Superior DRI3030TENC Скачать руководство пользователя страница 23

23

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

AUTO

ON

PILOT

BURNER

TOTAL
COMFO

RT 

CONTR

OL

OPERATION

Remote Control System

The Remote and Receiver allows you to command the functions of your 

appliance from the comfort of your chair and is configured to control 

the On/Off primary burner operation, its flame levels (through six levels) 

and provides On/Off and Smart thermostatic control of the appliance.

The system controls blower speed through six (6) levels and has a 

constantly powered 120V/60Hz power outlet.

The Receiver connects directly to the gas valve, stepper motor and the 

Blower Control Module with and umbilical cord wiring harness 

(see Wire 

Diagram on 

Page 26

)

.  

The Receiver accepts commands via radio frequency from the Remote 

(transmitter) and does not require line-of-sight operation.  

The Receiver three position slider switch can be set to one of three posi-

tions:  ON (Manual Override), REMOTE (Remote Control) or OFF.

Initializing The System For The First Time

Install 4 AA batteries into the receiver battery bay (behind the switch 

plate).  Note the polarity of the battery and insert into the battery bay as 

indicated on the Battery cover (+/-).

Place the 3 position slider switch in the "Remote" position 

(see 

Figure 

21

)

.  Using the end of a paper clip, or other similar object, insert the 

end of the paper clip into the hole marked "PRG" on the Receiver front 

cover.  The Receiver will "beep" three (3) times to indicate that it is ready 

to synchronize with the Remote (transmitter). 

Install 3 AAA type batteries in the Remote (transmitter) battery bay, 

located on the base of the Remote.  With the batteries already installed 

in the Remote, push the ON button.  The Receiver will “beep” four times 

to indicate the Remote’s command is accepted and sets to the particular 

code of that Remote.  The  system is now initialized.

Low Battery Power Detection

The life span of the Receiver batteries depends on various factors:  quality 

of the batteries used, the number of ignitions of the appliance, the number 

of changes to the room thermostat set point, etc.

When the Receiver batteries are low, two “beeps” will be emitted from 

the Receiver when it receives an ON/OFF command from the Remote. 

This is an alert for a low battery condition for the Receiver.  When the 

batteries are replaced the “beep” will be emitted from the Receiver when 

the ON/OFF key is pressed (See Initializing The System).

Figure 21 - Control Compartment

ON REMOTE OFF

PRG

       WARNING 

Fire hazard.  Can cause severe injury or death.  

The receiver causes ignition of the appliance.  The 

appliance can turn on suddenly.  Keep away from 

the appliance burner when operating the remote 

system or activating manual bypass of the remote 

system.

       CAUTION 

Property damage hazard.  Excessive heat can cause 

property damage.  The appliance can stay lit for many 

hours.  Turn off the appliance if it is not going to be 

attended for any length of time.  Always place the 

Transmitter where children can not reach it.

Figure 22 - Remote (transmitter)

Receiver

ON / AUTO

Pilot

ON/OFF Key

THERMOSTAT Key

UP/DOWN Arrow Key

MODE Key

Blue LCD Display

Содержание DRI3030TENC

Страница 1: ...cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure...

Страница 2: ...ADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre...

Страница 3: ...o Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quidos inflamable...

Страница 4: ...eplace Dimensions 13 Clearances to Combustibles 14 Insert Leveling 14 Fan Control Module Switch 15 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Pleas...

Страница 5: ...avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cett...

Страница 6: ...rcionadas con estas instrucciones y prosiga de la siguiente manera 1 Identifique el interruptor de control en el panel de control del artefacto verifique que el interruptor opera el artefacto encendi...

Страница 7: ...eil Figure A Choisissezlalanguequiestprincipalementparl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer...

Страница 8: ...eart or lung disease or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the...

Страница 9: ...ver use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first t...

Страница 10: ...ral gas or propane Is NOT for use with solid fuels Is approved for sitting rooms and or bedrooms This appliance is suitable for installation into masonry or factory built fireplaces Fireplace Requirem...

Страница 11: ...a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CSA...

Страница 12: ...sion kit see Page 33 for ordering information This appliance comes from the factory equipped to burn natural gas at a specified elevation Only IHP conversion kits can be used to convert from NG to LP...

Страница 13: ...A 31 1 2 800mm Front Opening Width B 19 1 2 495mm Height C 18 457mm Rear Width D 16 406mm Fireplace Depth Top View Left Side View Right Side View Front View A B C D Figure 3 Minimum Fireplace Cavity...

Страница 14: ...ve the leg to the desired height and then tighten the screws Repeat these steps for each adjusting leg Facing and Mantel Clearances See Figure 4 CLEARANCES TO COMBUSTIBLES DRI3030TENC Facing and Mante...

Страница 15: ...The vent should terminatewithalisteddirect ventterminationcap Thechimneyshouldbe sealed around the cap to prevent air and rain from entering the chimney Adhere to the vent manufacturer s instructions...

Страница 16: ...e sealed around the vent pipes Use a non combustible seal off plate i e 22 gage sheet steel or unfaced fiberglass insulation 8 lb per square foot density minimum to seal around the vent pipes Whicheve...

Страница 17: ...moyen d isolant incombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supplied with the gas fireplace insert to the inside of the firebox of the firepla...

Страница 18: ...rackets from the firebox using a 5 32 allen wrench seeFigure11 Retainthescrewsforstep4 anddiscardthebrackets as they will not be needed 3 Install the rear liner panel by inserting the tabs on the bott...

Страница 19: ...ound panels so the edge of the surround panel fits just behind the rounded edge of the trim 8 Install three spring clips found in parts bag in firebox in each piece of trim by inserting them between t...

Страница 20: ...d check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary If the pressure is not suffici...

Страница 21: ...or firebox panels If soot begins to form after burning the air shutter should be opened gradually until the sooting condition stops Gas quality and gas pressure may vary which can affect the burning c...

Страница 22: ...e and is properly sealed Operating Instructions See Page 36 for operating instructions IMPORTANTNOTE Whenopeningthelowerdoorontheface while the insert is burning pull at the far left or far right vent...

Страница 23: ...e that it is ready to synchronize with the Remote transmitter Install 3 AAA type batteries in the Remote transmitter battery bay located on the base of the Remote With the batteries already installed...

Страница 24: ...e flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the h...

Страница 25: ...a yellow orange color Adjusting the appliance to cause the flames to turn orange sooner may result in poor combustion sooting and a hazardous situation See Figure 26 showing proper flame appearance W...

Страница 26: ...TURE N C NORMALLY CLOSED N O NORMALLY OPEN FEMALE DISCONNECT MALE DISCONNECT STUD CONNECTION REMOTE RECEIVER PILOT ON AUTO SWITCH FAN CONTROL MODULE POWER ADAPTOR BOX 6 WHT 5 BLUE 11 YLW 10 ORG 13 BLK...

Страница 27: ...flow of ventilation air or use vents other than those approved for use with this appliance o Check that the chimney and its outlet are open and free of soot block age or debris The venting system sho...

Страница 28: ...Code Part 1 CSA C22 1 latest edition See Operating Options for burner ON OFF switch information Glass Door Cleaning and Maintenance Cleaning Do not remove or clean the glass door when hot When cool t...

Страница 29: ...and lifting up slightly and then out away from the unit 3 Lay the facade face down on a soft surface that will not scratch the paint 4 Using a 3 8 socket remove the six nuts holding the left 1 and rig...

Страница 30: ...reaching the appliance Loose wires to the valve or ignition module Pilot flame is not engulf ing the sensor Obstructed vent system Check the gas supply and gas shutoff valves Checkcontrolcompartmentfo...

Страница 31: ...n Burner 36 NG 32 000 BTU 29 H5964 Orifice Main Burner 53 LP 27 000 BTU 31 H8491 Pilot Assembly Convertible NG or LP 32 H8509 Gas Control Valve Auto Hi Lo Regulator NG if LP also requires H8858 LP Reg...

Страница 32: ...E DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 38 Facade REPLACEMENT PARTS DRI3030TENC 14 36 25 33 34 21 22 23 13 31 29 32 1 10 9 17 8 16 7 6 15 5 4 37 2 26 27 11 31 29 32 1 10 9 8 17 2 11 27 26 4 5 36 15...

Страница 33: ...Reflective Black Porcelain Panel Kit required accessory Cat No Model Description H8855 RDV BLK PCLPNL Black Porcelain Panels Black Porcelain Surround Trim Kits Cat No Model Description H5143 GFT2941...

Страница 34: ...RATING 120 VAC 60 HZ LESS THAN 2 AMPS CHIMNEY USE 3 76 MM GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635 THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE...

Страница 35: ...e appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch...