NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.

12

Figure 11

Hood

Side View

FIREBOX FINISHES

There are a wide variety of “finished looks” for your built-in Vent-Free 

firebox from formal wall decor with elaborate mantels to rustic wood 

paneling or warm brick facings.

Only noncombustible materials like marble, stone, tile, brick, etc. may 

overlap the black front facing.  Seal all joints between the black facing 

and wall surrounds to prevent air intrusion. Use noncombustible caulking 

material only to seal the black metal facing to the surround material on 

the finished wall.  See Figures 3 and 23.

NOTE: No combustible material shall be allowed to 

overlap or contact any section of the front painted face.

HOOD KIT INSTALLATION

The firebox canopy (hood) shall not be modified or replaced with 

a canopy that may be provided with the unvented decorative 

room heater.

NOTE: A hood comes standard and is required for model VRT3232.  

The factory-supplied hood must be installed on the firebox for safe 

operation for model VRT3232 series in all installations (this part is 

optional for VRT3236 and VRT3242 models).  See 

Figure 11

.

These hood kits are design to be fitted to the face of the appliance directly 

above the firebox opening.  In addition to providing an aesthetically pleasing 

appearance to your appliance, the hood reduces heat effects to decora-

tive mantels and finish materials located directly above the fireplace and 

reduces the Mantel / Trim clearances (see Figure 4 on Page 7

).

Please read this entire manual and understood thoroughly before proceed-

ing with the installation of these kits. 

Step 1. Using a 5/16" nut driver or socket, remove the screen and rod 

assemblies as shown in Figure 10.

Step 2. Align the hood with the holes in the side frames as shown in 

Figure 11.  Install three screws as shown in Figure 11. Make 

sure hood is level and secure.

Step 3. Reinstall screen and rod assemblies

 (see

 Figure 10

).

Figure 10

Removing Screens and Rods:

Remove screws (see dotted 

lines). Pull out rods from 

locating holes on side of firebox 

opening.

Reinstalling Screens and Rods:

Insert rods into corresponding 

locating holes on sides of firebox 

opening, then reinstall screws 

as shown.

Содержание VRT3232WH

Страница 1: ...236WS VRT3242WS VRT3232WH VRT3236WH VRT3242WH WARNING If the information in this manual is not followed exactly a fire or explosion may resultcausingpropertydamage personalinjury or loss of life FOR U...

Страница 2: ...lified service person The heater should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet ing bedd...

Страница 3: ...ON Packaging List Vent Free Gas Firebox Hood Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2approvedDecorative TypeVent F...

Страница 4: ...s a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose...

Страница 5: ...heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Not to Scale Figure 1 CAUTION Do not install in the vicinity where gasoline or other flammable liq uids may be stored...

Страница 6: ...ge we recommend the use of high temperature paint rated 175 F or higher on the underside of the mantel Clearances Ensure the minimum clearances shown in Figures 2 through 4 are maintained Left and rig...

Страница 7: ...rectlyonacombustiblesurface The appliance should be mounted on a fully supported base extending the full width and depth of the unit The appliance may be located on or near conventional construction m...

Страница 8: ...aming or into prepared framing Step2 Plumbgasline Gasconnectionsshould onlybeperformedbyanexperienced licensed certified tradesman Step 3 Install decorative type Vent Free room heater per the instruct...

Страница 9: ...l covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the firebox by checking...

Страница 10: ...RT3242WH 42 1067 27 7 8 708 47 3 4 1213 37 1 4 947 29 1 2 749 20 508 3 77 3 3 16 81 15 7 8 404 7 1 2 191 12 305 1 3 8 35 5 1 2 140 30 3 8 772 29 5 8 753 Top View E F A C Front View Right Side View 2 3...

Страница 11: ...4 Table 1 This Table corresponds to Figures 7 8 and 9 A C D H F G E Rough Framing Face Unfinished Shown Back Wall Of Chase Enclosure Including Finishing Materials If Any Back Wall Of Chase Enclosure I...

Страница 12: ...rebox for safe operation for model VRT3232 series in all installations this part is optional for VRT3236 and VRT3242 models See Figure 11 These hood kits are design to be fitted to the face of the app...

Страница 13: ...fminorscratchesanddiscolorationoftheapplianceblackpaintedsurfaces may be accomplished with the touch up paint kit PA I N T APPROVED ACCESSORIES AND COMPONENTS Outside Air Gate Duct Kit Cat No ModelNo...

Страница 14: ...3 4 5 2 1 6 3 4 5 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or perso...

Страница 15: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 16: ...rth Products IHP reserves the right to make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distrib...

Отзывы: