4.3. Preparing the Li-ion battery for use
!
Caution!
Do not operate the Li-ion battery beyond published maximum specifications.
!
Caution!
Charging at deep discharge conditions can lead to venting, excessive heat or
thermal runaway of the cells.
!
Caution!
This Li-ion battery stores fault conditions internally, like excessive charge current or
deep discharge situations. Super B uses this information in the warranty process.
!
Warning!
Do not overcharge the Li-ion battery.
4.3.1. Placement of the Li-ion battery
Before it is used, the Li-ion battery must be positioned in such a way that it will not move
around in its compartment during use. Use appropriate LN5 fastening brackets for mounting.
4.3.2. Set the Li-ion battery in normal operation mode
The Li-ion battery is pre-programmed in storage mode. Before it is used, the Li-ion battery
must be set up in normal operation mode.
The Li-ion battery can be set to normal operation mode by one of the following procedures:
•
Press the S1 Push button for 2 seconds.
•
Connect the Li-ion battery to the charger (see Chapter 5.2 Charging).
•
Charge the Li-ion battery before use.
4.4. Connection wires
Use appropriate wire for the connection wires to prevent overheating and unnecessary
losses. Use appropriate fuses matching the wires and load. Super B suggests to use a
95mm2 connection wires. Connection wires with smaller diameters can cause overheating or
unnecessary losses.