background image

 

26

 

 

Available Coast-To-Coast and Internationally

 

 

Voltage Control Components 

VOLT-PAC 

®

 

Variable Transformers 

POWERSTAT 

®

 

Variable Transformers 

LUXTROL 

®

 

Lighting Controls 

5-WAY 

®

 

Binding Posts 

SUPERCON 

®

 

Electrical Connectors 

 

Power Quality Solutions 

STABILINE 

®

 

Automatic Voltage Regulators 

STABILINE 

®

 

Transient Voltage Surge 
Suppressors 

STABILINE 

®

 

Uninterruptible Power Supplies 

STABILINE 

®

 

Power Conditioners 

 
 
Voltage Control Components are available worldwide 
through an extensive Authorized Stocking Distributor 
network. These Distributors offer literature, technical 
assistance and a wide range of models off-the-shelf for 
fastest possible delivery and service. 
 
 
STABILINE Power Quality Solutions are available 
worldwide through an extensive Authorized Distributor 
and Reseller network, which offer literature, technical 
assistance and a select range of models off-the-shelf 
for fastest possible delivery and service. 
 
 

 
In addition, Superior Electric Manufacturer’s Representatives are available to provide prompt attention to customer 
needs. Call or fax for ordering and application information or for the address of the closest Manufacturer’s 
Representative, Authorized Distributor or Reseller. 
 
 
 

 

 
 
 
 

Telephone and Fax Numbers 
 
Telephone 

860-507-2025 

Fax: 

860-507-2050 

 
Customer Service: 

860-507-2025 Ext. 70782 

Product Application  860-507-2025 Ext. 72058 

Toll-Free (in U.S.A. and Canada only) 
 
Telephone 

1-800-787-3532 

Fax:  

1-800-821-1369 

 
Customer Service: 

1-800-787-3532 Ext. 70782 

Product Application:  1-800-787-3532 Ext. 70058 
 
 

 
 

One Cowles Road • Plainville, CT 06062 

www.superiorelectric.com 

 
 
 

The right to make engineering refinements on all products is reserved.  Dimensions and other details are subject to change. 

© 2014 

213709-098C manaul WHR22_S (140619).doc

 

An ISO9000 

Registered Company 

Содержание STABILINE WHR22 Series

Страница 1: ...to make engineering changes on all its products Such refinements may affect information given in the instructions Therefore USE ONLY THE INSTRUCTIONS THAT ARE PACKED WITH THE PRODUCT WARNING High vol...

Страница 2: ...xamine it carefully for any shipping damage The Damage and Shortage instructions packed with the unit outlines the procedure to follow if any parts are missing or damaged 2 0 DESCRIPTION 2 1 GENERAL W...

Страница 3: ...nge S Single Control D Double Control T Triple Control LNN Size Code 3 or 4 digits R Rack Cabinet T Tall Cabinet CB Input Circuit Breaker CS Input Circuit Breaker w 120vac Shunt Trip CR Input Circuit...

Страница 4: ...mum rated current as specified by local and national code requirements The front panel s of the voltage regulator must be removed to allow access to the input and load terminals To remove a panel use...

Страница 5: ...5 2 SETTING OUTPUT VOLTAGE AND SENSITIVITY POTENTIOMETERS Normally the WHR Series voltage regulator should not be operated without the front panel s of the cabinet in place However during the initial...

Страница 6: ...eaker if the coil voltage is lost The trip coil is rated 120 volt AC The coil voltage must be present in order to close the circuit breaker 6 2 1 3 Circuit Breaker Trip Coil Alarm Contacts When alarm...

Страница 7: ...ged the factory settings and did not select the store option the factory setting can be reinstated by pressing both RECALL buttons at the same time The stored factory settings are shown in the table b...

Страница 8: ...ted load current and in some cases the maximum rated nominal input voltage must be reduced Refer to the All Buck and All Boost Rating Chart for the all boost ratings For all boost operation the input...

Страница 9: ...ess the unit is overloaded there is little likelihood of component failure Warning Voltages are present inside this unit which can cause injury Therefore only personnel qualified to service electrical...

Страница 10: ...e motor at the end of travel If the motor operates successfully in this test the problem may be with the control board 8 10 Inspect the POWERSTAT Variable Transformer brush s and commutator s for sign...

Страница 11: ...F38 850 200 1200 INPUT VOLTAGE 240 120 FREQUENCY 50 60 Hz CONNECTION 1 Phase 3 Wire RANGE 20 to 10 of Selected Output OUTPUT VOLTAGE 240 120 CONNECTION 50 60 HZ Model Number base unit Rated Load Max I...

Страница 12: ...ilated enclosures intended for indoor use under usual service conditions Temperature Operating Average ambient temperature for any 24 hour period not to exceed 30 C 86 F and maximum temperature not to...

Страница 13: ...ONTROL MODULE ASSEMBLY A1 Standard Reference Symbol Part Description Part Number A1 CONTROL MODULE 213243 002 A1 A1 CONTROL BOARD 227412 001 A1 F1 F2 F3 F4 FUSE 600V 104364 003 A1 LP1 LP2 LIGHT INDICA...

Страница 14: ...n 10 5 AUX POWER MODULE There is one standard power module used throughout this WHR Series of STABILINE Automatic Voltage Regulators It is used for Line to Line connections Line Line Reference Symbol...

Страница 15: ...15 11 0 SCHEMATIC For reference only use full size supplied with unit...

Страница 16: ...16 12 0 FLOOR MOUNT DIMENSIONS Enclosures A through G Note All dimensions are inches millimeters...

Страница 17: ...17 Enclosures A through G continues Note All dimensions are inches millimeters...

Страница 18: ...18 Enclosures A through G continues Note All dimensions are inches millimeters...

Страница 19: ...19 Enclosures DPLUS through GPLUS Note All dimensions are inches millimeters...

Страница 20: ...20 Enclosures DPLUS through GPLUS continues Note All dimensions are inches millimeters...

Страница 21: ...21 Enclosures DD through GG Note All dimensions are inches millimeters...

Страница 22: ...22 Enclosures DD through GG continues Note All dimensions are inches millimeters...

Страница 23: ...23 Enclosures EEE through GGG Note All dimensions are inches millimeters...

Страница 24: ...24 Enclosures EEE through GGG continues Note All dimensions are inches millimeters...

Страница 25: ...25 13 0 RACK MOUNT DIMENSIONS OPEN Enclosures R1 and R2 Note All dimensions are inches millimeters...

Страница 26: ...hich offer literature technical assistance and a select range of models off the shelf for fastest possible delivery and service In addition Superior Electric Manufacturer s Representatives are availab...

Отзывы: