Superior Fireplaces WXS2016 Скачать руководство пользователя страница 21

21

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

DOOR GASKET:  

Periodically check gasket to make sure it is not over-

compressed. If compressed, replace with a special woven door rope. 

(Don’t try substituting rope, only use IHP door rope).

BAFFLE BOARDS: 

Your baffle boards should be inspected during ev-

ery chimney cleaning.  If either board is damaged then replace baffle 

boards. 

DISPOSAL OF ASHES

Whenever ashes get 3 to 4 inches deep in your firebox, and when the 

fire has burned down and cooled, remove excess ashes. Leave an ash 

bed approximately 1 inch deep on the firebox bottom to help maintain 

a hot charcoal bed.

Ashes should be scooped out of a cool stove or fireplace insert with a 

small metal shovel. Ashes should be placed in a steel container with a 

tight fitting lid and moved outdoors immediately. Other waste shall not 

be placed in this container. The closed container of ashes should be 

placed on a non-combustible floor or on the ground, well away from all 

combustible materials, pending final disposal. If the ashes are disposed 

of by burial in soil or otherwise locally dispersed, they should be retained 

in the closed container until all the cinders have thoroughly cooled. Ashes 

can ignite up to 72 hours after removal from the appliance.

Establish a routine for the fuel, wood burner and firing technique. 

Check daily for creosote build-up until experience shows how often 

you need to clean to be safe. Be aware that the hotter the fire the 

less creosote is deposited, and weekly cleaning may be necessary 

in mild weather even though monthly cleaning may be enough in 

the coldest months. Contact your local municipal or provincial fire 

authority for information on how to handle a chimney fire. Have a 

clearly understood plan to handle a chimney fire.

THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR 

PROPER OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO 

OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH 

OPERATING INSTRUCTIONS IN THIS MANUAL.

DOOR HINGES: 

 If door hinges need lubricating, use an anti-seize com-

pound (never use oil) available from your IHP dealer.

DOOR LATCH:

  Adjustment Instructions - 

1. Using a 5/32” hex wrench, remove the side heat shield by removing 3 

screws on the back, 2 screws on the bottom, and 1 screw at the top-

front corner.

2. With the door open, loosen the latch nuts using a 3/8” wrench.  Slide 

the latch assembly forward to loosen the door and backward to tighten 

the door.  

3. Secure the nuts in place and test the door.  If more adjustment is 

required, repeat step 2.

4. Replace the heat shield before burning the stove.
The hinge side of the door can also be adjusted if necessary.  Repeat the 

procedure above on the hinge side of the stove.

Figure 27

       WARNING 

Inspect and clean chimney and connector frequently. 

Under certain conditions of use, creosote buildup 

may occur rapidly. 

CREOSOTE FORMATION AND NEED FOR REMOVAL

When wood is burned slowly, it produces tar and other organic vapors, 

which combine with expelled moisture to form creosote. The creosote 

vapors condense in the relatively cool chimney flue of a slow-burning 

fire. As a result, creosote residue accumulates on the flue lining. When 

ignited, this creosote makes an extremely hot fire. 
The chimney and chimney connector should be inspected at least once 

monthly during the heating season to determine if a creosote buildup has 

occurred. If creosote has accumulated (1/8” [3 mm] or more), it should 

be removed to reduce the risk of a chimney fire.

Have your product inspected at least once a year by a qualified 

service technician to ensure gaskets, air tubes, baffles, and 

venting are in good repair to ensure proper performance. Have 

degraded items replaced by a qualified service technician.

MAINTENANCE

Содержание WXS2016

Страница 1: ...aire la demande Num ro de la pi ce 900917 01 This appliance must be properly installed and operated in order to prevent the pos sibility of a house fire Please read this entire installation and operat...

Страница 2: ...ation 3 Testing Information 4 Draft Requirements 4 Selecting the Proper Venting System 4 Negative Pressure Warning 5 Clearances to Combustibles 6 7 Floor Protection 6 Chimney and Connector 6 Component...

Страница 3: ...h your local building department for requirements in your area 13 Inspectyourchimneyatleastonceamonthduringtheburn ing season to check for soot and creosote accumulations Any accumulations over 1 8 th...

Страница 4: ...cleaning Overfiring of a stove is a condition where excessive temperatures are reached beyond the design capabilities of the appliance The damage that occurs from overfiring is not covered under the m...

