The WARNINGS below indicate a potential 

hazardous situation.  If conditions are not 

avoided a situation could occur that results 

in serious injury or death.

• 

Oxygen  is  not  a  flammable  gas,  but  it 

accelerates the combustion of materials. Do 

not use in explosive atmosphere. To avoid risk 

of fire and explosion the concentrator should 

be  kept away from Flames, Heat sources, 

Incandescent  sources,  Smoking  Materials, 

Matches, Oil, Grease, Solvents, Aerosols, etc.

• 

Use of other accessories not described in this 

User's Guide are not recommended.

• 

• 

No modification to the equipment is allowed. 

• 

Device must have power to operate. In the 

event of power loss and for continued op-

eration a backup source is recommended.

• 

DO NOT disassemble due to danger of 

electrical shock.  Refer servicing to quali

-

fied service personnel.

GENERAL SAFETY GUIDELINES

Only persons who have read and understood this entire manual

 should be allowed to operate the 

O2 concentr

a

tor

 

  

The CAUTIONS below indicate a potentially 

hazardous situation.  If conditions are not 

avoided a situation could occur that results 

in property damage or minor injury or both

.

• 

Use the power cord provided, and check that 

the electrical characteristics of the power 

socket  used  match  those  indicated  on  the 

manufacturer’s  plate  on  the  rear  panel  of 

the device. 

• 

We recommend against the use of extension  

cords  and  adapters,  as  they  are  potential 

sources of sparks and fire.

• 

The  concentrator  has  an  audible  alarm  to 

warn the user of problems. In order that the 

alarm may be heard, the maximum distance 

that the user can move away from it must 

be determined to suit the surrounding  noise 

level.

• 

Do  not  use  in  a  specifically  magnetic 

environment (MRI, X-ray, etc.). May cause 

device malfunction.

• 

This unit may be equipped with a polarized 

plug. That is one blade wider than the other. 

If it does not fit into the outlet, reverse the 

plug. If it still does not fit, contact a qualified 

electrician.  Do not defeat this safety feature.

Содержание Pureline OC4000

Страница 1: ...OC6000 Operators Manual Supera LLC Copyright 2019 OXYGEN CONCENTRATORS For Veterinary Use Only...

Страница 2: ......

Страница 3: ...away for help Our goal is to make your new machine as easy to use and care for as possible This device is meant to be operated under the normal surveillance and control of a veterinarian trained in it...

Страница 4: ......

Страница 5: ...th the 3 16 allen wrench provided VERY tightly 1 Carefully unpack the top assembly and frame from the box 2 Align the top to the frame as shown NOTE The frame base has two cross bars with holes in the...

Страница 6: ...1 Remove the oxygen concentrator from the box and guide the 4 threaded post into the frame 2 Install and tighten the nuts DO NOT OVER TIGHTEN THE NUTS SNUG FIT IS ALL THAT IS NEEDED...

Страница 7: ...Attach the green hose from the OC6000 top to the threaded fitting DO NOT OVER TIGHTEN Oxygen Setup Attach the green hose from your anesthesia machine to the DISS fitting...

Страница 8: ...ch in the AUX position the supply of oxygen to the anesthesia machine comes from E tank on the back of the machine or another source using the E tank adapter p n OC6050 To use the E tank as a souce fo...

Страница 9: ...F power switched off Class II protection Do not expose to open flames Do not use oil or grease Technical information Consult the accompanying documents Keep in the vertical position Fragile handle wit...

Страница 10: ...manual should be allowed to operate the O2 concentrator TheCAUTIONSbelowindicateapotentially hazardous situation If conditions are not avoided a situation could occur that results in property damage o...

Страница 11: ...Concentrator is packaged to protect the device from damage while being transported and stored Check for damage to the packaging After device is removed from the package inspect for damage If damage i...

Страница 12: ...2 1 Front panel Fig 2 1 1 I O ON OFF switch 2 Indicator lights 3 Oxygen product outlet 4 Circuit breaker 5 Pre set flow meter non adjustable...

Страница 13: ...s for ap proximatelyoneminuteafterthedeviceisstopped 1 Filter Silencer 2 Cabinet filter 3 Ventilation grill Note Shown with grate removed Fig 4 1 4 CLEANING MAINTENANCE Only the outside of the concent...

Страница 14: ...he column in production The columns contain a molecular sieve whose function is to adsorbthenitrogenandthusallowoxygentopass The oxygen enriched product is then directed through a pressure reducing va...

Страница 15: ...is fitted on the compressor outlet and is calibrated to 2 7 bar 40 psig 5 4 3 Indicators The green indicator light Fig 5 1 indicates that power is applied to the device When first turned on the indica...

Страница 16: ...he maximum flow does not exceed 10 of the indicated value when a back pressure of 7 kPa 1 psig is applied to the output of the device The maximum outlet pressure is 50 kPa 7 psig 5 5 4 Maintenance of...

Страница 17: ...ubeaxial fan cools the compressor compart ment Environmental limit conditions The performances of the device especially the oxygen concentration are quoted at 21o C 70o F and one atmosphere They may c...

Страница 18: ...Pneumatic connection broken or other pressure problem Internal electrical fault Pneumatic circuit fault Dirty Filters blockage Fan is not working Observations The I O ON OFF button is in the I ON pos...

Страница 19: ......

Страница 20: ......

Страница 21: ...machine This can be washed with mild soap and wa ter DO NOT INSTALL UNTIL 100 DRY P N 8400 1180 Fine inlet filter square black plastic filter List Price 14 95 The fine particle filter goes under the...

Страница 22: ......

Страница 23: ...al applicable for the product 3 products considered to be of a consumable nature such as rubber or plastic goods 4 accessories or parts not manufactured by Supera Anesthesia Innovations 5 specially ma...

Страница 24: ...company s terminal where they are entirely responsible 5 Open and inspect your product as soon as possible DO NOT WAIT 6 If you find damage take as many photographs of everything as soon as you can a...

Страница 25: ...DOCUMENTATION Date purchased Purchased from Machine serial number Machine service information Service Date Service information Service Date Service information Service Date Service information...

Страница 26: ......

Страница 27: ......

Страница 28: ...OXYGEN CONCENTRATORS 503 723 5068 or 877 620 1500 toll free E Mail info superavet com 12330 S E Highway 212 Clackamas OR 97015 www SuperaVet com...

Отзывы: