INSTALLATION
Continued
6. Attach
fi
replace to wall studs using nails
or wood screws through holes in nailing
fl
ange
(see Figure 15)
.
Figure 14 - Rough Opening for Installing
in Corner
Figure 15 - Attaching Fireplace to Wall
Studs
Nailing
Flange
Nails or
Wood
Screws
Figure 16 - Minimum Mantel Clearances
for Built-In Installation
7. Check all gas connections for leaks. See
Checking Gas Connections
,
Page 16
.
8. Plug electrical cord into electrical outlet.
9. Install trim after
fi
nal
fi
nishing and/or paint-
ing of wall
(see Figure 7, Page 10)
.
IMPORTANT:
When
fi
nishing your
fi
rebox,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc. may be butted up next to the sides and top
of the
fi
rebox. Combustible materials should
never overlap the
fi
rebox front facing.
WARNING: Do not allow any
combustible materials to overlap
the fi rebox front facing.
IMPORTANT:
Noncombustible materials such
as brick, tile, etc. may overlap the front facing,
but should never cover any necessary open-
ings like louvered slots or screen assembly.
WARNING: Do not allow
noncombustible materials to
cover any necessary openings
like louvered slots.
WARNING: Use only noncom-
bustible mortar or adhesives when
overlapping the front facing with
noncombustible facing material.
*14
1
/
2
"
50
3
/
8
"
71
1
/
4
"
35
5
/
8
"
*14
1
/
2
"
41
1
/
2
"
0" CLEARANCE
FOR 36" MODELS
Figure a
Figure b
Supplied
Firebox Hood
Must Be Used
at All Times
Wire-mesh
Screen
Firebox
Noncombustible
Material May
Project Off this
Surface above
the Firebox Hood
Mantel Shelf
Note: Any portion of the
mantel shelf must NOT
extend beyond this profile.
12" 16" 20"
1
1
/
2
"
6
3
/
4
"
12"
Note: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.
Framing
Material
* THESE DIMENSIONS ALLOW FOR MINIMUM CLEAR-
ANCES TO A 45° PROJECTED SIDE WALL
HOWEVER, CLEARANCES TO PROJECTED MANTEL
TRIMS AND FACINGS ARE ALLOWED WITHIN A MINI-
MUM OF 16" TO A PERPENDICULAR WALL AS SHOWN
IN FIGURE 8, ON Page 11
R
D
0
55
5
/
8
"
39
3
/
8
"
34
1
/
2
"
27
3
/
4
"
0" CLEARANCE
*10
1
/
2
"
*10
1
/
2
"
FOR 32" MODELS