NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

CLEARANCE SPECIFICATIONS

Figure 

4

FP

= FIREPLACE OPENING

X

= AIR SUPPLY INLET

= AREA WHERE FIREPLACE IS NOT PERMITTED

FP

(See Note 2)

D

L

A

H

M

X

J or K

I

G

F

FP

FP

FP

FP

FP

B

B

B

=  2 in. . . . . . . . . .  clearances above grade, 

veranda, porch, deck or 

balcony.

=  12 in. . . . . . . . . .  clearances to window or door 

that may be opened, or to 

permanently closed window.

36 in. . . . . . . . . .  vinyl windows or siding.

=  47 in. . . . . . . . . .  vertical clearance to unventi-

lated soffit or to ventilated soffit 

located above the fireplace.

 

  60 in. . . . . . . . . .  vinyl clad soffits.

=  9 in. . . . . . . . . .  clearance to outside corner.

=  6 in. . . . . . . . . .  clearance to inside corner.

 

  48 in. . . . . . . . . .  vinyl windows or siding.

3 ft. (Canada) .  not to be installed above a gas 

meter/regulator assembly within 

3 ft (914 mm) horizontally from 

the center line of the regulator.

3 ft. (USA)

6 ft. (Canada)

clearance to service regulator 

vent outlet and electric service.

=  9 in. (USA)

 

  12 in. (Canada)

clearance to non-mechanical air 

supply inlet to building or the 

combustion air inlet to any other 

appliance.

3 ft. (USA)

 

 

6 ft. (Canada)  

clearance to a mechanical air 

supply inlet.

L*  =  54 in. . . . . . . . . .  clearance above paved sidewalk

 

 (See note 1) 

or a paved driveway located on 

public

 property.

M**  =  47 in. . . . . . . . . .  clearance under veranda, porch, 

deck, balcony or overhang.

 

 Not allowed: . . . . . .  vinyl.

=  92 in.

  * 

A fireplace shall not open directly above a sidewalk or paved 

driveway which is located between two single family dwellings 

and services both dwellings.

 ** 

Only permitted if veranda, porch, deck or balcony is fully open 

on a minimum of 2 sides beneath the floor, or if the screened 

porch guidelines are followed.

Note 1: 

Local codes or regulations may require different clearances.

Note 2: 

Fireplaces in an alcove space (spaces open only on one 

side and with an overhang) are permitted with the dimensions 

specified for vinyl or non-vinyl siding and soffits. 

1)

 There must 

be  a  3  ft  minimum  between  terminations  or  between  the 

fireplace and termination. 

2)

 All mechanical air intakes within 

10 ft of the top of the fireplace opening must be a minimum of 

3 ft below the top of the fireplace opening. 

3)

 All gravity air intakes within 3 ft of the fireplace must 

be a minimum of 1 ft below the face top opening.

This fireplace is approved for installation in screened porches with the 

following guidelines:

 

Minimum porch area - 96 sq ft

 

Minimum ceiling height - 92 in.

 

Minimum of two walls must be screened or open

 

Minimum top of screen height, side walls - 6 ft 8 in.

 

Minimum screen area - 64 sq ft

Note: 

There may be some odor and small amounts of soot associated 

with  burning  the  fireplace  in  a  screened  porch.  Ensuring  good  cross 

draft ventilation and routine maintenance of the fireplace will maximize 

comfort and cleanliness.

 . . . . 

 . . . . 

=  72 in.

=  72 in. . . . . . . . . .  clearance below an 

opperable window. 

.

 . . . . 

C

P

G

Q

A

Содержание VRE4336ZEN

Страница 1: ...i vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le four...

Страница 2: ...absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CAN CGA B149 1 or Propane Storage and Handling Code B149 2 as applicable The...

Страница 3: ...92 centime ters in length The individual manual shut off must be a T handle type valve Unvented appliances may NOT be in stalled in bedrooms or bathrooms A working smoke detector must be in stalled i...

Страница 4: ...ip pan see Waterproofing The Fireplace and Figure 2 on Page 5 4 Plumb gas line Gas connections should only be performed by an experienced licensed certified tradesman 5 Complete the installation finis...

Страница 5: ...loor 0 0mm adja centwall6 152mm ceiling 72 1829mm Refer to Figure 3 on this page and Figure 21 on Page 14 for more detail NOTE Clearance behind the nailing flange for both fireplace models is 1 2 13mm...

Страница 6: ...shall not open directly above a sidewalk or paved driveway which is located between two single family dwellings and services both dwellings Only permitted if veranda porch deck or balcony is fully ope...

Страница 7: ...infiltration The electrical junction box must be positioned within range of the electrical umbili cal cord 9 feet Route the umbilical cord to the box to ensure proper length Secure the umbilicalcordp...

Страница 8: ...nches millimeters Model No A B C 37 940 41 3 4 1061 23 1 2 597 43 1092 47 3 4 1213 29 1 2 749 1 3 4 28 1 2 724 41 3 8 1051 34 1 4 870 5 127 20 508 12 305 4 3 8 111 Left Side Gas Inlet 8 1 4 210 2 51 M...

Страница 9: ...cluding Finishing Materials If Any Rough Framing Face Unfinished Shown C G A Parallel Installation Rough Framing Face Unfinished Shown Back Wall Of Chase Enclosure Including Finished Materials If Any...

Страница 10: ...ATION AFTER SERVICING Refer to Figure 11 for the wiring schematic for these fireplaces This fireplace is completely wired internally On the right hand side of the fireplace at the rear are four 4 wire...

Страница 11: ...priate toolsandsealingcompounds ensurepropane resistant compounds are used in propane applications Turn on gas supply and test for gas leaks us ing a gas leak test solution also referred to as bubble...

Страница 12: ...t you find most desirable INSTALLING THE LOGS WARNING LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF HANDLE ONLY WHEN LOGS ARE COOL TURN OFF ALL ELECTRICITY TO THE...

Страница 13: ...be cleaned when cool with a soft brush and small amounts of water If the logs are properly positioned and exces sive sooting conditions exist the air shutter opening on the main burner tube should be...

Страница 14: ...ensorandopenthemainvalve Withinseconds the main burner will light Ensure the igniter lights the pilot The pilot flame should engulf the sensor as shown in Figure 20 ELECTRONIC Pilot Hood Sensor Ignite...

Страница 15: ...ructionsdufabricantetselontouteslesexigencesettousles codes pertinents de l autorit comp tente Assurez vous de bien suivre les instructions dans cette notice pour r duire au minimum le risque d incend...

Страница 16: ...Igniter PROPANE NATURAL Burner Orifice Sizes Elevation 0 4500 feet 0 1372 meters Model Nat Gas drill size inches Propane drill size inches VRE4336 28 1405 47 0785 VRE4342 28 1405 47 0785 Table 7 B Ret...

Страница 17: ...and 21 of these instruc tions respectively The appliance lighting instructions may also be found on the pull outlightinginstructionlabelsattachedtothe gas control valve see Figure 26 WARNING DO NOT PL...

Страница 18: ...led the pan and that the logs are set correctly Switch Cover Weather Seal Orient Batteries Vertically To Fit Within Box Figure 27 Battery Replacement Verify proper operation after servicing S assurer...

Страница 19: ...s H4819 ODGHK42 42 Hood Kit Outdoor Gas Outdoor Weather Cover Cat No Model Description H4647 36 EODC 36 SS Outdoor Weather Cover H4648 42 EODC 42 SS Outdoor Weather Cover Decorative Volcanic Stone Cat...

Страница 20: ...wer to the appliance 8 If applicable Set thermostat to desired setting Turn wall on off switch unit mounted on off switch or remote control switch ON Replace the batteries in the battery holder if use...

Страница 21: ...a pas d odeur de gaz passez l tape suivante 5 Replacez les batteries dans leur support 6 R alimentez en lectricit l appareil en tournant l interrupteur mural la position ON 7 Si l appareil ne se met p...

Страница 22: ...of air F Low voltage Test voltage at the batteries It should be around 2 7 to 3 2 VAC 3 The main burner come ON but then go OFF A Gas supply is turned OFF Turned gas supply to ON B Loose wire connecti...

Страница 23: ...Perform the appropriate appliance checkout procedure detailed in this manual Replacing Volcanic Stone Homeowner Qualified Services Technician Remove old volcanic stone and vacuum the stone placement...

Страница 24: ...12 Corner Post LH H4937 1 H4937 1 13 Corner Post RH H4938 1 H4938 1 14 Stand Off Bracket H2716 4 H2716 4 15 Cover Plate Gas Access H4955 1 H4955 1 16 Log Set H4932 1 H4932 1 17 Screen H4926 2 H4927 2...

Страница 25: ...iption F0511 VRE4336ZEN 36 White Stacked F0512 VRE4336ZEN 36 White Herringbone F0513 VRE4336ZEP 36 White Stacked F0514 VRE4336ZEP 36 White Herringbone F0515 VRE4342ZEN 42 White Stacked F0516 VRE4342ZE...

Страница 26: ...______________________________________ ______________________________________________________ ______________________________________________________ ___________________________________________________...

Страница 27: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 28: ...ppliance uses Dealer name Printed in U S A 2017 Innovative Hearth Products P N 900837 01 REV B 07 2018 IHP reserves the right to make changes at any time without notice in design materials specificati...

Отзывы: