background image

32" x 28", 36" x 28", & 42" x 28" Universal Vent-Free Fireboxes

P/N 900975-00  REV. A  06/2019

MODELS

UNIVERSAL VENT-FREE FIREBOX

Due to high temperatures, the appliance should be located out 

of traffic and away from furniture or draperies.
Do not place clothing or other materials on or near this appliance.
IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS 

COMPLETELY BEFORE INSTALLING YOUR VENT-FREE ROOM 

HEATERS.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

FOR YOUR SAFETY:  Do not store or use gasoline 

or other flammables or liquids in the vicinity of 

this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
•  DO NOT light any appliance.

•  DO NOT touch any electrical switches.

•  Do not use any phone in your building.

•  Immediately call your gas supplier from a

    neighbor’s phone. Follow your gas suppliers 

 instructions.

•  If your gas supplier cannot be reached, call

  the fire department.
Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

INSTALLATION AND 

OPERATION INSTRUCTIONS

VRT3232WS      VRT3236WS      VRT3242WS

VRT3232WH      VRT3236WH      VRT3242WH

WARNING: If the information in this manual is 

not followed exactly, a fire or explosion may 

result causing property damage, personal injury 

or loss of life.

FOR USE ONLY WITH A LISTED GAS-FIRED 

UNVENTED DECORATIVE ROOM HEATER NOT TO 

EXCEED 40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.

WARNING: IMPROPER INSTALLATION, ADJUST-

MENT, ALTERATION, SERVICE OR MAINTENANCE 

CAN CAUSE INJURY OR PROPERTY DAMAGE. 

REFER TO THIS MANUAL. FOR ASSISTANCE OR 

ADDITIONAL INFORMATION CONSULT A QUALI-

FIED INSTALLER, SERVICE AGENCY OR THE GAS 

SUPPLIER.

Carefully review the instructions supplied with 

the decorative type unvented room heater for the 

minimum fireplace size requirement.  
DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX 

UNLESS THIS FIREBOX MEETS THE MINIMUM 

DIMENSIONS   REQUIRED FOR THE INSTALLATIONS.

THIS IS A VENT-FREE GAS-FIRED HEATER ENCLO-

SURE.  IT USES AIR (OXYGEN) FROM THE ROOM 

IN WHICH IT IS INSTALLED. PROVISIONS FOR 

ADEQUATE COMBUSTION AND VENTILATION AIR 

MUST BE PROVIDED.  REFER TO COMBUSTION 

AND VENTILATION AIR SECTION, PAGE 4.

In the Commonwealth of Massachusetts:

  Installation must be performed by a licensed plumber or 

gas fitter;

•  See Table of Contents for location of additional Common-

wealth of Massachusetts requirements.

C

US

Report No. F14-168

P900975-00

Содержание VRT3232WH

Страница 1: ...236WS VRT3242WS VRT3232WH VRT3236WH VRT3242WH WARNING If the information in this manual is not followed exactly a fire or explosion may resultcausingpropertydamage personalinjury or loss of life FOR U...

Страница 2: ...lified service person The heater should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet ing bedd...

Страница 3: ...ON Packaging List Vent Free Gas Firebox Hood Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2approvedDecorative TypeVent F...

Страница 4: ...s a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose...

Страница 5: ...heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Not to Scale Figure 1 CAUTION Do not install in the vicinity where gasoline or other flammable liq uids may be stored...

Страница 6: ...ge we recommend the use of high temperature paint rated 175 F or higher on the underside of the mantel Clearances Ensure the minimum clearances shown in Figures 2 through 4 are maintained Left and rig...

Страница 7: ...rectlyonacombustiblesurface The appliance should be mounted on a fully supported base extending the full width and depth of the unit The appliance may be located on or near conventional construction m...

Страница 8: ...aming or into prepared framing Step2 Plumbgasline Gasconnectionsshould onlybeperformedbyanexperienced licensed certified tradesman Step 3 Install decorative type Vent Free room heater per the instruct...

Страница 9: ...l covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the firebox by checking...

Страница 10: ...RT3242WH 42 1067 27 7 8 708 47 3 4 1213 37 1 4 947 29 1 2 749 20 508 3 77 3 3 16 81 15 7 8 404 7 1 2 191 12 305 1 3 8 35 5 1 2 140 30 3 8 772 29 5 8 753 Top View E F A C Front View Right Side View 2 3...

Страница 11: ...4 Table 1 This Table corresponds to Figures 7 8 and 9 A C D H F G E Rough Framing Face Unfinished Shown Back Wall Of Chase Enclosure Including Finishing Materials If Any Back Wall Of Chase Enclosure I...

Страница 12: ...rebox for safe operation for model VRT3232 series in all installations this part is optional for VRT3236 and VRT3242 models See Figure 11 These hood kits are design to be fitted to the face of the app...

Страница 13: ...fminorscratchesanddiscolorationoftheapplianceblackpaintedsurfaces may be accomplished with the touch up paint kit PA I N T APPROVED ACCESSORIES AND COMPONENTS Outside Air Gate Duct Kit Cat No ModelNo...

Страница 14: ...3 4 5 2 1 6 3 4 5 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or perso...

Страница 15: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 16: ...rth Products IHP reserves the right to make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distrib...

Отзывы: