9

2) HML0 + 40: Transmission mode · I/O control points

Transmission mode and I/O control points are stored.

bit

7

6

5

4

3

2

1

0

I/O control points

512 480 448 416 384 352 320 288 256 224 192 160 128 96

64

32

Indication

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

1

0

0

1

1

0

0

1

1

0

0

1

1

0

0

1

1

1

1

0

0

0

0

1

1

1

1

0

0

0

0

1

1

1

1

1

1

1

1

0

0

0

0

0

0

0

0

Transmission mode

A mode

B mode

C mode

Indication

0

1

0

0

0

1

Unused

(= 0)

bit 0 to 3 : I/O control number information is stored.
bit 6, 7  : Transmission mode information is stored.

Note:  No writing is allowed. In order to change the setting, use the dip switches on the board.

3) HML0 + 41 to 44: I/O setting

It sets the I/O assignment of the 

S-LINK V

 I/O units.

Just after power ON / reset of the computer, it indicates the setting condition of “

4) I/O setting 

switch (SW3, SW4)

” in “

3. Functional Description

.”

When setting is done by a program, I/Os can be set in units of 16. In this case, set all the I/O set-
ting switches to input (“0”: ON). (If the change is done by software, it is automatically changed 

within 1 to 2 refresh times.)

bit

7

6

5

4

3

2

1

0

HML0 + 41

HML0 + 42

HML0 + 43

HML0 + 44

Address 0 to 15

Address 128 to 143 Address 256 to 271

Address 384 to 399

Address 16 to 31

Address 144 to 159 Address 272 to 287

Address 400 to 415

Address 32 to 47

Address 160 to 175 Address 288 to 303

Address 416 to 431

Address 48 to 63

Address 176 to 191 Address 304 to 319

Address 432 to 447

Address 64 to 79

Address 192 to 207 Address 320 to 335

Address 448 to 463

Address 80 to 95

Address 208 to 223 Address 336 to 351

Address 464 to 479

Address 96 to 111

Address 224 to 239 Address 352 to 367

Address 480 to 495

Address 112 to 127

Address 240 to 255 Address 368 to 383

Address 496 to 511

0: Input, 1: Output

4) HML0 + 45 to 46: S-LINK V I/O unit connected node number

It shows the number of nodes to which 

S-LINK V

 I/O units are connected. (0 to 256 nodes)

Содержание SL-VISA

Страница 1: ...CMJE SLVISA No 0006 81V...

Страница 2: ...cable Take care that wrong wiring will damage the product Wiring This product has been developed produced for industrial use only In case noise generating equipment switching regulator inverter motor...

Страница 3: ...d Tightening torque of the terminal screws 0 5 to 0 6 N m Terminal block connector MSTB2 5 7 STF 5 08 with ange Made by Phoenix Contact 2 I O rst address setting switch SW5 SW6 I O rst address setting...

Страница 4: ...rol number is set with the I O control number setting switch SW2 5 to SW2 8 Setting is read in only once when power is supplied to the computer Changing the mode switch setting during operation is ine...

Страница 5: ...d and the connection condition including the addresses where Error 4 has occurred is read again and stored 6 Transmission indicator Green It blinks when communicating during signal transmission with t...

Страница 6: ...or No clear indication Default indication System set indication Interruption indication Busy indication On hold indication Under com mand execution indication Control board Computer R HML0 4B Bank cha...

Страница 7: ...2 HML0 19 207 206 205 204 203 202 201 200 HML0 1A 215 214 213 212 211 210 209 208 HML0 1B 223 222 221 220 219 218 217 216 HML0 1C 231 230 229 228 227 226 225 224 HML0 1D 239 238 237 236 235 234 233 23...

Страница 8: ...ffected S LINK V I O unit is indicated When each bit is 1 the S LINK V I O unit having the allocated address has a cable break or the I O unit is in abnormal condition In case Bank change over respons...

Страница 9: ...uit switches to the bank change over response register and then writes in the bank number User s computer It reads out bank number of the bank change over response register User s computer When the re...

Страница 10: ...When setting is done by a program I Os can be set in units of 16 In this case set all the I O set ting switches to input 0 ON If the change is done by software it is automatically changed within 1 to...

Страница 11: ...t be transmitted After the output data is written if 1 is written into HML0 49 bit 0 and the next output data is written in after con rming that HML0 4A bit 0 has turned to 1 then output data transmis...

Страница 12: ...nding to HML0 49 once and check that the bit corresponding to HML0 4A has turns to 0 prior to the execution 2 System set and Command cannot be executed during an interruption occurrence Only clear anc...

Страница 13: ...or 0 OFF ON when bit 1 is 1 bit 7 6 5 4 3 2 1 0 Assignment Input hold 1 Hold 0 Hold cancel Input change interruption 1 Effective 0 Ineffective Occurrence condition for input change interruption 1 ON O...

Страница 14: ...tsushita Electronic Compo nents Co Ltd 3 Use a local power supply at a cable distance of less than 10m from each I O device Conditions in use for CE conformity Note Do not connect a surge absorber bet...

Страница 15: ...and 1 s pulse width Common 1 000Vp 10ms cycle 1 s pulse width with noise simulator Voltage withstandability Note 5 1 000V AC for one min between external terminals and ground Insulation resistance Not...

Страница 16: ...the delivery of the product 3 Failure caused by a development which could not be foreseen based upon the technology in practice at the time of purchase or contract 4 Failure caused by use which deviat...

Отзывы: