Figure 4.7
4.3 ADJUSTING AND MOUNTING TOOLS
Lavina® 30LEU uses tool holder A64. With this new holder every one of our tools uses the “Quickchange” connection. To change
the tools you need first to unlock the butterfly (fig 4.6 in blue) by using the key we provide you (you can see it in the pictures fig.
4.7) remove the security plate (fig 4.6 in red) then load the tools you want and insert the security plate again so the tools cannot
go backwards, rotate and lock the butterfly (as shown in fig.4.7). As you can see in fig. 4.6, for some of the new tools you need to
remove the security plate as they don’t need locking system at all but for the others always make sure that the tools are securely
locked.
In Lavina 30LEU the holder is initially mounted with 3 buffers.
Mount the tools only after ensuring that there is enough diamond bond material left. Be sure that the plates are always clean
before mounting.
WARNING: Always secure the Quick Change tools with the butterfly (Fig.4.6 in blue), lock with the tool holder key
(Fig.4.7) and make sure that the butterfly is securely locked and it holds the security plate not to fall off.
4.4 VACUUM CONNECTION
To connect a vacuum cleaner, the Lavina 30LEU
is supplied with
vacuum hose Cam Lock inlet C250 /
vacuum hose diam. 2, 5
in (63mm)
(Fig.4.8).
Figure 4.8
Figure 4.6