница 1: ...CA TOCAR EL VIDRIO WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death AVERTISSEMENT Assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d incindie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Do not store or use ...

Страница 2: ...al applications This fireplace must be installed with INNOVATIVE HEARTH PRODUCTS vent pipe components and terminations This fireplace complies with the National Safety Standards and is listed and tested by PFS Corporation to ANSI Z21 50 CSA 2 22 standard as vented gas fireplace NOTICE Decorative product not for use as a heating appliance This fireplace must be installed by a qualified certified or...

Страница 3: ... on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable material on or near the ap...

Страница 4: ...ilot light before cleaning fireplace 6 Have venting system inspected annually by a qualified service person If needed have venting system cleaned or repaired See Cleaning and Maintenance page 27 7 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fire place nameplate 8 This appliance when installed must be electrically grounded in accorda...

Страница 5: ...orizontal applications This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed Each time you turn on your fireplace you may notice some amount of condensation on the inside of the fireplace glass This is normal and will disappear after 10 20 minutes of operation Your direct vent gas fireplace system fireplace and venting i...

Страница 6: ...ce installations Wall or fram ing material can be placed directly against any exterior surface on back sides or top of your fireplace except where standoff spacers are integrally attached If standoff spacers are attached to your fireplace these spacers can be placed directly against wall or framing material See fram ing details page 7 When locating termination cap it is impor tant to observe the m...

Страница 7: ...tem you may run system s circulat ingblowerwhileusingfireplace This will help circulate the heat throughout the house FRAMING AND FINISHING Figure 5 shows typical framing of this fire place Figure 6 shows framing for corner installation All minimum clearances must be met If you are using a separate combustible man tel piece refer to Figure 7 for proper instal lation height You can install noncombu...

Страница 8: ...0 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clearance above paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under veranda porch deck 12 30 5 cm minimum N clearance above a roof shall exten...

Страница 9: ...e directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the in...

Страница 10: ...ent pipe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burning appliance A direct vent appliance must have its own venting system DO NOT common vent this appliance These models are approved to be vented either horizontally through an outside wall or vertically t...

Страница 11: ... lugs indentations These lugs will slide straight into match ing slots on male ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 9 Note Horizontal runs of vent must be sup ported every three feet Use wall straps for this purpose 3 Assemble desired combination of pipe and elbows to fireplace f...

Страница 12: ...un to vent cap see Figure 13 Carefully move fireplace with vent assembly attached toward wall and insert vent pipe into horizontaltermination Pipeoverlapshouldbe a minimum of 1 1 4 see Figure 14 Slide wall firestop against interior wall surface and attach with screws provided See Figure 14 for horizontal termination details Place fireplace into position and shim with noncombustible material if nee...

Страница 13: ...termination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which could cause a fire Operation of improperly installed and main tained venting system could result in serious injury property damage or loss of life GROUND FLOOR INSTALLATION Recommended Applications Through the wall using round or squa...

Страница 14: ...s air space to combustibles when passing through ceilings walls roofs enclosures attic rafters etc Do not pack air spaces with insulation Also note maximum vertical rise of venting system and any maximum horizontal offset limitations 2 Set fireplace in desired location Drop a plumb line down from ceiling to position of fireplace exit flue Mark center point where vent will penetrate ceiling Drill a...

Страница 15: ... gases 5 Place flashing over pipe section s ex tending through roof Secure base of flashing to roof and framing with roofing nails Be sure roofing material overlaps top edge of flashing as shown in Figure 17 There must be a 1 clearance from vent pipe to combustible materials 6 Continue to add pipe sections until height of vent cap meets the minimum building code requirements described in Figure 8 ...

Страница 16: ... Wall Pipe Galvanized P58 12 12 Section Double Wall Pipe Galvanized P58 24 24 Section Double Wall Pipe Galvanized P58 36 36 Section Double Wall Pipe Galvanized P58 48 48 Section Double Wall Pipe Galvanized PA58 712 Adjustable 7 12 Section Double Wall Pipe Galvanized E58 45 45 Elbow Galvanized E58 90 90 Elbow Galvanized HTS 58 Horizontal Square Termination Galvanized HHT 58 Horizontal High Wind Rou...

Страница 17: ...ameter or greater to allow proper gas volume to fireplace If pipe is too small undue loss of volume will occur Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from fireplace see Figure 22 page 18 IMPORTANT Install main gas valve equip ment shutoff valve in an accessible location The main ...

Страница 18: ...ill prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas We recommend that you install a sediment trap drip leg in supply line as shown in Figure 22 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and fir...

Страница 19: ...tion fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Reconnect fireplace and equipment shutoff valve to gas supply Check recon nected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 24 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas fireplace or openi...

Страница 20: ...of firebox 4 Tilt open glass door 45 from the bottom of firebox and lift up to release door from firebox top retainer see Figure 27 Replacing Glass Door 1 Position door frame in front of firebox opening with bottom of door tilted away from firebox see Figure 27 2 Hook top flange of door frame over top of firebox frame 3 Secure 2 bottom door latches Door Retainer Glass Door Bottom Access Panel Door...

Страница 21: ...hown in Figures 28 28a and 28b Figure 29 Installing Lava Rock Lava Rock Figure 28 Installing Loose Logs Figure 28a Installing Loose Log 1 Figure 28b Installing Loose Logs 2 and 3 Loose Log 3 Loose Log 1 Loose Log 2 Loose Log 2 Loose Log 3 Loose Log 1 Underneath Log 2 Glowing Embers 3 Place lava rock around base of burner Make sure burner ports are not covered see Figure 29 4 Place ember flakes aro...

Страница 22: ...ront of logs as shown in Figure 31 Be sure grate is balanced so it does not fall or lean onto logs Grate does not attach to hearth assembly Figure 30 Installing Ember Flakes Figure 31 Installing Scrap Log Pieces Ember Flakes Scrap Log Pieces REMOVING LOG SET BURNER MODULE Connecting and Disconnecting Gas Line WARNING A qualified ser vice person must connect and disconnect fireplace with gas supply...

Страница 23: ...CAUTION The gas supply shall be shut off prior to discon necting the electrical power if any before proceeding with this installation CAUTION Use gloves when removing the log set burner modulefromyourfirebox Some metal edges may be sharp Use caution with log sets as logs are fragile 1 Remove glass door see page 20 2 Remove grate and all floor media see page 22 3 Carefully lift and remove 3 hearth ...

Страница 24: ...atteries are fully charged and provide continuous out put voltage of at least 5 3 Volts The length of the wire the more battery power is required to deliver signals between the remote receiver and the gas valve Recommended length is no longer than 20 feet The remote control should operate with as little as 9 0 Volts bat tery power FIREPLACE INSTALLATION Continued TROUBLESHOOTING If you encounter p...

Страница 25: ... the OFF position 4 Remove center brick control cover 5 Turn equipment shutoff valve clockwise to the OFF position see Figure 36 Do not force 6 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information If you don t smell gas go to the next step 7 Turn equipment shutoff valve counter clockwise to the ON position Do ...

Страница 26: ... PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame Alterations may have occurred during shipping and handling The pilot is located on right hand side of burner The flame must envelope 1 4 of top of the ignitor sensor and grounding stem If your pilot assembly does not meet these requirements Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to i...

Страница 27: ...early by a qualified service person Fireplace may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc GLASS DOORS WARNING Handle glass door panels with care Do not strike slam or otherwise abuse glass Do not operate fireplace with the glass door unlatched removed cracked or broken WARNING Do not use abrasive cleaners as this may damage glass Use a nonabra...

Страница 28: ... material before cleaning burners and replace when cleaning is complete Burner and controls should be cleaned with compressed air to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dirt or lint LOGS Use a vacuum cleaner to remove any carbon buildup on logs Replace material periodically as needed See Replacement Parts page 39 VENTING SYSTEM Conduct a...

Страница 29: ...see if you have gas supply and that equip ment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after re peated attempts appliance does not light call for quali fied service and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pilot ...

Страница 30: ...r cor roded 1 Check electrical connec tions 1 Clean and adjust pilot flame for maximum flame im pingement on thermopile 2 Have vent system inspect ed including termination cap Remove any restriction or obstruction 1 This is normal with most fireplaces If noise is ex cessive contact qualified service person 1 Problem will stop after a few hours of operation TROUBLESHOOTING Continued POSSIBLE CAUSE ...

