Installation
900697-01 01/2017
Innovative Hearth Products
DRT4000 Series Direct-Vent Gas Fireplaces
17
Vent Framing—Top Vent
with One 90° Elbow
NOTE:
Dimension “D” is the
required framing depth when
the finish material (drywall)
thickness is 1/2” (13mm).
Inches
(millimeters)
Framing
construction to be
2 x 4, or larger.
B
C
D
A
1/2 A
5-1/8
(130)
7 (178)
12-1/8
(308)
10-1/2
(267)
E
Table 10 - Fireplace Framing Specifications
Model
A *
B
C
D
E
40” Models
40-7/8
(1039)
41-1/4
(1048)
43-3/4
(1111)
22
(559)
28-1/4
(717)
45” Models
45-7/8
(1166)
41-1/4
(1048)
43-3/4
(1111)
22
(559)
28-1/4
(717)
C = Minimum height of top vent installations
E = Minimum height of rear vent installations
* Minimum opening size; additional 1/8” per side is recommended.
NOTE:
Framing specifications do NOT apply for flexible venting.
When using flexible venting, refer to the kit requirements for framing
specifications.
Model
A
B
C
D
E
40”
40-3/8
(1026)
78-1/4
(1988)
55-1/2
(1410)
40-1/2
(1029)
15-7/8
(404)
45”
45-3/8
(1153)
85-7/8
(2182)
61
(1550)
40-1/2
(1029)
17-1/2
(445)
Table 11 - Fireplace Framing Specifications—Corner Installation with Horizontal Termination
Table 12 - Fireplace Specifications
Model
A
B
C
D (door)
E
F
G
H
I
J
K
40” Models
37-1/8 (943)
33-1/4 (845)
27-1/4 (692)
37-3/8 (949)
40-1/4 (1022)
30 (762)
15 (381)
37-7/8 (962)
6-7/8 (175)
21 (534)
12-3/8 (315)
45”Models
37-1/8 (943)
33-1/4 (845)
27-1/4 (692)
42-3/8 (1076)
45-1/4 (1149)
35 (889)
17-1/2 (445)
42-7/8 (1089)
6-7/8 (175)
21 (534)
12-3/8 (315)
NOTE:
When finishing the area around the hood, 5/8” clearance above hood is required for hood installation.
Top View
Front View
Left Side View
Right Side View
A
B
C
D
E
F
G
H
Blower
access panel
Hood
Junction
box access
Gas line
access
I
K
J
K
B
A
C
Inches
(millimeters)
D
E
Back wall of chase/enclosure
(including finishing materials)
7
(178)
Front to rear with 1”
distance to wall
Inches (millimeters)