Installation
900697-01 01/2017
Innovative Hearth Products
DRT4000 Series Direct-Vent Gas Fireplaces
20
6.
Rough in the Electrical Supply, if Needed
As necessary, rough in the fireplace electrical supply per NEC and local codes.
7.
Install the [Optional] Blower Kit before Installation in the Framing
1.
Remove the left side blower cover panel screw, and blower cover panel
(see
Table 12, Page 17
)
. Retain the
panel and screw for later reinstallation.
2.
Slide the blower through the opening and position it with the bracket oriented to the front of the firebox and the
blower discharge to the rear of the firebox. Bend the two tabs in the firebox floor to secure the blower to the
floor.
3.
Reinstall the blower cover panel and secure with the removed screw.
4.
Access the blower supply wiring through the front of the fireplace and plug it into the junction box in the right,
rear of the fireplace
(
Figure 32
)
.
5.
Install the blower control switch according to its included instructions.