WATER RECYCLING SYSTEM
Publication: 0028607
5-11
5
9.
Remove and clean the Y-strainer filter element, then
reinstall. (See “Y-Strainer Cleaning” on page 5-6).
10. Drain the recycling supply line.
• Open the drain valve (5) on the elbow of the
charge pump and allow any remaining water to
drain out. Once all the water has drained out,
close the drain valve.
Figure 5-23
• With the vacuum running and the recycling
system off, press the VAC BOOST rocker
switch (6) to generate 18 in-Hg.
Figure 5-24
NOTE
Vacuum pressure can be monitored at the front
control panel HMI screen by pressing the menu
button two times from the home screen.
• Open the drain valve on the elbow of the charge
pump (see Figure 5-23), allowing fresh air to be
sucked in, which will backflush the charge pump
and the oscillating filter screen.
5
6
Содержание Camel 1200 (Dump Body)
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 62: ...1 52 Publication 0028607 SAFETY 1...
Страница 64: ...2 2 Publication 0028607 PRE OPERATION 2 Figure 2 1 Figure 2 2 1 3 2 5 6 4 7...
Страница 106: ...4 18 Publication 0028607 SEWER CLEANING TYPICAL SEQUENCE 4...
Страница 118: ...5 12 Publication 0028607 WATER RECYCLING SYSTEM 5...
Страница 132: ...6 14 Publication 0028607 LUBRICATION AND MAINTENANCE 6...
Страница 156: ...i vi Publication 0028607 IX...
Страница 157: ......