Страница 5: ...d by many common household appliances which exhaust air from the home such as a furnace heat pump air conditioner clothes dryer exhaust fans fireplaces and other fuel burning appliances Also the combu...

Страница 6: ...ed for mobile homes but connector pipe may be double wall single wall or single wall with shield as listed above This appliance may be vented into a code approved masonry chimney with flue liner WARNI...

Страница 7: ...19 1 2 9 5 8 8 6 15 37 5 8 46 3 4 34 7 8 16 0 84 57 1 2 305 232 495 245 200 152 381 956 1188 886 406 0 2134 1461 CANADA inches millimeters PIPE INSTALLATION A 3 B 1 C 3 D 1 E 8 F 1 G 3 H 2 I 6 J 2 K 7...

Страница 8: ...ions only 1 4 Diagrams illustrations and photographs are not to scale consult installa tion instructions Product designs materials dimensions specifications colors and prices are subject to change or...

Страница 9: ...all metal chimney at least 6 in diameter or to a masonry chimney with a flue passage of at least 48 square inches It is required that a chimney connector pipe not extend further than the inner wall of...

Страница 10: ...______________________________________ ______________________________________________________ ______________________________________________________ ___________________________________________________...

Страница 11: ...n shall be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from con nector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and...

Страница 12: ...register must not be installed more than ten 10 feet 3050 mm above the base of the stove c The fresh air must come from outside the house The air intake must not draw air from the attic from the base...

Страница 13: ...ll install the baffle blanket It will be installed with the 11 dimension from the front to rear of the firebox Install by lifting it into place between the front and rear baffle Place the blanket over...

Страница 14: ...5 F 10 F 9 F 8 A 4 F 6 D 1 F 2 F 3 D 7 F 11F 12A 13F 14F 15G 16E Figure 15 Side Cut A Way View of Firebox Baffle Blanket Front Baffle Board Rear Baffle Board Firebox Brick Baffle Insulation Parts Figu...

Страница 15: ...able from all IHP dealers Opening Door Lift handle and pull to open door Closing Door Hold handle lifted swing door closed then push handle down to engage latch Handle Door OPERATING HINTS 1 Burn only...

Страница 16: ...ing appliance it is important to become familiar with how the damper control affects heat output and the overall temperature of the appliance A stove thermom eter can be a helpful tool to help ensure...

Страница 17: ...chieve heat output rates that exceed heater design specifica tions can result in permanent damage to the heater Figure 22 Figure 23 OK 4 4 8 Standard Cord of Wood What does Well Seasoned mean When a t...

Страница 18: ...need to have sufficient temperatures inside the firebox for thorough combustion The best method for determining if you have sufficient temperatures is to watch the brick lining in your firebox When yo...

Страница 19: ...he stove is burned with the blower opening unobstructed Figure 24 The optional blower is controlled by a Dial a Temp see Figure 24 It contains an On Off line switch with variable speed control from lo...

Страница 20: ...on ing are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Some people are more affected by carbon monoxide than others including pregnan...

Страница 21: ...a chimney fire THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUC...

Страница 22: ...ior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasivecleaners Donotcleanwithanymaterials which may scratch or otherwise damage the glass Scratches on...

Страница 23: ...2 3 See Poor Draft section above and Cleaning Glass on Pages 4 and 22 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN 2 Check the...

Страница 24: ...Draft Rod Knob 9 F4088 Ash Lip Kit includes hardware 1 4 5 11 6 3 12 13 14 15 16 16 16 16 17 16 21 19 20 16 17 16 19 16 16 17 18 16 22 7 10 9 8 2 Item Cat Description 10 F4101 Pedestal Assembly 11 H5...

Страница 25: ...ND UZI UZI Outside Air Ducting Kit includes 4 insulated flex x 10 long AND F4062 OUTAIRKIT ES Outside Air Panel and Air Channel Kit includes rear pedestal panel and side and front air channels MISC H8...

Страница 26: ...anufactured By INNOVATIVE HEARTH PRODUCTS 1502 14th St NW Auburn WA 98001 USA PREVENT HOUSE FIRES Installanduseonlyinaccordancewithmanufac turer sinstallationandoperatinginstructionsand your local bui...

Страница 27: ...cessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves and inserts are approved for burning dry seasoned wood only c damages caused by failing to pr...

Страница 28: ...give the following information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date...

Отзывы: