9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900301-00 08/2018
Innovative Hearth Products
BRT40ST See-Through B-Vent Gas Fireplaces
*NOTE: 3" (77 mm) above any inclined vent component.
**NOTE: See
Page 11
, Step 1 and
Figure 8
for clearance requirements
to the nailing flange located at each side of the unit and any screw
heads adjacent to it.
Hearth Extension
- A hearth extension is not required with this appliance.
If a hearth extension is used, do not block the lower control compartment
door. Any hearth extension used is for appearance only and does not
have to conform to standard hearth extension installation requirements.
Wall Finishes / Surrounds / Mantels
NOTE:
Combustible wall finish materials and/or surround materials must
not be allowed to encroach the area defined by the appliance front face
(black sheet metal).
Never allow combustible materials to be positioned
in front of or overlapping the appliance face
(see
Figure 6 on Page 9
and Figure 27
on
Page 22
).
Non-combustible materials, such as surrounds and other appliance trim,
may be installed on the appliance face with these exceptions: they must not
cover any portion of the removable glass panel or control compartment.
Vertical installation clearances to combustible mantels vary according
to the depth of the mantel. See
Figure 5
. Mantels constructed of non-
combustible materials may be installed at any height above the appliance
opening; however, do not allow anything to hang below the fireplace hood.
Minimum clearance requirements include any projections such as shelves,
window sills, mantels, etc. above the appliance.
NOTE:
To avoid heat-related finish damage, we recommend the use of high
temperature paint (rated 175° F or higher) on the underside of the mantel.
MINIMUM CLEARANCES TO COMBUSTIBLES
Appliance And Vent Clearances
The appliance is approved with zero clearance to combustible materials
on all sides (as detailed in
Table 5
)
, with the following exception:
When
the unit is installed with one side flush with a wall, the wall on the
other side of the unit must not extend beyond the front edge of the
unit
(see
Figure 2
)
.
MINIMUM CLEARANCES
*
Inches (millimeters)
Back and Sides
1/2" (13)
0 (0) from Spacers Or Dimples **
Top Spacers
0 (0)
Floor
0 (0)
From Bottom of Unit To Ceiling
64 (1626)
Vent
3 (77)
Top
* / 1 (26)
Sides & Bottom
SERVICE CLEARANCES
Feet (meters)
Front, Back, Sides
3 feet (0.9 meters)
Table 5
Figure 6 - Minimum Distance to Unprotected Side Wall
4 (102)
2
(51)
4
(102)
6
(152)
8
(203)
10
(254)
12
(305)
6 (152)
10 (254)
14 (356)
12 (305)
8 (203)
inches (millimeters)
Top of
Appliance
Figure 5 - Minimum Mantel Clearances
Mantel Depth
Front or Rear Face
of Appliance
Min. Distance To
Protected Side Wall
Side
Wall
Side
Wall
Min. Distance To
Unprotected Side Wall
5"
14"
8-1/4"
45°
17"
12"
Combustible Materials Allowed
In Shaded Area Safe Zone
Top View of
Fireplace