Example 1) I/O   rst address: 0300H

No.

Set value

ON / OFF

SW5

4

L

0

-

-

3

-

-

2

-

-

1

0

ON

SW6

8

M

3

1

OFF

7

1

OFF

6

0

ON

5

0

ON

4

H

0

0

ON

3

0

ON

2

0

ON

1

0

ON

With the above setting, I/O address 0300H to 

034FH are occupied.

I/O   rst address setting switch

Example 2) I/O   rst address: 0F80H

No.

Set value

ON / OFF

SW5

4

L

8

-

-

3

-

-

2

-

-

1

1

OFF

SW6

8

M

F

1

OFF

7

1

OFF

6

1

OFF

5

1

OFF

4

H

0

0

ON

3

0

ON

2

0

ON

1

0

ON

With the above setting, I/O address 0F80H to 

0FCFH are occupied.

I/O   rst address setting switch

Note

I/O address is set in binary notation.

On PC/AT, the internal setting should be [M × 0] · [M × 1] = 1 (M = 3, 7, B, F only)

3) Transmission mode setting switch, I/O control number setting switch (SW2)

This switch sets each system setting. The transmission mode setting switch (SW2-1, SW2-2) per-

forms A mode, B mode and C mode setting. Furthermore, the I/O control number is set with the 
I/O control number setting switch (SW2-5 to SW2-8).

Setting is read in only once when power is supplied to the computer. Changing the mode switch 

setting during operation is ineffective. (The setting cannot be changed with the reset command on 
the 

S-LINK V

 system side.)

Transmission mode setting switch

Transmission
mode

SW2-1

SW2-2

A mode

OFF

OFF

B mode

OFF

ON

C mode

ON

OFF

(A mode)

ON

ON

Transmission mode setting 
switch

I/O control number setting 

switch

(Example)

Transmission mode: B mode

I/O control number: 128 points

I/O control number setting switch

I/O control
number

SW2-5

SW2-6

SW2-7

SW2-8

32 points

OFF

OFF

OFF

OFF

64 points

OFF

OFF

OFF

ON

96 points

OFF

OFF

ON

OFF

128 points

OFF

OFF

ON

ON

160 points

OFF

ON

OFF

OFF

192 points

OFF

ON

OFF

ON

224 points

OFF

ON

ON

OFF

256 points

OFF

ON

ON

ON

288 points

ON

OFF

OFF

OFF

320 points

ON

OFF

OFF

ON

352 points

ON

OFF

ON

OFF

384 points

ON

OFF

ON

ON

416 points

ON

ON

OFF

OFF

448 points

ON

ON

OFF

ON

480 points

ON

ON

ON

OFF

512 points

ON

ON

ON

ON

Содержание SL-VISA

Страница 1: ...CMJE SLVISA No 0006 81V...

Страница 2: ...cable Take care that wrong wiring will damage the product Wiring This product has been developed produced for industrial use only In case noise generating equipment switching regulator inverter motor...

Страница 3: ...d Tightening torque of the terminal screws 0 5 to 0 6 N m Terminal block connector MSTB2 5 7 STF 5 08 with ange Made by Phoenix Contact 2 I O rst address setting switch SW5 SW6 I O rst address setting...

Страница 4: ...rol number is set with the I O control number setting switch SW2 5 to SW2 8 Setting is read in only once when power is supplied to the computer Changing the mode switch setting during operation is ine...

Страница 5: ...d and the connection condition including the addresses where Error 4 has occurred is read again and stored 6 Transmission indicator Green It blinks when communicating during signal transmission with t...

Страница 6: ...or No clear indication Default indication System set indication Interruption indication Busy indication On hold indication Under com mand execution indication Control board Computer R HML0 4B Bank cha...

Страница 7: ...2 HML0 19 207 206 205 204 203 202 201 200 HML0 1A 215 214 213 212 211 210 209 208 HML0 1B 223 222 221 220 219 218 217 216 HML0 1C 231 230 229 228 227 226 225 224 HML0 1D 239 238 237 236 235 234 233 23...

Страница 8: ...ffected S LINK V I O unit is indicated When each bit is 1 the S LINK V I O unit having the allocated address has a cable break or the I O unit is in abnormal condition In case Bank change over respons...

Страница 9: ...uit switches to the bank change over response register and then writes in the bank number User s computer It reads out bank number of the bank change over response register User s computer When the re...

Страница 10: ...When setting is done by a program I Os can be set in units of 16 In this case set all the I O set ting switches to input 0 ON If the change is done by software it is automatically changed within 1 to...

Страница 11: ...t be transmitted After the output data is written if 1 is written into HML0 49 bit 0 and the next output data is written in after con rming that HML0 4A bit 0 has turned to 1 then output data transmis...

Страница 12: ...nding to HML0 49 once and check that the bit corresponding to HML0 4A has turns to 0 prior to the execution 2 System set and Command cannot be executed during an interruption occurrence Only clear anc...

Страница 13: ...or 0 OFF ON when bit 1 is 1 bit 7 6 5 4 3 2 1 0 Assignment Input hold 1 Hold 0 Hold cancel Input change interruption 1 Effective 0 Ineffective Occurrence condition for input change interruption 1 ON O...

Страница 14: ...tsushita Electronic Compo nents Co Ltd 3 Use a local power supply at a cable distance of less than 10m from each I O device Conditions in use for CE conformity Note Do not connect a surge absorber bet...

Страница 15: ...and 1 s pulse width Common 1 000Vp 10ms cycle 1 s pulse width with noise simulator Voltage withstandability Note 5 1 000V AC for one min between external terminals and ground Insulation resistance Not...

Страница 16: ...the delivery of the product 3 Failure caused by a development which could not be foreseen based upon the technology in practice at the time of purchase or contract 4 Failure caused by use which deviat...

Отзывы: