www.SuperiorFireplaces.US.com
126721-01A
29
TROUBLESHOOTING
WARNING: Turn off fireplace and let cool before servicing. Only
a qualified service person should service and repair fireplace.
CAUTION: Never use a wire, needle or similar object to clean
pilot. This can damage pilot unit.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. No gas supply or shutoff
valve is OFF
2. Air in gas line
3. Construction debris clog
-
ging pilot orifice
4. Low gas pressure
5. Kinked pilot line
6. Control valve is not opening
7. No power to unit or ignition
module or power trans
-
former is bad
REMEDY
1. Check to see if you have
gas supply and that equip
-
ment shutoff valve is
opened
2. Repeat lighting procedure
several times to purge all
air out of lines. If after re
-
peated attempts appliance
does not light, call for quali
-
fied service and repair
3. Remove debris and dirt,
inspect and clean any other
possible obstructions
4. Contact your gas supplier
to check pressure
5. Have a qualified technician
replace pilot line
6. Replace control valve (Re
-
fer to
Replacement Parts
,
page 39)
7. Check that main power is
on and that all wire connec
-
tions are made correctly to
ignition model (see
Wiring
Diagram
, page 38). Check
for 24 VAC at the second
-
ary side of transformer. If 24
VAC is present and module
does not operate, have
module replaced. Other
-
wise have transformer re
-
placed
OBSERVED PROBLEM
Ignitor will not spark or pilot
will not light
Содержание DRT4036TEN