Страница 31: ... holes blocked 3 Improper venting or exces sive blockage 4 Excessive amounts of em bers and pan material OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combustion Glass soots Dark residue on logs or inside of fireplace REMEDY 1 Locate and correct all leaks see Checking Gas Con nections page 19 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2...

Страница 32: ...Fireplaces US com 126721 01A 32 PARTS MODELS DRT4036TEN DRT4036TEP DRT4042TEN AND DRT4042TEP 1 2 3 8 32 32 33 36 32 42 8 9 10 11 17 22 25 26 27 7 4 5 12 16 18 19 20 29 31 30 23 24 28 21 13 14 15 38 3 6 34 35 36 37 ...

Страница 33: ... 42 NG High Altitude 1 7 123210 01 Grate 36 1 123210 02 Grate 42 1 8 122652 01 Door Latch 2 9 Firebox Leg 4 10 Firebox Bottom 1 11 121431 01 Gasket 36 1 111913 02 Gasket 42 1 12 122919 01 Draft Diverter 1 13 Air Exchange 1 14 5 Gasket 1 15 5 Inner Connector 1 16 A E Insulation 1 17 Firebox Surround 1 18 Firebox Top 1 19 Relief Assembly 2 20 Relief Bracket 4 21 Top Plenum 1 22 Rear Plenum 1 23 5 Ga...

Страница 34: ...www SuperiorFireplaces US com 126721 01A 34 PARTS BURNER ASSEMBLY MODELS DRT4036TEN DRT4036TEP DRT4042TEN AND DRT4042TEP 8 15 1 2 3 4 5 7 24 6 9 4 5 10 16 14 12 13 17 25 13 11 18 19 22 23 20 21 ...

Страница 35: ...be Dormont 3 8 Dia x 11 1 15 111817 09 Flextube Dormont 3 8 Dia x 24 1 16 Pilot Bracket 1 17 122116 01 Dexen Valve NG 1 122117 01 Dexen Valve LP 1 123782 01 Dexen Valve NG High Altitude 3 8 1 18 112823 01 Brass T Fitting 3 8 1 19 122118 01 Control Module 1 20 122119 01 Battery Relay 1 21 122121 01 Battery Pack 1 22 122860 01 Valve Bracket 1 23 125243 01 Remote Control Kit 1 24 Log Assembly 36 1 Lo...

Страница 36: ...www SuperiorFireplaces US com 126721 01A 36 PARTS REFRACTORY PARTS 1 2 4 5 6 3 Herringbone Brick Shown ...

Страница 37: ...fractory Stacked 36 White 1 125089 02 Left Refractory Stacked 36 Red 1 3 125128 01 Right Refractory Herringbone 42 White 1 125128 02 Right Refractory Herringbone 42 Red 1 125092 01 Right Refractory Herringbone 36 White 1 125092 02 Right Refractory Herringbone 36 Red 1 125127 01 Right Refractory Stacked 42 White 1 125127 02 Right Refractory Stacked 42 Red 1 125091 01 Right Refractory Stacked 36 Whi...

Страница 38: ... Orifice 44 DRT4036TEP Rating 31 000 Btu hr Gas Type Propane LP Gas Only Ignition Electronic Manifold Pressure 10 w c Minimum Inlet Supply Pressure 11 w c Maximum Inlet Supply Pressure 13 w c Front Orifice 56 Rear Orifice 56 DRT4042TEP Rating 37 000 Btu hr Gas Type Propane LP Gas Only Ignition Electronic Manifold Pressure 10 0 w c Minimum Inlet Supply Pressure 11 w c Maximum Inlet Supply Pressure ...

Страница 39: ...Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat propane LP gas supply might be low pro pane LP units only You may feel your gas pressure is too low If so contact your local gas supplier ACCESSORIES Purchase these accessories from your local dealer If they can not supply these accessories call INNOVATIVE HEARTH PRODUCTS at...

Страница 40: ...ral or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installation or ...

Страница 41: ...HIS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________________________ Keep receipt for warranty verification ...

Страница 42: ...NOTES ...

Страница 43: ...www SuperiorFireplaces US com 126721 01A 43 NOTES ...

Страница 44: ...126721 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126721 01 ...

Отзывы: