manualshive.com logo in svg
background image

126817-01F

8

SuperiorFireplaces.us.com

AIR FOR COMBUSTION AND VENTILATION

Continued

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills 
or ducts. You must provide two permanent open-
ings: one within 12" of the ceiling and one within 
12" of the fl oor. Connect these items directly to the 
outdoors or spaces open to the outdoors. These 
spaces include attics and crawl spaces. Follow the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air 
for Combustion and Ventilation

 for required size of 

ventilation grills or ducts. 

IMPORTANT

:

 Do not provide openings for inlet 

or outlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic 
will activate the power vent.

Figure 3 - Ventilation Air from Outdoors

Outlet
Air

Ventilated
Attic 

Outlet
Air

Inlet
Air

Inlet Air

Ventilated 

Crawl Space

To 

Crawl

Space

To Attic

Or

Remove

Door into
Adjoining

Room,
Option

3

Ventilation Grills 

Into Adjoining Room,

Option 2

Ventilation

Grills Into

Adjoining 

Room,

Option 1

12"

12"

INSTALLATION

VENTILATION AIR

Ventilation Air From Inside Building 

This fresh air would come from an adjoining un-
confi ned space. When ventilating to an adjoining 
unconfi ned space, you must provide two permanent 
openings: one within 12" of the ceiling and one 
within 12" of the fl oor on the wall connecting the 
two spaces 

(see options 1 and 2, 

Figure 2

)

. You can 

also remove door into adjoining room 

(see option 3, 

Figure 2

)

. Follow the 

National Fuel Gas Code, ANSI 

Z223.1/NFPA 54, Air for Combustion and Ventila-
tion

 for required size of ventilation grills or ducts.

Figure 2 - Ventilation Air from Inside Building

 WARNING: A qualifi ed service person 

must install appliance. Follow all local 
codes.

NOTICE: State or local codes may only allow 
operation of this appliance in a vented con-
fi guration. Check your state or local codes.

 WARNING: Make sure the selector 

switch is in the OFF position before in-
stalling appliance.

 WARNING: Any outside air ducts and/

or ash dumps in the fi replace shall be 
permanently closed at time of appliance 
installation.

 WARNING: Seal any fresh air vents 

or ash clean-out doors located on fl oor 
or wall of fi replace. If not, drafting may 
cause pilot outage or sooting. Use a heat-
resistant sealant. Do not seal chimney 
fl ue damper. 

NOTICE: This appliance is intended for 
supplemental heating. Use this appliance 
along with your primary heating system. Do 
not install this appliance as your primary 
heat source. If you have a central heating 
system, you may run system’s circulating 
blower while using appliance. This will help 
circulate the heat throughout the house. In 
the event of a power outage, you can use 
this appliance as your primary heat source.

Содержание LTFRS

Страница 1: ...ption DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs This is an unvented gas fired he...

Страница 2: ...for installation only in a solid fuel burning masonry or UL127 factory built fireplace or in a listed ventless firebox enclosure It is design certified for these installations in accordancewithANSIZ2...

Страница 3: ...d adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition Heater will remain hot for a time after shutdown Allow surface to cool bef...

Страница 4: ...Oxygen Depletion Sensing ODS safety shutoff system 1 WARNING This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gase...

Страница 5: ...1 Batterymarch Park Quincy MA 02169 7471 UNPACKING 1 Remove logs and appliance base assembly from carton s COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appliances are approved for installation in...

Страница 6: ...ation classifications 1 Unusually Tight Construction 2 Unconfined Space 3 Confined Space The information on Pages6 8 will help you classify your space and provide adequate ventilation Unusually Tight...

Страница 7: ...r combustion air combustion and ventilation air shall be provided by one of the methods described in the NationalFuelGasCode ANSIZ223 1 NFPA 54 the International Fuel Gas Code or applicable local code...

Страница 8: ...openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 Figure...

Страница 9: ...re to the air Although this is beneficial installing appli ance in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation Page 6 CH...

Страница 10: ...all models If noncombustible material is less than 12 you must install the fireplace hood accessory 24 and 30 Models Only See Figure 5 for minimum clearances Figure 5 Heat Resistant Material Slate Ma...

Страница 11: ...rances Above Combustible Flooring 14 Min Combustible Material Noncombustible Material Hearth 5 Min Combustible Material Determining Minimum Mantel Clearance When Using a Hood If minimum clearances in...

Страница 12: ...ireplace floor to allow access to appliance control panel This will ensure adequate air flow and guard against sooting and controls be ing damaged Raise fireplace floor with noncombustible material Ma...

Страница 13: ...alling in a brick bottom fireplace mark screw locations in mortar joint of bricks 4 Remove appliance base from fireplace 5 Drill holes at marked locations using 3 16 drill bit 6 Attach base through ho...

Страница 14: ...ume to appli ance If pipe is too small undue loss of volume will occur WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas Installation must include an equipment shutoff valve...

Страница 15: ...ening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equipment shut...

Страница 16: ...D RECEIVER WARNING Make sure your selec tor switch is in OFF position before installing or changing batteries in your hand held remote or receiver Hand Held Remote Control The hand held remote control...

Страница 17: ...ddle log 2 and the grate fingers The back of the front left log 3 will rest against the front of the middle log 2 The notch at the end of the front left log 3 will fit around the grate bar See Figure...

Страница 18: ...ole on the bottom of the left top forked log 6 Match the metal pin on teh top of the middle log 2 with the round hold in the bottom of the left top forked log 6 See Figure 26 4 6 5 Metal Pin Rectangul...

Страница 19: ...1 Page 20 Match the round peg on the top of the left top forked log 6 with the round hole on the bottom of the top left log 11 and rectangular peg on the top of the left back top log 5 with the rectan...

Страница 20: ...y logs Only use logs sup plied with appliance or as identified for use with the appliance as shown 1 Place bottom ember log on base assembly as shown in Figure 33 The log should fit over the left side...

Страница 21: ...on the right front log 5 Place the right crossover log onto the rear log and the right front log as shown in Figure 37 The right crossover log has notches in the bottom that will line up with the proj...

Страница 22: ...f plate as shown in Figure 41 Figure 40 Installing Log 1 3 Place the front left log 3 onto the base as sembly between the middle log and the grate The back of the front left log will rest against the...

Страница 23: ...part of the left top back log See Figure 45 Figure 44 Installing Log 5 Figure 45 Installing Log 6 7 Place the right crossover log 7 on top of the middle log and rear log as shown in Figure 46 Match t...

Страница 24: ...mall decorative logs around base of appliance if desired DO NOT place rock or additional logs on front burner or on logs Placing any material on unit other than ember material on front burner may resu...

Страница 25: ...STOP Follow B in the safety information column 1 If you don t smell gas go to the next step 6 Press in and turn control knob counterclock wise to the PILOT position Press in control knob for five 5 se...

Страница 26: ...ob clockwise to the OFF position 2 Set selector switch in the OFF position 3 Close equipment shutoff valve see Figure 14 Page 15 MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 6 under Lighting Ins...

Страница 27: ...Low Battery Hand Held Remote Control When batteries in hand held remote control are low an icon will appear on display Low Battery Remote Receiver When batteries in receiver are low no acoustic signal...

Страница 28: ...on remote control see Figure 56 Page 27 The word ON will appear to the right of temperature bulb graphic on display see Figure 58 Use UP DOWN arrow button to set desired room temperature Control syst...

Страница 29: ...shows an incorrect pilot flame pattern The incorrect pilot flame is not touching the ther mocouple This will cause the thermocouple to cool When the thermocouple cools the appliance will shut down If...

Страница 30: ...s prior to each heating season Blocked air holes will create soot We recommend that you clean the unit every three months during operation and have appliance inspected yearly by a qualified service pe...

Страница 31: ...only 1 Reconnect Igniter cable 2 Free Igniter cable if pinched by any metal or tubing Keep Igniter cable dry 3 Replace Igniter cable 4 Replace Igniter 5 Replace pilot assembly 6 Replace pilot assembly...

Страница 32: ...30 or replace ODS pilot as sembly 6 Hand tighten until snug then tighten 1 4 turn more 7 Replace pilot assembly 8 Replace control valve One or both burners do not light after ODS pilot is lit 1 Inlet...

Страница 33: ...LP gas company 3 Observe minimum installation clearances see Pages 9 11 4 Clean burners see Cleaning and Maintenance Page 30 or replace burner orifice s White powder residue forming within burner box...

Страница 34: ...Stop using odor caus ing products while appliance is running 2 Refill supply tank propane LP only 3 Locate and correct all leaks see Checking Gas Connec tions Page 15 Appliance shuts off in use ODS op...

Страница 35: ...your gas pressure is too low If so contactyourlocalpropane LPornaturalgassupplier TECHNICAL SERVICE You may have further questions about instal lation operation or troubleshooting Please contact your...

Страница 36: ...esult in poor performance and safety hazards VOLCANIC STONE Cat No 80L42 Model FDVS For all models Order when additional volcanic stone is desired EMBER KITS Cat No J6207 Platinum Embers Cat No J6208...

Страница 37: ...8 Warning Plate 1 J3846 Lighting Instruction Plate 1 J3664 Caution Decal 1 J3689 Hardware Kit 1 J5519 Flextube with Fitting TF models only 1 J3656 Fan Switch 1 J3800 Wire Harness 1 Cat No Model F0021...

Страница 38: ...96 Electronic Igniter 1 16 J3571 Igniter Cable 1 17 J4886 Air Shutter 1 18 J5456 Gasket 1 19 J5416 Venturi Tube 1 20 J3547 ODS Nut 2 21 J5200 Natural Gas Air Shutter 1 J5199 Propane LP Gas Air Shutter...

Страница 39: ...M LTF30MM 1 J6405 J6412 J6420 Rear Log 1 1 2 J8178 J6509 J6513 Middle Log 2 1 3 J6407 J6414 J7585 Front Left Log 3 1 4 J8179 J6510 J8219 Front Right Log 4 1 5 J8220 J6511 J6511 Left Top Back Log 5 1 6...

Страница 40: ...isted under Replacement Parts on Page 35 of this manual KEY NO PART NUMBERS DESCRIPTION QTY LTF18 RS LTF24 RS LTF30 RS 1 J6661 J6666 J6666 Bottom Ember Log 1 1 2 J6662 J6667 J6667 Rear Log 2 1 3 J6660...

Страница 41: ...D LTF24WT ID LTF30WT ID 1 F2817 WT 12 F2818 WT 04 F2819 WT 20 Back Bottom Log 1 2 F2820 WT 11 F2821 WT 03 F2822 WT 19 Middle Bottom Log 1 3 F2823 WT 09 F2824 WT 01 F2825 WT 17 Front Left Bottom Log 1...

Страница 42: ..._________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Страница 43: ...produce excessive temperatures and could result in a re hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d dam...

Страница 44: ...your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126817 01 Rev F 12 2019 1769 East Lawrence Street Russellville AL 35654 SuperiorFireplaces us...

Отзывы: