CrossFire HP – All-Digital Transport System
User Guide
© SUNWAVE COMMUNICATIONS LIMITED 2015
78
Revision 05
7.3.
7.3.
7.3.
7.3. Channel
Channel
Channel
Channel Gain
Gain
Gain
Gain Adjustment
Adjustment
Adjustment
Adjustment
After setting the channel properties, access the RF signals. In the CrossFire, the nominal downlink input power of the
AU is 0dBm and the maximum allowable input power is 10dBm. Therefore, before accessing the RF signals, estimate the
signal power. Monitor the downlink input power with a spectrum analyzer or read the downlink input power from the
“Digital Info” on the WebOMT in order to set the downlink input power within the appropriate range. The adjustable
attenuation value of each AU channel is 5dB, which can be set in
Engineering
Engineering
Engineering
Engineering
―>
Real-time
Real-time
Real-time
Real-time Info
Info
Info
Info
―>
RF
RF
RF
RF Channel
Channel
Channel
Channel xxxx
.
See Figure 7- 5 for details.
Figure
Figure
Figure
Figure 7
777---- 5555 Channel
Channel
Channel
Channel Gain
Gain
Gain
Gain Adjustment
Adjustment
Adjustment
Adjustment
7.4.
7.4.
7.4.
7.4. Alarm
Alarm
Alarm
Alarm Parameters
Parameters
Parameters
Parameters Setup
Setup
Setup
Setup
After completing the radio-frequency channel properties configuration, set up the alarm parameters using the
following procedure:
1. In the WebOMT, select the
Engineering
Engineering
Engineering
Engineering
tab.
2. Set the status of the optical transceiver one by one.
3. If there is an optical path connection, enable the basic device alarms, such as Power Interruption
Alarm, Battery failure Alarm, MOV Alarm, etc.
For alarms related to channel properties, such as the DPLL unlocked Alarm, LO unlocked Alarm, OP transceiver
failure Alarm, etc., only enable those associated with the channels which have an input signal, to avoid unnecessary
alarms. See Figure 7- 6 for details.
Wait 3~5 minutes after completing the setup, then query to see if there is a failure alarm for the device. If there is