11

9.0. 

RATING

 

 

9.1.  POWER RATINGS

 

The WHR22*S*** Series ratings are shown below: 
 

INPUT: 

VOLTAGE: 

240/120 

   

FREQUENCY:  50/60 Hz 

   

CONNECTION:  1 Phase, 3 Wire 
RANGE: 

-30% to +15% of Selected Output 

OUTPUT: 

VOLTAGE: 

240/120 

   

CONNECTION:  50/60 Hz 

 

Model Number 
(base unit) 

Rated Load 

Max. 
Input 
Amps 

Amps 

kVA at 

240 V 

WHR22WSE12 

42 

10 

60 

WHR22WSF12 

72 

17 

100 

WHR22WSF14 

145 

35 

200 

WHR22WSF16 

215 

50 

300 

WHR22WSF24 

290 

70 

400 

WHR22WSF25 

360 

85 

500 

WHR22WSF26 

430 

100 

600 

WHR22WSF27 

500 

120 

700 

WHR22WSF28 

575 

135 

800 

WHR22WSF29 

650 

150 

900 

WHR22WSF38 

850 

200 

1200 

 

INPUT: 

VOLTAGE: 

240/120 

   

FREQUENCY:  50/60 Hz 

   

CONNECTION:  1 Phase, 3 Wire 
RANGE: 

-20% to +10% of Selected Output 

OUTPUT: 

VOLTAGE: 

240/120 

   

CONNECTION:  50/60 HZ 

 

Model Number 
(base unit) 

Rated Load 

Max. 
Input 
Amps 

Amps 

kVA at 

240 V 

WR22NSD12 

30 

7.2 

37 

WR22NSE12 

50 

12 

60 

WR22NSF12 

80 

19 

100 

WR22NSF14 

160 

38 

200 

WR22NSF16 

240 

57 

300 

WR22NSF24 

320 

75 

400 

WR22NSF25 

400 

95 

500 

WR22NSF26 

480 

115 

600 

WR22NSF27 

560 

130 

700 

WR22NSF28 

640 

150 

800 

WR22NSF29 

720 

175 

900 

WR22NSF38 

960 

225 

1200 

 

 
 
 
 
 
9.2.  VOLTAGE RANGE CHART

 

At the very extremes of the input range the output 
voltage may become slightly higher or lower than would 
  

otherwise be the case. This voltage range chart shows 
the output voltages produced over the input range. 

 

Содержание STABILINE WHR22 Series

Страница 1: ...to make engineering changes on all its products Such refinements may affect information given in the instructions Therefore USE ONLY THE INSTRUCTIONS THAT ARE PACKED WITH THE PRODUCT WARNING High vol...

Страница 2: ...xamine it carefully for any shipping damage The Damage and Shortage instructions packed with the unit outlines the procedure to follow if any parts are missing or damaged 2 0 DESCRIPTION 2 1 GENERAL W...

Страница 3: ...nge S Single Control D Double Control T Triple Control LNN Size Code 3 or 4 digits R Rack Cabinet T Tall Cabinet CB Input Circuit Breaker CS Input Circuit Breaker w 120vac Shunt Trip CR Input Circuit...

Страница 4: ...mum rated current as specified by local and national code requirements The front panel s of the voltage regulator must be removed to allow access to the input and load terminals To remove a panel use...

Страница 5: ...5 2 SETTING OUTPUT VOLTAGE AND SENSITIVITY POTENTIOMETERS Normally the WHR Series voltage regulator should not be operated without the front panel s of the cabinet in place However during the initial...

Страница 6: ...eaker if the coil voltage is lost The trip coil is rated 120 volt AC The coil voltage must be present in order to close the circuit breaker 6 2 1 3 Circuit Breaker Trip Coil Alarm Contacts When alarm...

Страница 7: ...ged the factory settings and did not select the store option the factory setting can be reinstated by pressing both RECALL buttons at the same time The stored factory settings are shown in the table b...

Страница 8: ...ted load current and in some cases the maximum rated nominal input voltage must be reduced Refer to the All Buck and All Boost Rating Chart for the all boost ratings For all boost operation the input...

Страница 9: ...ess the unit is overloaded there is little likelihood of component failure Warning Voltages are present inside this unit which can cause injury Therefore only personnel qualified to service electrical...

Страница 10: ...e motor at the end of travel If the motor operates successfully in this test the problem may be with the control board 8 10 Inspect the POWERSTAT Variable Transformer brush s and commutator s for sign...

Страница 11: ...F38 850 200 1200 INPUT VOLTAGE 240 120 FREQUENCY 50 60 Hz CONNECTION 1 Phase 3 Wire RANGE 20 to 10 of Selected Output OUTPUT VOLTAGE 240 120 CONNECTION 50 60 HZ Model Number base unit Rated Load Max I...

Страница 12: ...ilated enclosures intended for indoor use under usual service conditions Temperature Operating Average ambient temperature for any 24 hour period not to exceed 30 C 86 F and maximum temperature not to...

Страница 13: ...ONTROL MODULE ASSEMBLY A1 Standard Reference Symbol Part Description Part Number A1 CONTROL MODULE 213243 002 A1 A1 CONTROL BOARD 227412 001 A1 F1 F2 F3 F4 FUSE 600V 104364 003 A1 LP1 LP2 LIGHT INDICA...

Страница 14: ...n 10 5 AUX POWER MODULE There is one standard power module used throughout this WHR Series of STABILINE Automatic Voltage Regulators It is used for Line to Line connections Line Line Reference Symbol...

Страница 15: ...15 11 0 SCHEMATIC For reference only use full size supplied with unit...

Страница 16: ...16 12 0 FLOOR MOUNT DIMENSIONS Enclosures A through G Note All dimensions are inches millimeters...

Страница 17: ...17 Enclosures A through G continues Note All dimensions are inches millimeters...

Страница 18: ...18 Enclosures A through G continues Note All dimensions are inches millimeters...

Страница 19: ...19 Enclosures DPLUS through GPLUS Note All dimensions are inches millimeters...

Страница 20: ...20 Enclosures DPLUS through GPLUS continues Note All dimensions are inches millimeters...

Страница 21: ...21 Enclosures DD through GG Note All dimensions are inches millimeters...

Страница 22: ...22 Enclosures DD through GG continues Note All dimensions are inches millimeters...

Страница 23: ...23 Enclosures EEE through GGG Note All dimensions are inches millimeters...

Страница 24: ...24 Enclosures EEE through GGG continues Note All dimensions are inches millimeters...

Страница 25: ...25 13 0 RACK MOUNT DIMENSIONS OPEN Enclosures R1 and R2 Note All dimensions are inches millimeters...

Страница 26: ...hich offer literature technical assistance and a select range of models off the shelf for fastest possible delivery and service In addition Superior Electric Manufacturer s Representatives are availab...

Отзывы: