35
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Operation
900301-00 08/2018
Innovative Hearth Products
BRT40ST See-Through B-Vent Gas Fireplaces
NOTE: Front Face Assembly with
barrier installed must be rein-
stalled prior to operation.
Front Glass Enclosure Panel, Removal
and Installation
WARNING
Any safety screen or guard
removed for servicing the appli-
ance must be replaced prior to
operating the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré
pour permettre l’entretien de
l’appareil doit être remis en
place avant de mettre l’appareil
en marche.
WARNING
Do not operate appliance with
the glass front removed, cracked
or broken.
AVERTISSEMENT
Ne pas utiliser l'appareil si le
panneau frontal en verre n'est
pas en place, est craqué ou
brisé.
Only doors certified with the appliance
shall be used.
Seules des portes certifiées pour cet
appareil doivent être utilisées.
These are B-vent appliances. They are designed
to operate only when the glass enclosure panels
are installed. Generally the glass enclosure panels
should not be removed except to gain access to
the components within the firebox.
Removing Glass Enclosure Panels
(see
Figure 38
)
To access the glass door securing latches, first
remove the hood by pulling firmly straight away
from the unit. Remove the front face assembly by
lifting up top and bottom evenly approximately
1/2" and pulling straight out from the unit once
the brackets are disengaged.
Remove the bottom compartment door by
sliding the hinge pin, located at the door’s left
side, to the right until it disengages from the
left corner post hole. Pull the door diagonally
to the left, away from the fireplace.
Locate the latch at the top of the control com-
partment and disengage them from the door
frame bottom vee-flange, pulling down on its
handle to open it.
Installing Glass Enclosure Panel
(see
Figure 38)
Retrieve the glass door. Visually inspect the
gasket on the backside of the frame. Gasket
surface must be clean, free of irregularities
and seated firmly.
Position the door in front of the firebox opening
with the bottom of the door held away from the
fireplace
(Figure 38)
. Hook the top flange of the
door frame over the top of the firebox frame.
Let the bottom of the door frame swing gently
in towards the fireplace ensuring that the gasket
seats evenly as the door frame draws shut.
Fasten the latch located underneath the firebox
floor to the door's vee-flange. Close both the
latch securely.
Figure 38
Glass
Door Latch
Front Glass
Enclosure Panel
Firebox Floor
Bottom Vee-flange
Glass Door Frame
Top Flange
Glass Door Frame
NOTE: When installing the glass door, ensure the
spacing on both sides is even and equal.
WARNING
•
Do not attempt to substitute the
materials used on these doors,
or replace cracked or broken
glass.
• Handle this glass with extreme
care! Glass is susceptible to
damage – Do not scratch or
handle roughly while reinstall-
ing the glass door frame.
• The glass door(s) of this appli-
ance must only be replaced as
a complete unit as provided
by the manufacturer. Do not
attempt to replace broken,
cracked or chipped glass sepa-
rately.
•
Do not attempt to touch the
front enclosure glass with your
hands while the fireplace is in
use.
•
DO NOT abuse glass door by
striking or slamming shut.
WARNING
The door should easily close
without needing to be pressed
down. If it has to be pressed
down to close, the gasket in the
top of the door should be dressed