Superior DRI3030TENC Скачать руководство пользователя страница 34

34

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SAFETY / LISTING LABEL - DRI3030TENC

 

DRI3030TENC

MANUFACTURED BY:

INNOVATIVE HEARTH PRODUCTS

1502 14TH ST NW

AUBURN, WA., USA 98001

SERIAL

 NO.

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL

CONFORMS TO ANSI Z21.88-2014/CSA 2.33-2014 AND CAN/CGA-2.17-M91 (R2009).

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY.  IF NOT, FOLLOW THE CURRENT ANSI Z223.1/NFPA 

54-LATEST EDITION (USA) OR CAN/CGA  B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE 

WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES ONLY - MASONRY 

OR FACTORY BUILT.  THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS. 

THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN 

AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED HOME (USA ONLY) OR MOBILE HOME, WHERE NOT PROHIBITED BY LOCAL 

CODES. SEE OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A 

CERTIFIED KIT IS USED.
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, 

FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22.1-LATEST EDITION (CANADA).

FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.

RATINGS

DRI3030TENC

For use only with barrier Part 

No. J7510. Follow installation 

instructions.

NATURAL GAS

LP GAS

MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*

32,000/21,000

27,000/21,000

MANIFOLD PRESSURE (IN. WC)

3.5

10.0

MIN. INLET PRESSURE (IN. WC)

5.0

10.5

ORIFICE (DMS) 0-2,000 FT (0-610 M)*

#36

#53

*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M. ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS

CHIMNEY - USE 3" (76 MM) GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635.  

THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER’S 

INSTALLATION INSTRUCTIONS.

FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 1,000 FT (305 M).

CAUTION:

 HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP 

CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY. 

KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS 

ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY. DO NOT 

OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S) 

SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE 

INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS 

APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE 

AGENCY OR THE GAS SUPPLIER.

DO NOT REMOVE OR COVER THIS LABEL

Part No. 900375-00  Rev. 0, 12/2014

IGN ______

DATE OF MANUFACTURE / DATE DE FABRICATION

2014

2016

2017

2015

JAN

FEB MAR

APR MAY

JUN

JUL

AUG SEP

OCT

NOV DEC

MODEL

MINIMUM CLEARANCES

Note: Hearth protection to be min. 

3/8” (10mm) thick non-combustible 

or equivalent, with a k factor of .84.

A

D

B

E

C

CL

MANTEL

TRIM

MINIMUM FIREPLACE SIZES REQUIRED

 ....................

  DRI3030TENC

Front Opening ...................................................................  31.50” (800mm)

Height .................................................................................  19.50” (495mm)

Rear Width  ........................................................................  18.00” (457mm)

Depth  .................................................................................  16.00” (406mm)
MINIMUM CLEARANCES TO COMBUSTIBLES

  A = Top Facing to Bottom of Appliance .....................  31.5" (800mm)

  B = Side Facing or Side Wall to Center of Glass ......  25.5" (648mm)

* C = 10.5” (267mm) Mantel  to Bottom of Appliance .  39" (991mm)
HEARTH PROTECTION

  D = Vertical Distance from base of appliance            0"              2”              4”

   to  Hearth Extension ..........................................     (0mm)      (51mm)   (102mm)  
  E = Minimum Horizontal Distance 

         13"           10”             0”

   from Front of Appliance ..................................        (330mm)  (254mm)    (0mm)

MANTEL

FACING

*See owner’s manual for additional mantel clearances and options.

Report No. 14-192

C

US

Содержание DRI3030TENC

Страница 1: ...cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure...

Страница 2: ...ADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre...

Страница 3: ...o Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamable...

Страница 4: ...eplace Dimensions 13 Clearances to Combustibles 14 Insert Leveling 14 Fan Control Module Switch 15 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Pleas...

Страница 5: ...avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cett...

Страница 6: ...rcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor de control en el panel de control del artefacto verifique que el interruptor opera el artefacto encendi...

Страница 7: ...eil Figure A Choisissezlalanguequiestprincipalementparl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer...

Страница 8: ...eart or lung disease or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the...

Страница 9: ...ver use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first t...

Страница 10: ...ral gas or propane Is NOT for use with solid fuels Is approved for sitting rooms and or bedrooms This appliance is suitable for installation into masonry or factory built fireplaces Fireplace Requirem...

Страница 11: ...a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CSA...

Страница 12: ...sion kit see Page 33 for ordering information This appliance comes from the factory equipped to burn natural gas at a specified elevation Only IHP conversion kits can be used to convert from NG to LP...

Страница 13: ...A 31 1 2 800mm Front Opening Width B 19 1 2 495mm Height C 18 457mm Rear Width D 16 406mm Fireplace Depth Top View Left Side View Right Side View Front View A B C D Figure 3 Minimum Fireplace Cavity...

Страница 14: ...ve the leg to the desired height and then tighten the screws Repeat these steps for each adjusting leg Facing and Mantel Clearances See Figure 4 CLEARANCES TO COMBUSTIBLES DRI3030TENC Facing and Mante...

Страница 15: ...The vent should terminatewithalisteddirect ventterminationcap Thechimneyshouldbe sealed around the cap to prevent air and rain from entering the chimney Adhere to the vent manufacturer s instructions...

Страница 16: ...e sealed around the vent pipes Use a non combustible seal off plate i e 22 gage sheet steel or unfaced fiberglass insulation 8 lb per square foot density minimum to seal around the vent pipes Whicheve...

Страница 17: ...moyen d isolant incombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supplied with the gas fireplace insert to the inside of the firebox of the firepla...

Страница 18: ...rackets from the firebox using a 5 32 allen wrench seeFigure11 Retainthescrewsforstep4 anddiscardthebrackets as they will not be needed 3 Install the rear liner panel by inserting the tabs on the bott...

Страница 19: ...ound panels so the edge of the surround panel fits just behind the rounded edge of the trim 8 Install three spring clips found in parts bag in firebox in each piece of trim by inserting them between t...

Страница 20: ...d check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary If the pressure is not suffici...

Страница 21: ...or firebox panels If soot begins to form after burning the air shutter should be opened gradually until the sooting condition stops Gas quality and gas pressure may vary which can affect the burning c...

Страница 22: ...e and is properly sealed Operating Instructions See Page 36 for operating instructions IMPORTANTNOTE Whenopeningthelowerdoorontheface while the insert is burning pull at the far left or far right vent...

Страница 23: ...e that it is ready to synchronize with the Remote transmitter Install 3 AAA type batteries in the Remote transmitter battery bay located on the base of the Remote With the batteries already installed...

Страница 24: ...e flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the h...

Страница 25: ...a yellow orange color Adjusting the appliance to cause the flames to turn orange sooner may result in poor combustion sooting and a hazardous situation See Figure 26 showing proper flame appearance W...

Страница 26: ...TURE N C NORMALLY CLOSED N O NORMALLY OPEN FEMALE DISCONNECT MALE DISCONNECT STUD CONNECTION REMOTE RECEIVER PILOT ON AUTO SWITCH FAN CONTROL MODULE POWER ADAPTOR BOX 6 WHT 5 BLUE 11 YLW 10 ORG 13 BLK...

Страница 27: ...flow of ventilation air or use vents other than those approved for use with this appliance o Check that the chimney and its outlet are open and free of soot block age or debris The venting system sho...

Страница 28: ...Code Part 1 CSA C22 1 latest edition See Operating Options for burner ON OFF switch information Glass Door Cleaning and Maintenance Cleaning Do not remove or clean the glass door when hot When cool t...

Страница 29: ...and lifting up slightly and then out away from the unit 3 Lay the facade face down on a soft surface that will not scratch the paint 4 Using a 3 8 socket remove the six nuts holding the left 1 and rig...

Страница 30: ...reaching the appliance Loose wires to the valve or ignition module Pilot flame is not engulf ing the sensor Obstructed vent system Check the gas supply and gas shutoff valves Checkcontrolcompartmentfo...

Страница 31: ...n Burner 36 NG 32 000 BTU 29 H5964 Orifice Main Burner 53 LP 27 000 BTU 31 H8491 Pilot Assembly Convertible NG or LP 32 H8509 Gas Control Valve Auto Hi Lo Regulator NG if LP also requires H8858 LP Reg...

Страница 32: ...E DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 38 Facade REPLACEMENT PARTS DRI3030TENC 14 36 25 33 34 21 22 23 13 31 29 32 1 10 9 17 8 16 7 6 15 5 4 37 2 26 27 11 31 29 32 1 10 9 8 17 2 11 27 26 4 5 36 15...

Страница 33: ...Reflective Black Porcelain Panel Kit required accessory Cat No Model Description H8855 RDV BLK PCLPNL Black Porcelain Panels Black Porcelain Surround Trim Kits Cat No Model Description H5143 GFT2941...

Страница 34: ...RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE...

Страница 35: ...e appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch...

Страница 36: ...36 NOTES...

Страница 37: ...or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damage...

Страница 38: ...e recommend that you record the following important information about your appliance Please contact your IHP dealer for any questions or concerns REPLACEMENT PARTS See Page 31 for a complete replaceme...

Отзывы: