Superabrasive
User Manual
Original Language
Lavina® 30LEU
10/2020
20
8.2 DISMOUNTING/MOUNTING THE GUARD
You can dismount and mount the safe guard
without separating the carriage from the main
head. Put the machine in position to change
the tools. Unscrew the four bolts M5 from the
metal cover preventing the safe guard to fall.
Dismount one of the three holders. Dismount
the safe guard.
8.3 REPLACING POWER CORD AND PLUGS
When replacing the power cord or plugs, always
use cords and plugs with the same specifications
as the original ones. Do not use lower quality or
different types of cords or plugs.
In addition, consider the distance between the appliance and the electrical source. The greater the distance, the greater the resistance and
the less current that will be available at the other end. This will cause a voltage drop and the inverter will switch into alarm mode. This will
also happen if several machines are working on the same line or the generator is not rated for the power needed. In general, our standard
power cable can be doubled in length; longer lengths require replacing all the cables with cables of a larger gauge rate to account for the
length and amperage.
8.4 DISMOUNTING AND MOUNTING TOOL HOLDER TO CHANGING V-RINGS AND FELT-RINGS
To check or replace the buffers and the elastic elements, the tool holders have to be dismounted.
You will need a 13mm deep metric socket with an outside diameter of no more than 3/4in to unscrew the four bolts (Fig.8.4.1) and remove
the holder (Fig.8.4.2). When the tool holder is dismounted, you can change the sealers (V‐Ring and Felt‐Ring).
By loosening four Hex cap flange bolts (Fig.8.4.3) the adaptor comes loose. Unscrew the six screws of the cap (Fig.8.4.4) holding the felt‐
ring. Take out the Felt‐Ring, adaptor and V‐Ring.
Mount the V‐Ring with the smallest lip of the V to the inside (Fig.8.4.5) ‐ simply push the V‐Ring so the top is on the same level as the
pulley top (Fig.8.2.6). Then take the adaptor and push the V‐Ring down with the adaptor (Fig.8.4.7). The lowest lip of the V‐Ring should only
barely touch its gliding surface. Mount the adaptor and the Felt‐Ring on top (Fig.8.4.7). Close the sealers with the cap (Fig.8.4.8) and screw
the bolts. Always use the original bolts. Do not push the V‐ring down with fingers.
Figure 8.4.1
Figure 8.4.2
Figure 8.4.3
Figure 8.4.4
Figure 8.4.5
Figure 8.4.6
Figure 8.4.7
Figure 8.4.8
Figure 8.3
Figure 8.4