background image

27

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900223-00, Rev. C  02/2018

Innovative Hearth Products

1769 East Lawrence Street • Russellville, AL 35654

Innovative Hearth Products

Superior

®

 Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior

®

 Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The product body, firebox and barrier carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty 

against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year 

Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or 

replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also 

pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND 

LIMITATIONS to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The product body, firebox and barrier carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded 

from this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 

venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a 

particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

10

/14

/20

15

Содержание VRE4336ZEN

Страница 1: ...i vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le four...

Страница 2: ...absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CAN CGA B149 1 or Propane Storage and Handling Code B149 2 as applicable The...

Страница 3: ...92 centime ters in length The individual manual shut off must be a T handle type valve Unvented appliances may NOT be in stalled in bedrooms or bathrooms A working smoke detector must be in stalled i...

Страница 4: ...ip pan see Waterproofing The Fireplace and Figure 2 on Page 5 4 Plumb gas line Gas connections should only be performed by an experienced licensed certified tradesman 5 Complete the installation finis...

Страница 5: ...loor 0 0mm adja centwall6 152mm ceiling 72 1829mm Refer to Figure 3 on this page and Figure 21 on Page 14 for more detail NOTE Clearance behind the nailing flange for both fireplace models is 1 2 13mm...

Страница 6: ...shall not open directly above a sidewalk or paved driveway which is located between two single family dwellings and services both dwellings Only permitted if veranda porch deck or balcony is fully ope...

Страница 7: ...infiltration The electrical junction box must be positioned within range of the electrical umbili cal cord 9 feet Route the umbilical cord to the box to ensure proper length Secure the umbilicalcordp...

Страница 8: ...nches millimeters Model No A B C 37 940 41 3 4 1061 23 1 2 597 43 1092 47 3 4 1213 29 1 2 749 1 3 4 28 1 2 724 41 3 8 1051 34 1 4 870 5 127 20 508 12 305 4 3 8 111 Left Side Gas Inlet 8 1 4 210 2 51 M...

Страница 9: ...cluding Finishing Materials If Any Rough Framing Face Unfinished Shown C G A Parallel Installation Rough Framing Face Unfinished Shown Back Wall Of Chase Enclosure Including Finished Materials If Any...

Страница 10: ...ATION AFTER SERVICING Refer to Figure 11 for the wiring schematic for these fireplaces This fireplace is completely wired internally On the right hand side of the fireplace at the rear are four 4 wire...

Страница 11: ...priate toolsandsealingcompounds ensurepropane resistant compounds are used in propane applications Turn on gas supply and test for gas leaks us ing a gas leak test solution also referred to as bubble...

Страница 12: ...t you find most desirable INSTALLING THE LOGS WARNING LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF HANDLE ONLY WHEN LOGS ARE COOL TURN OFF ALL ELECTRICITY TO THE...

Страница 13: ...be cleaned when cool with a soft brush and small amounts of water If the logs are properly positioned and exces sive sooting conditions exist the air shutter opening on the main burner tube should be...

Страница 14: ...ensorandopenthemainvalve Withinseconds the main burner will light Ensure the igniter lights the pilot The pilot flame should engulf the sensor as shown in Figure 20 ELECTRONIC Pilot Hood Sensor Ignite...

Страница 15: ...ructionsdufabricantetselontouteslesexigencesettousles codes pertinents de l autorit comp tente Assurez vous de bien suivre les instructions dans cette notice pour r duire au minimum le risque d incend...

Страница 16: ...Igniter PROPANE NATURAL Burner Orifice Sizes Elevation 0 4500 feet 0 1372 meters Model Nat Gas drill size inches Propane drill size inches VRE4336 28 1405 47 0785 VRE4342 28 1405 47 0785 Table 7 B Ret...

Страница 17: ...and 21 of these instruc tions respectively The appliance lighting instructions may also be found on the pull outlightinginstructionlabelsattachedtothe gas control valve see Figure 26 WARNING DO NOT PL...

Страница 18: ...led the pan and that the logs are set correctly Switch Cover Weather Seal Orient Batteries Vertically To Fit Within Box Figure 27 Battery Replacement Verify proper operation after servicing S assurer...

Страница 19: ...s H4819 ODGHK42 42 Hood Kit Outdoor Gas Outdoor Weather Cover Cat No Model Description H4647 36 EODC 36 SS Outdoor Weather Cover H4648 42 EODC 42 SS Outdoor Weather Cover Decorative Volcanic Stone Cat...

Страница 20: ...wer to the appliance 8 If applicable Set thermostat to desired setting Turn wall on off switch unit mounted on off switch or remote control switch ON Replace the batteries in the battery holder if use...

Страница 21: ...a pas d odeur de gaz passez l tape suivante 5 Replacez les batteries dans leur support 6 R alimentez en lectricit l appareil en tournant l interrupteur mural la position ON 7 Si l appareil ne se met p...

Страница 22: ...of air F Low voltage Test voltage at the batteries It should be around 2 7 to 3 2 VAC 3 The main burner come ON but then go OFF A Gas supply is turned OFF Turned gas supply to ON B Loose wire connecti...

Страница 23: ...Perform the appropriate appliance checkout procedure detailed in this manual Replacing Volcanic Stone Homeowner Qualified Services Technician Remove old volcanic stone and vacuum the stone placement...

Страница 24: ...12 Corner Post LH H4937 1 H4937 1 13 Corner Post RH H4938 1 H4938 1 14 Stand Off Bracket H2716 4 H2716 4 15 Cover Plate Gas Access H4955 1 H4955 1 16 Log Set H4932 1 H4932 1 17 Screen H4926 2 H4927 2...

Страница 25: ...iption F0511 VRE4336ZEN 36 White Stacked F0512 VRE4336ZEN 36 White Herringbone F0513 VRE4336ZEP 36 White Stacked F0514 VRE4336ZEP 36 White Herringbone F0515 VRE4342ZEN 42 White Stacked F0516 VRE4342ZE...

Страница 26: ...______________________________________ ______________________________________________________ ______________________________________________________ ___________________________________________________...

Страница 27: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 28: ...ppliance uses Dealer name Printed in U S A 2017 Innovative Hearth Products P N 900837 01 REV B 07 2018 IHP reserves the right to make changes at any time without notice in design materials specificati...