NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.

6

40"

16"

Optional

Hearth 

Extension

Fireplace 

Opening 

Top Stand- 

Off Spacer 

(on appliance) 

Top of Appliance 

Finished Wall 

 

Header 

Non-Combustible 

Material 3" Min. 

(shaded area) 

 

 

 

Shown with hood Installed 

(required on all VRT3232 

Series Models)

13”

45°

11”
9”
7”
6”

5”
4”

3”
2”

4”

3”**

5”

6”

7”

8”

10”

12”

14”

16”*

Example

*  Minimum 16” from Side Wall

**No combustible material may be closer than 3”

    from the fireplace opening.

Figure 2a - Minimum Side Clearances to Combustibles

Ceiling clearance: The ceiling must be at least 40" from the top of the 

firebox opening (Figure 2

)

.

Noncombustible material: Noncombustible materials, such as slate and 

marble, must be at least 1/2" thick and may be used without restriction 

above the firebox opening, to the sides or as a hearth extension, so long 

as they do not obstruct vent openings for heat circulating models.

NOTE: To avoid heat-related finish damage, we recommend the use 

of high temperature paint (rated 175° F or higher) on the underside 

of the mantel.

Clearances

Ensure the minimum clearances shown in Figures 2 through 4 are 

maintained. Left and right clearances are determined when facing the 

front of the firebox.

Follow these instructions carefully to ensure safe installation. Failure to 

follow these requirements may create a fire hazard.
Combustible Side Clearances: 

Clearances from the side of the firebox opening to any combustible 

material (e.g. side wall, mantel leg, bookshelf, etc.), must comply with 

the requirements shown in Figures 2 and 2a.
Example

:

 If the mantel leg, bookshelf or other combustible material 

protrudes 5" from the plane of the wall where the firebox is installed, 

the combustible material must be a minimum of 6" from the side of the 

firebox opening 

(see 

Figure 2a

).

Figure 2

Combustible Wall Clearance

Above Appliance (all models)

Figure 3

Top View

Maintain adequate clearances around air openings.

Maintain adequate clearances for accessibility for purposes of servicing 

and proper operation.

Side Wall and Ceiling 

Clearances

Содержание VRT3232WH

Страница 1: ...236WS VRT3242WS VRT3232WH VRT3236WH VRT3242WH WARNING If the information in this manual is not followed exactly a fire or explosion may resultcausingpropertydamage personalinjury or loss of life FOR U...

Страница 2: ...lified service person The heater should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet ing bedd...

Страница 3: ...ON Packaging List Vent Free Gas Firebox Hood Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2approvedDecorative TypeVent F...

Страница 4: ...s a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose...

Страница 5: ...heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Not to Scale Figure 1 CAUTION Do not install in the vicinity where gasoline or other flammable liq uids may be stored...

Страница 6: ...ge we recommend the use of high temperature paint rated 175 F or higher on the underside of the mantel Clearances Ensure the minimum clearances shown in Figures 2 through 4 are maintained Left and rig...

Страница 7: ...rectlyonacombustiblesurface The appliance should be mounted on a fully supported base extending the full width and depth of the unit The appliance may be located on or near conventional construction m...

Страница 8: ...aming or into prepared framing Step2 Plumbgasline Gasconnectionsshould onlybeperformedbyanexperienced licensed certified tradesman Step 3 Install decorative type Vent Free room heater per the instruct...

Страница 9: ...l covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the firebox by checking...

Страница 10: ...RT3242WH 42 1067 27 7 8 708 47 3 4 1213 37 1 4 947 29 1 2 749 20 508 3 77 3 3 16 81 15 7 8 404 7 1 2 191 12 305 1 3 8 35 5 1 2 140 30 3 8 772 29 5 8 753 Top View E F A C Front View Right Side View 2 3...

Страница 11: ...4 Table 1 This Table corresponds to Figures 7 8 and 9 A C D H F G E Rough Framing Face Unfinished Shown Back Wall Of Chase Enclosure Including Finishing Materials If Any Back Wall Of Chase Enclosure I...

Страница 12: ...rebox for safe operation for model VRT3232 series in all installations this part is optional for VRT3236 and VRT3242 models See Figure 11 These hood kits are design to be fitted to the face of the app...

Страница 13: ...fminorscratchesanddiscolorationoftheapplianceblackpaintedsurfaces may be accomplished with the touch up paint kit PA I N T APPROVED ACCESSORIES AND COMPONENTS Outside Air Gate Duct Kit Cat No ModelNo...

Страница 14: ...3 4 5 2 1 6 3 4 5 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or perso...

Страница 15: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 16: ...rth Products IHP reserves the right to make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distrib...

Отзывы: