General Information
900697-01 01/2017
Innovative Hearth Products
DRT4000 Series Direct-Vent Gas Fireplaces
15
Top View of
Fireplace
45
o
At 6” minimum
side wall clearance,
a combustible wall
can project to any
length.
Figure 6 - Combustible Side Clearances
Figure 7 - Mantel Height
Wall Finishes / Surrounds / Mantels
NOTE:
Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined
by the fireplace front face (black sheet metal).
Never allow combustible materials to be positioned in front of or
overlapping the fireplace face
(
Figure 40
).
Non-combustible materials, such as surrounds and other fireplace trim, may be installed on the fireplace face, but they
must not cover any portion of the removable glass panel or control compartment.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel
(
Figure 7
)
. Mantels
constructed of non-combustible materials may be installed at any height above the fireplace opening. However, do
not allow anything to hang below the fireplace hood.
Minimum clearance requirements include any projections such as shelves, window sills, mantels, etc. above the
fireplace.
NOTE:
To avoid heat-related finish damage, we recommend the use of high temperature paint (rated 175° F or higher) on
the underside of the mantel.
INSTALLATION PREPARATION
The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace,
follow these steps:
1.
Remove the shipping carton, and retain the front of the carton (used to protect the fireplace during construction).
2.
Remove the shipping pad, exposing the front glass door.
3.
Remove the glass door
(
Page 56
).
NOTE:
Place the glass door on the shipping carton to protect its surface.
Top View of
Fireplace
45°
Combustible materials allowed
in shaded area “Safe Zone”.
Combustible walls shown in
dark gray
Combustible mantel legs may
project beyond either side of the
fireplace opening as long as they
are kept within the shaded area
illustrated here.
At 6” (153 mm) mini-
mum side wall clear-
ance, a combustible
wall can project to any
length.
6”
(153 mm)
4. IMPORTANT
: Remove the cardboard from beneath
each pressure relief plate
(see
Diagram A
)
. To
remove, squeeze cardboard and pull down (be careful
not to damage the white gasket).
Suggestion
: On
some models, you may wish to remove the baffle (3
screws), for easier access. If removed, reinstall baffle
after cardboard is removed.
Diagram A
Remove Cardboard
(2 places) Before
Using Appliance
12
(305)
10
(254)
8
(203)
6
(152)
4
(102)
2
(51)
in. (mm)
Hood
Fireplace
Mantel depth
12 (305)
14 (356)
16 (406)
18 (457)
20 (508)
22 (559)